1438

Rewireable Cord Extension Sockets, 10A, suit 1mm² ordinary duty

Catalogue Number: 1438
1438
Colour Transparent (TR)
  • Transparent 1 PCE 1

Specifications

hide show
Range of product
Standard Series
Product brand
Clipsal
Quantity per set
set of 1
Cover type
complete housing
Marking
without marking
Local signalling
without light indicator
[In] rated current
10 A
[Ue] rated operational voltage
250 V AC
Depth
62 mm
Diameter
41 mm
Standards
  • AS/NZS 3112
  • AS 3100
  • AS 3109
  • AS/NZS 3122:approval number S/1
    • EU RoHS Directive
      Compliant
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information

      Frequently Asked Questions

      hide show

      Does Clipsal have a 1438 in 20 amp?

      No, but we have a 438 in 20 amp or there is the 56 series which could do the job.

      For more information, please refer to the link:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=438/20 

      How to use a port other than 1433 for SQL transactions with PME7.2 / SPM7.0.1

      Issue:
      Use a port other than 1433 for SQL transactions with PME7.2 / SPM7.0.1

      Product Line:
      Power Monitoring Expert 7.2.x
      Struxureware Power Monitoring 7.0.x

      Environment:
      Power Monitoring Expert 7.2.x
      Struxureware Power Monitoring 7.0.x

      Cause:
      When port 1433 is blocked or unavailable

      Resolution:

      Port 1433 is the default port used by SQL for all transactions. If port 1433 is blocked and a different port needs to be used, then perform the following steps after installing SQL, but before installing the StruxureWare:

      1. On the application server, create an alias using the SQL Server Client Network utility (start->run->cliconfg) that comes as part of the Windows OS installation.



      2. Click on the Alias tab and then click the Add button



      3. Select TCP/IP, enter the server name, and uncheck "Dynamically determine port"

      4. Change the Port Number to the new port that is is being used (if the new port is 1436, for example, enter 1436 in this field)



      After these steps are completed, running the StruxureWare installer on the Application Server will now connect to the correct port.

      Do you have a 32A version of a 438 extension socket?

      No, the largest rated version of a 438 extension socket is the 438/20 which is 20A.

      Where to find settings manual for MiCOM x3x Series?

      Issue 
      Need more information on settings on the MiCOM x3x.

      Product Line  
      MiCOM P13x
      MiCOM P23x
      MiCOM P43x
      MiCOM P53x
      MiCOM P63x

      Environment  
      Setting or Troubling settings

      Resolution    
      All the settings, measurements, recordings with option and configuration tables plus IEC - 103 telegram documentation/menu database can all be found in the Data Model Explorer.
      To get the Data Model Explorer needed just type in the MiCOM model need.  For example in Google type in MiCOM P438 for Data Model Explorer.  Click on the Schneider Electric result for the MiCOM P438 Data Model Explorer.
      It will bring up the following Data Model Explorer page https://www.schneider-electric.com/en/download/document/P438_DataModelExplorer_EN/
      On the site download the P438 that is needed. 
       

      What is a K1 rating on a dry type Transformer?

      Issue:
      K rated Transformers

      Product Line:
      LV Transformers

      Environment:
      Applies to Low Voltage Transformers by SquareD/Schneider Electric

      Cause:
      K rated Transformers for application on Non Linear loads

      Resolution:
      The Transformer industry does not typically use a `K1` rating.  Rather it is a non-recognized term that some (consultants, OEMs, contractors) use  to denote a Transformer that will only be feeding Linear loads such as motors, compressors, solenoids, heaters, etc.   In other words, K1 refers to a Transformer that does not have a  `K` rating such as K4, K9, K13, K20.        


      CTA-ID : 14386

      We get response buffer too small: 1038 / 1204 in Unity Loader log file ( ULUMAS log file ), what does this error means?

      The log message "response buffer too smal" means that when we upload  from the CPU not all data blocks were uploaded, because some block sizes in the PLC seem to be too big.
      Show More