socket cord ext'n 10a 250v

Rewireable Cord Extension Sockets, 10A, suit 1mm² ordinary duty

Catalogue Number: 1438
socket cord ext'n 10a 250v
Colour Transparent (TR)
  • Transparent 1 PCE 1

Specifications

hide show
Range of product
Standard Series
Product brand
Clipsal
Quantity per set
set of 1
Cover type
complete housing
Marking
without marking
Local signalling
without light indicator
[In] rated current
10 A
[Ue] rated operational voltage
250 V AC
Depth
62 mm
Diameter
41 mm
Standards
  • AS/NZS 3112
  • AS 3100
  • AS 3109
  • AS/NZS 3122:approval number S/1
    • Unit Type of Package 1
      PCE
      Number of Units in Package 1
      1
      Package 1 Weight
      48.3 g
      Package 1 Height
      50 mm
      Package 1 width
      70 mm
      Package 1 Length
      100 mm
      Unit Type of Package 2
      BB1
      Number of Units in Package 2
      10
      Package 2 Weight
      0.55 kg
      Package 2 Height
      84 mm
      Package 2 width
      126.5 mm
      Package 2 Length
      170 mm
      Unit Type of Package 3
      CAR
      Number of Units in Package 3
      200
      Package 3 Weight
      11 kg
      Package 3 Height
      254 mm
      Package 3 width
      348 mm
      Package 3 Length
      445 mm
      EU RoHS Directive
      Compliant
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information

      Frequently Asked Questions

      hide show

      Does Clipsal have a 1438 in 20 amp?

      No, but we have a 438 in 20 amp or there is the 56 series which could do the job.

      For more information, please refer to the link:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=438/20 

      How to use a port other than 1433 for SQL transactions with PME7.2 / SPM7.0.1

      Issue:
      Use a port other than 1433 for SQL transactions with PME7.2 / SPM7.0.1

      Product Line:
      Power Monitoring Expert 7.2.x
      Struxureware Power Monitoring 7.0.x

      Environment:
      Power Monitoring Expert 7.2.x
      Struxureware Power Monitoring 7.0.x

      Cause:
      When port 1433 is blocked or unavailable

      Resolution:

      Port 1433 is the default port used by SQL for all transactions. If port 1433 is blocked and a different port needs to be used, then perform the following steps after installing SQL, but before installing the StruxureWare:

      1. On the application server, create an alias using the SQL Server Client Network utility (start->run->cliconfg) that comes as part of the Windows OS installation.



      2. Click on the Alias tab and then click the Add button



      3. Select TCP/IP, enter the server name, and uncheck "Dynamically determine port"

      4. Change the Port Number to the new port that is is being used (if the new port is 1436, for example, enter 1436 in this field)



      After these steps are completed, running the StruxureWare installer on the Application Server will now connect to the correct port.

      Do you have a 32A version of a 438 extension socket?

      No, the largest rated version of a 438 extension socket is the 438/20 which is 20A.

      Where to find settings manual for MiCOM x3x Series?

      Issue 
      Need more information on settings on the MiCOM x3x.

      Product Line  
      MiCOM P13x
      MiCOM P23x
      MiCOM P43x
      MiCOM P53x
      MiCOM P63x

      Environment  
      Setting or Troubling settings

      Resolution    
      All the settings, measurements, recordings with option and configuration tables plus IEC - 103 telegram documentation/menu database can all be found in the Data Model Explorer.
      To get the Data Model Explorer needed just type in the MiCOM model need.  For example in Google type in MiCOM P438 for Data Model Explorer.  Click on the Schneider Electric result for the MiCOM P438 Data Model Explorer.
      It will bring up the following Data Model Explorer page https://www.schneider-electric.com/en/download/document/P438_DataModelExplorer_EN/
      On the site download the P438 that is needed. 
       

      What size cable does a LAD7B10 accept?

      Issue:
      Need to know the size cable accepted by the LAD7B10 block.

      Product Line:
      IEC Contactors and starters

      Environment:
      Products sold and used in the United States

      Cause:
      Identifying cabling requirements.

      Resolution:
      It takes either a 1 flexible cable without cable end size 14-8 AWG or 1 flex cable with cable end size 16-12AWG or 1 solid cable without cable end size 16-10 AWG.


       

      Does third-party equipment exist to test the AFCI to determine that it is functioning properly?

      Product Line:
      Circuit Breakers
      QO and Homeline
      AFI and AFCI

      Environment:
      Electrical Distribution Equipment

      Resolution:
      No. So-called AFCI ``testers`` are on the market, but they are not UL listed for testing the function of an AFI circuit breaker. UL 1436 refers to them as ``indicators`` rather than testers, and Square D does not endorse them or recommend their use. They are subject to error in the form of giving a false negative result.

      The UL approved method of testing an AFCI circuit breaker is to press the push-to-test button when installed in an energized load center or panel. This test injects a signal into the AFCI sensor that looks like an arc to the AFCI. A properly functioning AFCI will trip when the test button is pushed.

      Paragraph 31.8.1 of the UL 1436 standard requires the AFCI Indicator markings or instructions to effectively state that the test button on the AFCI circuit breaker demonstrates proper operation.
       
      Show More