Rewireable Cord Extension Sockets, 10A, suit 1mm² ordinary duty

Transparent | Rewireable Cord Extension Sockets, 10A, suit 1mm² ordinary duty

Rewireable Cord Extension Sockets, 10A, suit 1mm² ordinary duty

Item Number: 1438-TR

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Standard Series

Product brand

Clipsal

Sustainable offer status

Green Premium product

Physical

Quantity per set

set of 1

Marking

without marking

Local signalling

without light indicator

[In] rated current

10 A

[Ue] rated operational voltage

250 V AC

Depth

62 mm

Standards

  • AS/NZS 3112
  • AS 3100
  • AS 3109
  • AS/NZS 3122:approval number S/1
    • REACh Regulation

      Free of Substances of Very High Concern above the threshold

      EU RoHS Directive

      Compliant

      Mercury free

      Yes

      RoHS exemption information

      Yes

      China RoHS Regulation

      Product out of China RoHS scope. Substance declaration for your information

      Environmental Disclosure

      ENVPEP1605009

      Others

      Cover type

      complete housing

      Diameter

      41 mm

      Unit Type of Package 1

      PCE

      Number of Units in Package 1

      1

      Package 1 Weight

      48.3 g

      Package 1 Height

      50 mm

      Package 1 width

      70 mm

      Package 1 Length

      100 mm

      Unit Type of Package 2

      BB1

      Number of Units in Package 2

      10

      Package 2 Weight

      0.55 kg

      Package 2 Height

      84 mm

      Package 2 width

      126.5 mm

      Package 2 Length

      170 mm

      Unit Type of Package 3

      CAR

      Number of Units in Package 3

      200

      Package 3 Weight

      11 kg

      Package 3 Height

      254 mm

      Package 3 width

      348 mm

      Package 3 Length

      445 mm
      Show all specifications

      Frequently Asked Questions

      hide show

      What size cable does a LAD7B10 accept?

      Issue:
      Need to know the size cable accepted by the LAD7B10 block.

      Product Line:
      IEC Contactors and starters

      Environment:
      Products sold and used in the United States

      Cause:
      Identifying cabling requirements.

      Resolution:
      It takes either a 1 flexible cable without cable end size 14-8 AWG or 1 flex cable with cable end size 16-12AWG or 1 solid cable without cable end size 16-10 AWG.


       

      Is a line isolation contactor or shunt trip circuit breaker needed with Schneider Electric ATS48 Soft Starters?

      Yes a line isolation contactor or shunt trip circuit breaker is needed with Schneider Electric ATS48 Soft Starters.
      Since the solid-state switches may be incapable of completely blocking the motor power should a fault occur, auxiliary isolation on the line side of the controller is required. Use either a circuit breaker equipped with a shunt trip coil or an electromagnetic contactor. Connect the isolation device to the fault relay of the controller so that it opens the controller power circuit in the event of a controller fault. The isolation device must be capable of interrupting motor locked rotor current.

      See link for further product information:https://www.se.com/au/en/product-range/689-altistart-48/
      soft starter for asynchronous motor - ATS48 - 14.8 A - 230..415 V - 3..15 KW