sock swt sing vert 10a shutt

Socket Outlets Switched Vertical, Standard Size, 250V, 10A

Catalogue Number: 15VS
sock swt sing vert 10a shutt
Colour White Electric (WE)
  • White Electric 1 PCE 1

Specifications

hide show
Product brand
Clipsal
Range of product
Standard Series
Control type
ON/OFF button
Number of gangs
1 gang
Pin number
3
Number of power socket outlets
1
Actuator
  • switch
  • rocker
    • Mounting position
      vertical
      Fixing mode
      by screws
      Local signalling
      without light indicator
      Material
      PC (polycarbonate)
      Surface finish
      glossy
      [Ue] rated operational voltage
      250 V AC
      [In] rated current
      10 A
      Depth
      14 mm
      Length
      115 mm
      Width
      73 mm
      Fixing center
      84 mm
      Standards
    • AS/NZS 3100
    • AS/NZS 3112
    • AS/NZS 3133
    • AS/NZS 3000:approval number S/1
      • Unit Type of Package 1
        PCE
        Number of Units in Package 1
        1
        Package 1 Weight
        0.082 kg
        Package 1 Height
        14 mm
        Package 1 width
        73 mm
        Package 1 Length
        115 mm
        Unit Type of Package 2
        BB1
        Number of Units in Package 2
        10
        Package 2 Weight
        0.82 kg
        Package 2 Height
        118 mm
        Package 2 width
        148 mm
        Package 2 Length
        167 mm
        Unit Type of Package 3
        CAR
        Number of Units in Package 3
        100
        Package 3 Weight
        8.2 kg
        Package 3 Height
        254 mm
        Package 3 width
        348 mm
        Package 3 Length
        445 mm
        Sustainable offer status
        Green Premium product
        EU RoHS Directive
        Compliant
        Mercury free
        Yes
        RoHS exemption information
        Yes
        China RoHS Regulation
        Product out of China RoHS scope. Substance declaration for your information
        Environmental Disclosure
        ENVPEP120506EN

        Frequently Asked Questions

        hide show

        What is the inrush current of a LC1D40U7 Contactor?

        It is 160VA inrush and 15VA sealed at 50HZ for the LC1D40U7 Contactor.
        For more information see data sheet https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=lc1d40u7

        Do you have a 15S in biege?

        No, the 15S only comes in White Electric and Red.

        Some of the key features are:
        • 1 pole
        • Standard size
        • Safety shutter
        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=15Shttps://www.clipsal.com/Trade/Products/ProductDetail?catno=15S

        What is the maximum DC voltage per pole for TeSys F Range contactors.

        The maximum DC voltage for TeSys F range contactors is 125 Volt per pole. This voltage is applicable for the specification of L/R <= 15ms in DC applications.

        What is the maximum DC voltage per pole for TeSys D range contactors.

        The maximum DC voltage for TeSys D range contactor is 75 Volt per pole. This voltage is applicable for the specification of L/R <= 15ms in DC applications.

        How does the Test Button on the RH99 work?

        When the test push button is activated the switch SW1 is moved on Test position. The measurement of the network is temporarily stopped during 15ms and a sinusoidal signal of 500Hz to simulate a trip is sent to create a current of 100µA inside the resistor R. The signal seen by the toroid sensor is really negligible about the test signal injection.
        During the test signal injection the settings are: Idn = 30mA and tfault = 0.
        At the end of the 15ms delay
        -> if the product trips (TEST OK) the fault LED and the Fault order relay are activated (in case of no trip test only the fault LED is activated). We have to push on the push button Reset to remove the failure create by the test (in case of automatic reset product no action need to remove the failure).
        -> if the product doesn’t trip, no LED, no relay order the TEST is NOK and it means the product doesn’t work.
        After the 15ms of test signal injection the switch SW1 comes back to the measure position and re-starts the monitor of the network with the customer settings (in the front face).
        So if a trip occurs during the test, it will be see directly after the 15ms of test signal injection and it will be impossible to remove the failure state by a push on Reset push button.
         
        The toroids used on the Vigirex range have only one winding inside.   
         
        There is no Calibration procedure for this product. The product is designed to provide the accuracy specified on the catalogue for the product life time.


         

        What is the minimum pulse width or duration required on a IOX or IOC module to register an input status change on the CM4000 series meter?

        Issue
        Minimum pulse or duration required on a IOX or IOC module on a CM4000 series meter

        Product Line
        CM4000 series meter

        Environment
        Hardware Specifications

        Resolution
        The minimal pulse duration per input on the CM4000 IOX or IOC is 15ms when the control power to the meter is DC voltage. For AC voltage to the control power the minimal input pulse duration is 23ms.
        Show More