Socket Outlets Single Horizontal, Skirting Mount, 250V, 10A

White Electric | Socket Outlets Single Horizontal, Skirting Mount, 250V, 10A

Socket Outlets Single Horizontal, Skirting Mount, 250V, 10A

Item Number: 16-WE

Datasheet

Specifications

Design

Range of product

Standard Series

Product or component type

switched socket

Product brand

Clipsal

Surface finish

glossy

Sustainable offer status

Green Premium product

Physical

Control type

ON/OFF button

Number of gangs

1 gang

Pin number

3

Number of power socket outlets

1

Actuator

  • switch
  • rocker
    • Fixing mode

      by screws

      Local signalling

      without light indicator

      Mounting position

      horizontal

      [Ue] rated operational voltage

      250 V AC

      [In] rated current

      10 A

      Depth

      14 mm

      Length

      98 mm

      Width

      45 mm

      Fixing center

      78 mm

      Standards

    • AS/NZS 3100
    • AS/NZS 3112
    • AS/NZS 3133:approval number S/1
      • REACh Regulation

        Free of Substances of Very High Concern above the threshold

        EU RoHS Directive

        Compliant

        Mercury free

        Yes

        RoHS exemption information

        Yes

        China RoHS Regulation

        Product out of China RoHS scope. Substance declaration for your information

        Environmental Disclosure

        ENVPEP120506EN

        Material

        Material

        plastic

        Others

        Unit Type of Package 1

        PCE

        Number of Units in Package 1

        1

        Package 1 Weight

        62 g

        Package 1 Height

        2.5 cm

        Package 1 width

        4.5 cm

        Package 1 Length

        10 cm

        Unit Type of Package 2

        BB1

        Number of Units in Package 2

        10

        Package 2 Weight

        660 g

        Package 2 Height

        7.7 cm

        Package 2 width

        10.5 cm

        Package 2 Length

        19.5 cm

        Package 3 Height

        25 cm
        Show all specifications

        Frequently Asked Questions

        hide show

        What is the maximum motor distance for an Altivar 212?

        Issue:
        Maximum motor distance for an Altivar 212.

        Product Line:
        ATV212

        Environment:
        All serial numbers for ATV212

        Cause:
        N/A

        Resolution:
        The maximum motor cable length is 50m (164ft).  This maximum can be increased with the use of a motor choke.

        What are the causes of an USF fault on ATV61/ATV71 drives?

        Issue:
        Causes of an USF fault on ATV61 drives.

        Product line:
        ATV61, ATV71, Altivar 61, Altuvar 71

        Environment:
        All models

        Cause:
        Undervoltage supply.

        Resolution:
        The USF fault occurs when the DC bus voltage level drops below the threshold set in 1.8 Fault Management > Undervoltage Management > Undervoltage level. 

        For N4, 480V drives at factory setting of 480VAC, the threshold is 430VDC on the DC bus or 304VAC on the line terminals. 
        For M3, 240V drives at factory setting of 260VAC, the threshold is 230VDC on the DC bus or 163VAC on the line terminals.
        For Y, 575V drives at factory setting of 690VAC, the threshold is 571VAC on the DC bus, or 404VAC on the line terminals.

        Recommendations:
        - Measure the the incoming line to line voltages
        - Compare the line voltage to the Mains Voltage as shown under Menu 1.2 Monitoring, and also the measurement of the DC bus voltage.
        - If the standard line voltage is low, you can adjust the Mains voltage setting.
        - Adjust the Undervoltage time out to compensate for line contactors, or add time delay before a fault would occur. 
         

        Video: Firmware upgrade on a PM800, PM5XXX, PM200, PM700, CM4000/T, CM3000 and CM2000 series meters using DLF-3000

        Issue
        How to upgrade the firmware on a PM800, PM5XXX, PM200, PM700, PM600, CM4000/T, CM3000 and CM2000 series (Powerlogic) meter.

        Product Line
        PM600 series power meter
        PM700 series power meter
        PM800 series power meter
        PM5000 series power meter
        CM4000 series power meter
        CM3000 series power meter
        CM2000 series power meter

        Environment
        Firmware Upgrade

        Resolution
        *Warning: The firmware utilities listed here can cause permanent damage to your product if applied incorrectly. Before downloading any firmware updates, verify the firmware you are downloading is appropriate for the specific model number of your product. If you have any doubts, contact Technical Support for guidance.* 

        *Warning: Devices should be disconnected from all monitoring software before performing a firmware upgrade*


        Reference the embedded video and attached documents for detailed instructions when using DLF-3000 to upgrade CM4000, PM800, and PM5000 series meter firmware.

        The attached procedure is specific to upgrading firmware on the PM800 and PM5000 meters, however the concept and guidelines will be similar for the following meter types in the Powerlogic family:
        CM4000 Series
        CM3000 Series
        CM2000 Series
        PM800 Series
        PM600 Series 
        PM5000 Series
        • To upgrade a CM4000/4250, load the firmware files in the following order using DLF-3000:
        1- CM4_DL_XXXXX.fw
        2- CM4_OS_XXXXX.fw
        3- CM4_LL_XXXXX.fw

        If it is a CM4000T, install CVMT_OS_XXXXX.fw after upgrading the CM4_LL_XXXX.fw file.
        • To upgrade CM3000 series, load the firmware files in the following order using DLF-3000:
        1- CM3_DL_XXXXX.fw
        2- CM3_OS_XXXXX.fw
        3- CM3_LL_XXXXX.fw

        Use the following link to download the DLF-3000 software:
        DLF3000 Download

        It is important to note that you need to right click and run DLF3000 as an administrator. 

        The following links is to the latest firmware for a CM4000 Series meter (v16.010) and CM4 CVMT OS_11.210:
        CM4 DL 13.000
        CM4 OS 16.010
        CM4 LL 14.170
        CM4 CVMT OS 11.210

        The following links is to the latest firmware for a CM3000 Series meter (v15.030):
        CM3 DL 12.200
        CM3 OS 15.030
        CM3 LL 14.170

        The following link is to the latest firmware for a CM2000 Series meter (v17.011):
        FA221408

        The following link is to the latest firmware for a PM210 Series meter (v3.150):
        PM210 firmware

        The following link is to the latest firmware for a PM710 Series meter:
        PM710 firmware (V3.150)
        PM750 firmware (V3.160)

        The following link is to the latest firmware for a PM800 Series meter (v12.700):
        PM800 firmware

        The following link is to the latest firmware for a PM600 Series meter:
        PM600 series firmware 
        **NOTE: PM600 series firmware has two options in the above link. Please confirm the correct one is used on your device with the instructions in the link.

        The following link is to the latest firmware for a PM5100 Series meter (v2.1.1 and v2.2.1):
        PM5100 firmware

        Firmware version 2.xx is not compatible with firmware version 1.xx. The following link is to the latest V1.xx firmware for a PM5100 Series meter (v1.5.4 and v1.6.4):
        PM5100 V1 firmware

        The following link is to the latest firmware for a PM5300 Series meter (v2.1.1 and v2.2.1):
        PM5300 firmware

        Firmware version 2.xx is not compatible with firmware version 1.xx.The following link is to the latest V1.xx firmware for a PM5300 Series meter (v1.5.4 and v1.6.4):
        PM5300 V1 firmware

        The following link is to the latest firmware for a PM5560 Series meter that used DLF-3000 for the upgrade (v1.01.0):
        PM5560 firmware

        All future upgrades past v1.01.0 use the FTP server for the upgrade. See the PM5500 User Guide Page 139 or follow FA299853.

        ​More Information: 
        OS-Operating system;
        RS-Reset system;
        DL-Download system;
        LL-Language Library

         

        What is the neutral CT catalog number for a P frame Powerpact breaker?

        Product Line:
        Circuit Breakers
        PowerPact P

        Environment:
        Electrical Distribution Equipment

        Resolution:
        Neutral CT`s are as follows:
        S33575 250A
        S33576 400 to 1600A


         

        Do the PM5500 series meters support BACNet MSTP protocol?

        Issue
        Do the PM5500 series meters support BACNet MSTP protocol?

        Product Line
        PM55xx

        Resolution
        The PM5500 series meters do not support BACNet MS/TP (BACNet Serial), these meters only support BACNet IP (over Ethernet)

        Kindly refer to page 54 the PM5500 User Manual for more details on BACNet IP support.

        Are the CA2SK11UE7 and 31168-640-54 the same devices?

        Issue:
        Identify the difference between CA2SK11UE7 and 31168-640-54.

        Product Line:
        TeSys SK IEC stle relays

        Environment:
        TeSys SK IEC stle relays, Industrial Control Relays

        Resolution:
        Yes, these are the same components. CA2SK11UE7 is stocked in France and 31168-640-54 is stocked in North America (primarily used on class 8903 type L lighting contactors with form R6).
         
        Show More