Box Wall 1G STD PTN Concrete

Box Wall 1G STD PTN Concrete

Box Wall 1G STD PTN Concrete

Item Number: 160

Datasheet

Specifications

Design

Product brand

Clipsal

Surface treatment

electro-galvanized

Sustainable offer status

Green Premium product

Physical

Number of gangs

1 gang

Length

97 mm

Width

50 mm

Depth

39 mm

REACh Regulation

Free of Substances of Very High Concern above the threshold

REACh free of SVHC

Yes

EU RoHS Directive

Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free

Yes

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Environmental Disclosure

ENVPEP110719EN

Material

Material

steel

Others

Shape

rectangular

Cable entry number

9

Location of connection

rear

Package 1 Weight

0.143 kg
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • Product Environmental

  • Specifications

Frequently Asked Questions

hide show

Video: Firmware upgrade on a PM800, PM5XXX, PM200, PM700, CM4000/T, CM3000 and CM2000 series meters using DLF-3000

Issue
How to upgrade the firmware on a PM800, PM5XXX, PM200, PM700, PM600, CM4000/T, CM3000 and CM2000 series (Powerlogic) meter.

Product Line
PM600 series power meter
PM700 series power meter
PM800 series power meter
PM5000 series power meter
CM4000 series power meter
CM3000 series power meter
CM2000 series power meter

Environment
Firmware Upgrade

Resolution
*Warning: The firmware utilities listed here can cause permanent damage to your product if applied incorrectly. Before downloading any firmware updates, verify the firmware you are downloading is appropriate for the specific model number of your product. If you have any doubts, contact Technical Support for guidance.* 

*Warning: Devices should be disconnected from all monitoring software before performing a firmware upgrade*


Reference the embedded video and attached documents for detailed instructions when using DLF-3000 to upgrade CM4000, PM800, and PM5000 series meter firmware.

The attached procedure is specific to upgrading firmware on the PM800 and PM5000 meters, however the concept and guidelines will be similar for the following meter types in the Powerlogic family:
CM4000 Series
CM3000 Series
CM2000 Series
PM800 Series
PM600 Series 
PM5000 Series
  • To upgrade a CM4000/4250, load the firmware files in the following order using DLF-3000:
1- CM4_DL_XXXXX.fw
2- CM4_OS_XXXXX.fw
3- CM4_LL_XXXXX.fw

If it is a CM4000T, install CVMT_OS_XXXXX.fw after upgrading the CM4_LL_XXXX.fw file.
  • To upgrade CM3000 series, load the firmware files in the following order using DLF-3000:
1- CM3_DL_XXXXX.fw
2- CM3_OS_XXXXX.fw
3- CM3_LL_XXXXX.fw

Use the following link to download the DLF-3000 software:
DLF3000 Download

It is important to note that you need to right click and run DLF3000 as an administrator. 

The following links is to the latest firmware for a CM4000 Series meter (v16.010) and CM4 CVMT OS_11.210:
CM4 DL 13.000
CM4 OS 16.010
CM4 LL 14.170
CM4 CVMT OS 11.210

The following links is to the latest firmware for a CM3000 Series meter (v15.030):
CM3 DL 12.200
CM3 OS 15.030
CM3 LL 14.170

The following link is to the latest firmware for a CM2000 Series meter (v17.011):
FA221408

The following link is to the latest firmware for a PM210 Series meter (v3.150):
PM210 firmware

The following link is to the latest firmware for a PM710 Series meter:
PM710 firmware (V3.150)
PM750 firmware (V3.160)

The following link is to the latest firmware for a PM800 Series meter (v12.700):
PM800 firmware

The following link is to the latest firmware for a PM600 Series meter:
PM600 series firmware 
**NOTE: PM600 series firmware has two options in the above link. Please confirm the correct one is used on your device with the instructions in the link.

The following link is to the latest firmware for a PM5100 Series meter (v2.1.1 and v2.2.1):
PM5100 firmware

Firmware version 2.xx is not compatible with firmware version 1.xx. The following link is to the latest V1.xx firmware for a PM5100 Series meter (v1.5.4 and v1.6.4):
PM5100 V1 firmware

The following link is to the latest firmware for a PM5300 Series meter (v2.1.1 and v2.2.1):
PM5300 firmware

Firmware version 2.xx is not compatible with firmware version 1.xx.The following link is to the latest V1.xx firmware for a PM5300 Series meter (v1.5.4 and v1.6.4):
PM5300 V1 firmware

The following link is to the latest firmware for a PM5560 Series meter that used DLF-3000 for the upgrade (v1.01.0):
PM5560 firmware

All future upgrades past v1.01.0 use the FTP server for the upgrade. See the PM5500 User Guide Page 139 or follow FA299853.

​More Information: 
OS-Operating system;
RS-Reset system;
DL-Download system;
LL-Language Library

 

What is the neutral CT catalog number for a P frame Powerpact breaker?

Product Line:
Circuit Breakers
PowerPact P

Environment:
Electrical Distribution Equipment

Resolution:
Neutral CT`s are as follows:
S33575 250A
S33576 400 to 1600A


 

What are the neutral current transformers used for ground fault sensing NT and NW Masterpact breakers?

Product Line:
NT and NW Masterpact breaker

Resolution:
 
 Table 41:        T-Frame Circuit Breakers
External neutral sensor for 3-phase, 4-wire residual ground fault system (or for neutral current monitoring).
These neutral sensors include their wiring harness. To order this harness as a spare part, order cat. no. NCTWIRING. 
 
NT Circuit Breaker
Sensor Plug
 External Neutral Sensor for general useExternal Neutral Sensor
Square D Panelboard
External Neutral Sensor for use in
Square D Switchboards
  External neutral sensor for circuit breakers with standard neutral protection
100–250 AS33575S33924S33926
400–1600 AS33576S33925S33927
  External neutral sensor for circuit breakers with oversized neutral protection♦
100 AS33575S33924S33926
250 AN/AN/AN/A
400–1000 AS33576S33925S33927
1200/1250 AS48896N/ANA
1600 AS48182N/ANA
♦Oversized neutral protection = 1.6xIr where Ir = long time pick-up.


Table 42:        W/Y-Frame Circuit Breakers
External neutral sensor for 3-phase, 4-wire residual ground fault system (or for neutral current monitoring) and external sensor for Modified Differential Ground Fault (MDGF) or Source Ground Return (SGR) system.
These neutral sensors include their wiring harness. To order this harness as a spare part, order cat. no. NCTWIRING.
 
 

Frame
Size
 

Sensor Plug (A)
External Neutral SensorPZ4 External Neutral Sensor
(For use in PZ4 Switchgear)

 
MDGF/ SGR
Sensor►
 
For Residual Ground Fault
For 3-Pole Circuit Breaker with
Oversize Neutral
Protection♦
 
For Residual Ground Fault
For 3-Pole Circuit Breaker with
Oversize Neutral
Protection♦
 





W
100 S48916S48916 S48902S48902 
250N/AN/A
400 


S34036
 
S34036
 


S48903
 

S48903
 



S33579
600/630
800
1000
1200/1250S48896
1600 
S48182
 


N/A
2000S48896
2500 

S48182
 

S48182
3000 
N/A
3200
4000N/A
 



Y
2000 



S48897•
 

S48897•
 

S48898•
 
S48898•
 



S33579
2500
3000 


N/A
3200
4000
5000 
N/A
 S48897•
6000
6300N/A
•Kit includes qty. (2) neutral sensors.
►Four MDGF sensors (phase + 1 neutral) are required for W-frame; eight MDGF sensors are required for Y-frame. For SGR system, only one sensor (neutral) is required for W-frame; two sensors for Y-Frame.
        An MDGF/SGR ground fault interface module (Cat. no. S48891) is also required for each circuit breaker. 
♦Oversized neutral protection = 1.6xIr where Ir = long time pick-up.

See catalog 0613DB1607 for more Masterpact parts

What are the replacement spring charging motors for the Masterpact NT and NW?

Product Line:
Masterpact NT, Masterpact NW
 
Environment:
New or existing Masterpact breakers in Square D or OEM equipment

Resolution:
Spring Charging Motor (MCH)
VoltageT-FrameW- & Y-Frame
FixedDrawoutFixedDrawout
AC
48S47391S47461S48207S48522
100–130S47395S47465S48211S48526
200–240S47396S47466S48212S48527
277S47398S47468S48213S48528
380–415S47398S47468S48214S48529
440–480S47400S47470S48215S48530
DC
24–30S47390S47460S48206S48521
48–60S47391S47461S48207S48522
100–130S47392S47462S48208S48523
200–250S47393S47463S48209S48524


See instruction bulletins,
Spring Charging Motor (MCH) for Masterpact® NT, Electrically-operated P-frame and NS630b–NS1600 Circuit Breakers
48049-236-01
Spring-charging Motor (MCH) for Masterpact® NW Circuit Breakers
48049-149-02

NW


NT

Information on Powerpact M, P, and R breaker ratings, accessories, terminations, trip units, trip curves, dimensions, and troubleshooting

Issue:
Technical information on MCCB's and their ratings, accessories, terminations, trip units, trip curves, dimensions, application, and troubleshooting

Product Line:
Circuit Breakers

Environment:
Powerpact M P R circuit breakers

Resolution:
It is possible to find much of the available literature by navigating to it in the Schneider Electric Download Center:
Document Download Center:  https://www.schneider-electric.us/en/download/

To find trip curves, ratings, and technical information on electrical and mechanical accessories and lugs, consult the product catalogs:
Powerpact M/P/R:  0612CT0101

For help with Micrologic trip units and modbus communications for Masterpact and Powerpact P and R circuit breakers, consult instruction manuals:
Powerpact P, R, and Masterpact NW, NT Micrologic™ types 2.0, 3.0 and 5.0 Trip Units, see 48049-207-05
Powerpact P, R, and Masterpact NW, NT Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0A Trip Units, see 48049-136-05
Powerpact P, R, and Masterpact NW, NT Micrologic™ 5.0P and 6.0P Trip Units, see 48049-137-05
Powerpact P, R, and Masterpact NW, NT Micrologic™ 5.0H and 6.0H Trip Units, see 48049-330-03
Modbus™ Communications System for Micrologic™ A, P, and H Trip Units 0613IB1201
Powerpact P, R, and Masterpact NW, NT Micrologic™ Modbus User Guide 0613IB1313  (Contains information about the currently unavailable IFE Ethernet interface)

For selection information for catalog numbers for breakers and accessories, consult the Parts List:
Masterpact NT and NW:  0613DB1607

For troubleshooting help, consult instruction manuals to ensure proper installation and review troubleshooting help sections where applicable.
 

What are the catalog numbers, and where is technical information, for the Masterpact NT/NW Circuit Breakers and Micrologic trip units?

Product Line:
Circuit Breakers:

Environment:
Applies to Masterpact NW and NT Circuit Breakers, and their respective trip units

Resolution:
Some popular documents for Masterpact NW and NT breakers are the following:
0613CT0001     Technical Catalog for Masterpact NT and NW
0613PL0001      Parts List for Masterpact NT and NW (includes catalog numbers for many accessory kits)
48049-330-03   Instruction manual for the x.0H Harmonic trip units 
48049-137-05   Instruction manual for the x.0P Power trip units
48049-136-05   Instruction manual on the x.0A Ammeter trip units
48049-207-05   Instruction manual for the x.0 Standard Trip Units

These documents, along with many others, can be found on the Schneider Electric website in the Download Center:  https://www.schneider-electric.us/en/download/
Show More