box wall deep 1g slide nut

BOX WALL DEEP 1G SLIDE NUT

Catalogue Number: 164/1
box wall deep 1g slide nut
Colour:
Colour: Per UOM Std.
  • 1 PCE 1

Specifications

hide show
Range of product
Series 164
Product brand
Clipsal
Shape
rectangular
Number of gangs
1 gang
Cable entry number
11
Material
steel
Surface treatment
electro-galvanized
Length
97 mm
Width
50 mm
Depth
58 mm
Location of connection
rear
Sustainable offer status
Green Premium product
REACh Regulation
Free of Substances of Very High Concern above the threshold
REACh free of SVHC
Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)
Environmental Disclosure
ENVPEP110719EN
Circularity Profile
N/A

Frequently Asked Questions

hide show

What is the wall box to suit the B8/30/4

 The wall box part number is 164/4

What is the alternate code for a 164/3

There is no plastic box the same size as 164/3, you can use PDL144Mt side by side would do the same

What is the wall box to suit the B4/30/2 ?

 The part number for the wall box is 164/2

What are the dimensions of the 164/5 wall box?

The dimensions of the 164/5 wall box are 234mm wide x 97mm high x 58mm deep.

Some of the key features are:
  • Fixed nut
  • 5 gang
  • Standard size
  • for poured concrete
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=164/5

What is the wall box to suit the B6/30/3 ?

 The part number for the wall box is 164/3

What is the wall box to suit the B10/30/5 ?

 The part number for the wall box 164/5

What is the part number for the replacment to 16451?

The replacement to the 16451 is new part number - METSECT5CC005
For further information please visit the link:
 https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=METSECT5CC005
 
User-added image

What are the dimensions of wall box 164/4 and the part number to suit?

The 164/4 which is the wall box to suit part number B8/30/4.

dimensions  188mm x 97mm x 58 mm

What are the dimensions of wall box to suit 14/30/7

Dimensions of wall box 324mm x 97mm x 58mm Part no 164/7

Is there a 154 C-clip that does thicker than 10mm plasterboard/ gyprock?

Yes the 154/1 does plasterboard/gyprock thickness's between 19-25mm.

Do you have the a longer version of the standard mounting screws for your power points?

Yes the part number for the longer screws is a 355A. They are 50mm long apposed  to the 355 which is 32mm long. Both screws are M3.5 X 0.8 Pitch.

What is the part number for the wall box for the 14/30/7 and dimensions?

The part number for the wall box for the 14/30/7 and dimensions are - 164/7 & dimensions - W324mm x H97mm x D58mm

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=14/30/7

User-added image

What are the dimensions of the wall box to suit the B12/30/6 Multi-Gang Switch?

The wall box to suit the 12/30/6 Multi-Gang Switch is a 164/6.

The dimensions of the wall box is a 164/6 are 278mm(W) X 97mm(H) X 58mm(D).

Some of the key features are:

  • 30 series rocker type
  • B-Style
  • Switch arrangement 6 horizontal and 2 vertical
  • Fascia size: 303 mm Width x 120 mm Height
  • 12 number of switch apertures


For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=B12/30/6

What is the replacement for 16468 CT?

The replacement for 16468 CT is METSECT5MF025
 

What is the replacement for a NC100H 3P 40A 

 The part code 18421

Is the 564/1J clip cable 3 core available in black

No, it is only available in white

What is the current transformers with accuracy class 0.5rated power: 3 VA?

 The part code is 16455

What are dimensions of 157/1?

Dimensions for part number 157/1 is a 94mm x 54mm x 39mm.

What is the surge protection replacement for an old PDL 40kA surge protection

 You can use a 16561

What is the part code for the replacement rubber seal for PDL 14/15 Tuff light

The part code is PDL20/8

Is the junction box 265/1 UV rated?

No it doesn't have a rating as such, however it is UV resistant.

Is part no 224/1 avaialble in Black

Part no 224/1 is not available in Black

for more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=224/1

User-added image

What screws would suit a 265/1-GY.

The part number for the screws would be 265SCREW.

Does the 252/32/2A come in orange?

No, the 252/32/2A only comes in grey.

Is there a version of the ML2164 that the plates are mounted Horizontally?

No, The ML2164 Panels are designed to have vertical plates mounted inside them.

What is the replacement for the Merlin Gerin Current Transformer 16456?

The Part code is METSECT5CC020.
https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=METSECT5CC020

Will ML2025RC10, Medilec RCD protected outlet fit into 157/1 wall box?

Yes, 157/1 can be used as a wallbox to install ML2025RC10.

For further information, please visit

157/1
https://www.clipsal.com/Trade/Products/ProductDetail?catno=157/1


ML2025RC10
https://www.clipsal.com/Trade/Products/ProductDetail?catno=ML2025RC10

What is the galvanised flush box to suit BSL range for prison application

The part code is 157/1

Is there a surface mount floor box available?

We can offer a 224/1

What is the part code for a base only for 16571 surge arrestor, already have cartridges

 Sold only as a complete unit, no part code for base only

What is the current replacement to the 16571

new code
A9L20100 

Is there a C clip for 13mm gyprock as the 154 doesn't fit ?

No, The 154 is designed to suit  up to 12mm and then the 154/1 suits from 19-25mm . If These are not suitable then 155 series may be used

Is the 224/1 have outlets either side?

Yes it houses 2 standard size plates, one either side.

What wall clip is used for Prestige large format plates?

The 154/2 is the clip to suit any Prestige large format plate 115mm x 115mm

Part number for a C clip to suit prestige range?

The part name is 154/2

Do you do the 265/1 in a orange colour?

Yes, we can offer the 265/1 in electric orange. The part number is 265/1-EO.
Some of the key features are:
  • Surface mount
  • Dimension: 77 mm Length x 77 mm Width x 54 mm Height
  • 63.5 mm screw centres C, 63.5 mm screw centres D
  • Weatherproof, full cover plate
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=265/1


 

What is the difference between the Surge Arresters reference 15597 and 16447

The difference between the Surge Arrester references 15597 and 16447 is as follows:

1.) 15597 is a PF20 3Pole Fixed type Type 2 LV Surge Arrester.
2.) 16447 is a PRD20 3Pole Withdrawable type Type 2 LV Surge Arrester. 

Both are suitable to be used in low risk level and for use in TNC Earthing systems.

The difference is that 15597 at its end of life needs to be replaced as it is Fixed type, while 16447 at its end of life can be reused by simply replacing the cartridge as it is Withdrawable type, and the other major advantage is that the wiring does not get disturbed.

What are the dimensions for part number 162/4?

The dimensions are 186mm (w) x 194mm (h) x 58mm (d)

for more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=162/4

User-added image

What is the code for a flush box to suit the 408/3?

408/3 has 84mm mounting centres so can be mounted on standard clipsal flush box like the 157/1 for example.

Do you have a disposable cover for a 157/1 PRM wall box?

Yes, we do have a wall box spacer for the 157/1PRM wall box. The part number is SL2000WBS.

On a 9001KS43B, what are the basic part numbers?

Issue:
On a 9001KS43B, what are the basic part numbers?

Product Line:
Harmony Pushbuttons

Environment:
All Products

Resolution:
The operator only is a 9001KS43, the cam is a 9001K13C, and the knob is a 9001B11.

What is the part number of the wall clip suitable for large format Prestige P2000 plates?

The part number for the wall clip suitable for large format Prestige P2000 plaes is 154/2.

Can the 563/1 connector be used for an earth connection?


No, unfortunately the 563/1 screw connectors are not suitable for an earth connector as the screw is only 67% of the tunnel.
Alternatively you are able to use any of our two screw connectors as they do apply with current rules and regulations of AS3000.
 


I.e. 563/2


Key features:

 

  • 2x 6mm cables
  • Clear insulation
  • 2 Screw

For further information please visit  https://www.clipsal.com/Trade/Products/ProductDetail?catno=563/2 


 


 

 


 

What wall box is required for the Metal plate range BSL25A-WE and BSL31VA-WE?

The 157/1 can be used, but ensure that the wall box is mounted 25mm from outer wall surface.

How many plates fit on the 224/1?

The 224/1 fits 2 standard size plates. This can include GPO's, Multigang data plates, Light switches.

For further information, please visit www.clipsal.com/Trade/Products/ProductDetail?catno=224/1

User-added image

 

- Does the 30USBCM fit into 2025XA and C2025XA

Yes it will fit into 2025XA / C2025XA, with the following mounting hardware only: 154, 154RM, 154/1, 155NAR, 155VNAR, 155PRM, 156/2, 157, 164, 449A. Will not fit SC2025XA / 25XA. ( Also please note that it will need to be placed into plate in vertical configuration)
For more information on the 30USBCM please visit the Clipsal web site or click  link provided .https://www.clipsal.com/Trade/search-results?q=30usbcm

What is the difference between a XB2 and XB4?

Issue:
Need to know what are the changes from XB2 to XB4

Product Line:
Harmony Pushbuttons

Environment:
All Products

Resolution:
The XB4 requires only 1 screw to tighten on the mounting collar verses 2 on the XB2. This allows easier installation. The XB4 push buttons can accept 3 contact blocks side-by-side-by-side for a total of nine contacts on non-illuminated devices. Using the XB4 Protected LED light modules and contacts on each side will allow shallower depth than the XB2 on illuminated devices.
 

What is the C clip bracket for double gyprock roughly 25mm thick? Do you also do long screws to suit?

The part number for the C clip is 154/1.
The Part number for the screws is 355A.

For further information please visit https://www.clipsal.com/Trade

What is the operating temperature of the 563/1 and the 563/2 1 and 2 screw bluepoints?

Our connectors are made of Polypropylene (which is a flame retardant material) according to the supplier this material can hold up top +-165C.
Although I will not recommend more than room temperature + 40C.
Keep in mind cables will not stand such temperature anyway as they normally rated between 75C to 90C

Some of the key features are:
  • Cable Connectors
  • Single or double screw
  • Clear insulated
  • Suits up to 2 x 6mm² cables


 

If the Actuator Power utilized shows up as a warning (yellow), according to the Advantys STB configuration software Resource Analysis, does it mean that the island will not work?

Title

Advantys STB Actuator Power warning message

Issue

 

Product Line

Advantys STB

Environment

 

Cause

 

Resolution

No.  A warning flag will not prevent you from building a project.  This flag is calculated based on the worst case scenario for what the modules can handle.  A more accurate calculation would be to take into account the actual current draw of the field devices being used.  If there is no configuration software, then the calculation would have to be done manually.  Adding another PDT will increase actuator or sensor power.  Also if the current draw is actually above the allowable limit, the PDT fuse(s) will be blown.

 

 