Socket Outlets Double Auto Switch Horizontal, 10A, Single Pole

White Electric | Socket Outlets Double Auto Switch Horizontal, 10A, Single Pole

Socket Outlets Double Auto Switch Horizontal, 10A, Single Pole

Item Number: 20-WE

Datasheet

Specifications

Design

Range of product

Standard Series

Product or component type

socket-outlet

Product brand

Clipsal

Sustainable offer status

Green Premium product

Physical

Quantity per set

set of 2

Marking

without marking

Local signalling

without light indicator

Fixing mode

by screws

[In] rated current

10 A

[Ue] rated operational voltage

250 V AC

Depth

16 mm

Length

115 mm

Width

73 mm

Fixing center

84 mm

Number of poles

1

Standards

  • AS/NZS 3100
  • AS/NZS 3112
  • AS/NZS 3133
  • AS/NZS 3000:approval number S/1

REACh Regulation

Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental Disclosure

ENVPEP120506EN

Others

Cover type

full cover plate

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

104.0 g

Package 1 Height

1.0 cm

Package 1 width

7.0 cm

Package 1 Length

11.0 cm

Unit Type of Package 2

BB1

Number of Units in Package 2

5

Package 2 Weight

582.0 g

Package 2 Height

10.8 cm

Package 2 width

12.7 cm

Package 2 Length

14.5 cm

Unit Type of Package 3

CAR

Number of Units in Package 3

50

Package 3 Weight

5.8 kg

Package 3 Height

15.7 cm

Package 3 width

30.5 cm

Package 3 Length

44.5 cm
Show all specifications

Documents & downloads

hide show

Frequently Asked Questions

hide show

Video: What can be done to reduce electrical noise caused by a Schneider Electric drive?

Issue:
Video: How can the electrical noise level be reduced caused by a Schneider Electric drive?

Product Line:
All drives

Environment:
All

Cause:
PWM output can produce audible high pitched sound when operating normally.

Resolution:
To reduce the noise level, do the following:
- Reduce the switching frequency
- Use shielded cables
- Separate power cables and control cables

 

How to upgrade Micrologic X firmware on Masterpact MTZ ?

Masterpact MTZ ACB use EcoStruxure Power Commission (EPC) software for firmware upgrade, set up, testing & commissioning.
  Also, make sure to follow all the instructions for the firmware upgrade mentioned in the Micrologic X user manual as attached.
The attached document ‘EPC How to Upgrade Firmware’ shows the upgrade process.

Connection using a USB cable
 
 

What is the complete RJ45 connector pinout for ATV320?

The complete pinout, 
Pin 1 = CAN_H
Pin 2 = CAN_L
Pin 3 = CAN_GND
Pin 4 = DI Modbus Signal 
Pin 5 = DO Modbus Signal
Pin 6 - Not connected
Pin 7 = VP, 10Vdc
Pin 8 = Common 

The CANopen signals on the front port are deactivated if an option card is plugged in the drive (any option card connected). 

ATV320 Pinout of the RJ45 connector
 

Why can't I create a project offline with my variable frequency drive with SoMove?

Issue:
 Creating an Offline Project with SoMove

Product Line:
SoMove

Environment:
Build 2.2 and later

Cause:
The most likely cause is that the DTM files need to be downloaded and installed.

Resolution:
Use this link to download the current version of the Altivar and Altistart DTM files for SOMove.

ATV
https://www.schneider-electric.com/ww/en/download/document/Altivar_DTM_Library?showAsIframe=true&xtmc=altivar%20dtm&xtcr=1

ATS
https://www.schneider-electric.com/ww/en/download/document/Altistart_DTM_Library?showAsIframe=true&xtmc=altistart%20dtm&xtcr=1

SoMove Standalone V2.2
https://www.schneider-electric.com/download/ww/en/results/0/0/8336271-SoMove/1555684/?showAsIframe=false

What is the replacement 120 volt coil for a CA2DN131?

Issue:
Is there a 120 volt coil replacement for a CA2DN131?

Product Line:
Relays and Timers

Environment:
Industrial relays

Cause:
Legacy Replacement

Resolution:
This coil is obsolete.  Relay will have to be replaced.  Check the online cross reference for current replacement.  

What are the wire or cable sizes required for the GV7RE and GV7RS starters?

Issue:
For GV7RE and GV7RS starters, what is the wire size recommendation?

Product Line:
Manual starters and protectors

Environment:
Tesys GV2,GV3 and GV7

Cause:
Wiring and installation of starters

Resolution:
For the GV7R*20 thru R*150 use a mechanical lug kit / clip-on connectors for 1 #14-3/0 GV7AC021 (sold in lots of 3) . For the GV7R*220 use a kit for 1 #14-350mcm GV7AC022 (sold in lots of 3).
Show More