SURROUND 2000 SERIES

Catalogue Number: 2000
surround 2000 ser
Colour: White Electric
Colour: Per UOM Std.
  • Beige 1 PCE 1
  • Black 1 PCE 1
  • Dark Blue 1 PCE 1
  • Red 1 PCE 1
  • Silver Plate 1 PCE 1
  • White Electric 1 PCE 1

Specifications

hide show
Range of product
Series 2000
Product brand
Clipsal
Mounting position
horizontal
Device mounting
flush
Material
plastic
Type of installation
indoor
Surface finish
brilliant
Depth
13 mm
Length
116 mm
Width
76 mm

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Product Environmental

  • Installation Instruction

  • Operating Manuals

  • Specifications

  • Certificates (MSDS)

Frequently Asked Questions

hide show

What are the part#'s for the Panelmate Plus Modbus Plus Interface Board?

The part #'s for the Panelmate Plus Modbus Plus Interface Boards are:
1) MM-PMMP001C - Panelmate Plus 2000 / 3000 / 4000 Modbus Plus Interface, CE
2) MM-PMMP002C - Panelmate Plus 2000 / 3000 / 4000, Dual MB+ Interface, CE
3) MM-PMMP003C - Panelmate Plus 1000 / 1500 Modbus Plus Interface, CE

What is the frequency of the internal buzzer used in the Magelis XBTGT 2000 to 7000 series HMI terminals?


The buzzer frequency is between 2000Hz and 2600 Hz. (2300Hz typical)


Legacy KB System (APS) Data: RESL192877 V1.0, Originally authored by MiMe on 10/01/2008, Last Edited by MiMe on 10/01/2008
Related ranges: Magelis XBT G

Is Event Notification Solution 6.4 /Active Pager Module 6.4 (ENS 6.4, APM 6.4) compatible with SQL 2000?

ENS 6.4 is only supported with SQL 2005 and SQL 2008 instances.
During the install, SQL 2000 instances can be chosen, but the install will not complete if a SQL 2000 instance is selected.


Legacy KB System (APS) Data: RESL206608 V1.0, Originally authored by MaTh on 11/09/2011, Last Edited by MaTh on 11/09/2011
Related ranges: Paging Module, SMS Add-on

What is the default password for PowerLogic meters?

Product Lines
CM4000 / CM4
CM3000 / CM3
CM2000 / CM2
PM800 / PM8
PM700 / PM7
PM600 / PM6
PM200 / PM2
EM3500
PM5000 Series
PM8000

Environment
On-board Password

Resolution
The default password is 0000

Does OFS V3.50 supports Windows 8

Yes, OPC v3.5 Factory Server is supported in Windows 8, Server 2012, Windows 7, Server 2008 R2, Vista, XP, 2000, and Server 200. OFS must not be installed on virtual machines.

Sepam EcoFit offer

Schneider Electric offers a retrofit solution for converting Sepam 2000's to the new Sepam 1000+ relays.
ECOFIT S2000 Leaflet - SERED111087EN.pdfECOFIT S2000 Leaflet - SERED111087EN.pdfECOFIT SEPAM 2000 Customer Presentation Rev1a.pptECOFIT SEPAM 2000 Customer Presentation Rev1a.ppt

Can you get a double power point with 2 USB ports?

No, unfortunately this part is unabaliable. However, there is a single power point with 2 USB ports avaliable. This is avaliable in two diffrent styles, 2000 Series or the Classic 2000 Series. The part numbers are (Classic 2000) C2015USB2C and (2000 Series) 2015USB2C.
Some of there key features are:
  • Twin 30USBCM USB Chargers
  • Surge, over-current and over-temperature protection
  • Cable compensation for optimised charging
  • Meets BC1.2 USB Charging Standard
  • Meets Class V Energy Efficiency in standby
  • Certified to all relevant safety and EMC requirements for Australia

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2015USB2C
                                              Or https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2015USB2C

 
 
 

 

What is the wattage rating for Clipsal 501ES

It is 200w for white ones

Is it Possible to Upgrade a 1600A NW16 Breaker to a 2000A NW20 by Changing the Sensor Plug.

No. It is not possible. As per the attached document the NW16 have sensor rating only from 800 - 1600A, So a 2000A Sensor Plug is not suitable for NW16 Breaker. So it can not be changed. 

Can 2000 series and C2000 series, IP66 range of switches be used outdoors?

Clipsal IP66 2000 Series and C2000 Classic series switches are hardwearing, UV stabilised, polycarbonate surface and suitable for a wide variety of outdoor areas, such as carports and pergolas.
For further information, please visit https://updates.clipsal.com/ClipsalOnline/Files/Brochures/A0000083.pdf

What version of SQL Server is used with the different versions of ION Enterprise?

ION Enterprise 3.0 MSDE 1.0 (SQL Server 7.0)
ION Enterprise 4.0 MSDE 1.0 (SQL Server 7.0)

ION Enterprise 4.5 MSDE 1.0 (SQL Server 7.0)

ION Enterprise 5.0 MSDE 2000 (SQL Server 2000)

ION Enterprise 5.5 MSDE 2000 (SQL Server 2000)

NOTE: It is possible to use ION Enterprise 5.5 Service Pack 2 with SQL Server 2005, but some modifications are required. See KB articles 12704, 12708 and 12823 for detailed information.

ION Enterprise 5.6 SQL 2005 Express (SQL Server 2005)
NOTE: ION Enterprise 5.6 will use an existing MSDE 2000 instance, but will install SQL Express on new systems if there is no pre-existing SQL Server instance.
ION Enterprise 6.0 SQL 2005 Express with Reporting Services SP3 (SQL Server 2005 SP3 with Reporting Services)
NOTES: The ION Enterprise 6.0 installer will upgrade an existing MSDE 2000 instance to SQL Server 2005 Express with Reporting Services. ION Enterprise 6.0 does not support SQL Server 2000. It also does not support SQL Server 2008

  • Original article#16492

    Public

    All content © 1992-2009 Schneider Electric


Legacy KB System (APS) Data: RESL188782 V3.0, Originally authored by KBAdPM on 11/02/2007, Last Edited by JaMc on 10/15/2009
Related ranges: ION Enterprise V5.5, ION Enterprise V5.0, ION Enterprise V4.5, ION Enterprise V4.0

What is the Pin out detail for the Modbus programming cable 110 XCA 20 3000?

The pin out details of the Modbus programming cable 110 XCA 20300 is as shown in the attached.

 

Are there any fuse holders in 200A

This range is now obsolete

Is there an auto switched, single GPO in the 2000 series?

Yes, we have the 2010 which is an auto switched, single GPO in the 2000 series.

For more information, please refer to the link:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=2010 



 

Is ION Enterprise 5.6 compatible with Microsoft Office XP or 2000?

Microsoft (MS) Office XP or 2000 are older versions of the MS Office suite. The Commissioning Guide for ION Enterprise recommends Excel 2003 as a minimum version and the earlier versions have not been tested by the Software department, however, there are customers who have successfully installed MS Office 2000 and ION Enterprise 5.6 together. If there are any problems using an older version of Office, the resolution is to upgrade to Office 2003.

Last Revised: November 22, 2007
Applies To: ION Enterprise 5.6
Public
All content © 1992-2007 Schneider Electric


Legacy KB System (APS) Data: RESL189470 V1.0, Originally authored by KBAdPM on 11/23/2007, Last Edited by KBAdPM on 11/23/2007
Related ranges: ION Enterprise V5.6

Does the 31288 come with handle?

31288 does not come with handle existing handle is reused on the extension kit.

Wanting a spare handle for isolator...630 to 1600....31296 ...https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=31296
and 2000 - 2500 ....31298..............................................https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=31298

 

What is the part number for the floor pedestal outlet box that can have back to back 2000 & C2000 Series switch plates and GPO's?

The part number for the floor pedestal outlet box that can have back to back 2000 & C2000 Series switch plates and GPO's is - FP125DBL

For further information, visit the link below:-
https://www.clipsal.com/Trade/search-results?q=FP125DBL

How much current is available on the USB ports of the Com'X 200?

Issue:
A user wants to use a USB device with the Com'X 200 and needs to know how much current can be supplied to their device.

Product Line:
COM'X200
EBX200

Evironment:
USB on the COM'X200

Cause:
The current available on the USB 2.0 ports has a defined limit, and is not the same on all ports.

Resolution:
There are three USB ports on the Com'X 200. In the Metering and Data Acquisition System Instruction sheet (Document Reference: 253534170), the USB ports are labeled "USB port", USB1 port", and "USB2 port".

The "USB port" is on the front face of the device, and can source 500mA (milli amp) of current.

Behind the front cover, the "USB1 port" is facing to the side and can source 100mA of current.

Also behind the front cover and facing forward, the "USB2 port" can source 500mA of current.

The images below are extracted from the instruction sheet for your convenience:





What material is 2000 series made of?

The 2000 series is made of Polycarbonate.

For further information please visit https://www.clipsal.com/Trade/search-results?q=2000%20series&section=1_SWITCHES%20AND%20SOCKET%20OUTLETS

What is part number for 4 gang C-Bus 2000 series switch?

The part number for 4 gang C-Bus 2000 series switch is 5034NL.

What is part number for metal surround to suit 2000 series?

The part number for metal surround to suit 2000 series is 2000M-GD.

What is part number for 4 gang 2000 series surround?

The part number for 4 gang 2000 series surround 2000/4.

What is the part number for a 200A 2 stud fuse carrier

Part number is PDL 772

Is the 2000 Series or C2000 IP66 Rated?

No, unfortunately 2000 series products are not IP66 Rated.
However, we do offer a very limited range in the C2000 and 2000 series that are IP66 rated.
The items are as follows:
Cat No. Description
2031V66 Single switch for vertical mounting - 2000 Series
2031H66 Single switch for horizontal mounting - 2000 Series
2032V66 Twin switch for vertical mounting - 2000 Series
2032H66 Twin switch for horizontal mounting - 2000 Series
C2031V66 Single switch for vertical mounting - C2000 Classic
C2031H66 Single switch for horizontal mounting - C2000 Classic
C2032V66 Twin switch for vertical mounting - C2000 Classic
C2032H66 Twin switch for horizontal mounting - C2000 Classic
C2031V66IC Identifi cation kit + cover for C2031V66 - C2000 Classic
C2031H66IC Identifi cation kit + cover for C2031H66 - C2000 Classic
C2032V66IC Identifi cation kit + cover for C2032V66 - C2000 Classic
C2032H66IC Identifi cation kit + cover for C2032H66 - C2000 Classic
Some of there key features are:
  • 1 or 2 gang weatherproof switch
  • 84 mm apart Mounting centres
  • Switches have been re-designed to provide mechanisms that can be re-orientated horizontally or vertically

See attached document for the catalogue on these products.

For furter information please visit https://www.clipsal.com/Trade

 

What is the Clipsal (C2000) range equivalent for PDL650VH?

There is no C2000 equivelant. The closest option in clipsal would be the blank 2000 series grid and surround - 2031VX-WE

Is the 2031vetr available in the C2000 series?

It is only available in either the standard series ( 31VETR) or 2000 series ( 2031VETR)

What are the part numbers of the 32A and 45A cooker switches that are unmarked?

Below are the part numbers of the cooker switches that are unmarked.
2031/45 Single-pole 250V, 45A - 2000 Series
C2031/45 Single-pole 250V, 45A - C2000 Series
2031D32 Double-pole 415V, 32A - 2000 Series
C2031D32 Double-pole 415V, 32A - C2000 Series
2031/45N Single-pole, includes Neon, 250V, 45A - 2000 Series
C2031/45N Single-pole, includes Neon, 250V, 45A - C2000 Series
2031D32N Double-pole, includes Neon, 415V, 32A - 2000 Series
C2031D32N Double-pole, includes Neon, 415V, 32A - C2000 Series
For further information, please visit https://updates.clipsal.com/ClipsalOnline/Files/Brochures/A0000272.pdf

What is the part number for a cover for Clipsal 2000 Flush Surround range?

2000-** colour

What year was 2000 series released?

Product was released in 1987.

With Power Suite V1.5, I understand that the PS for Pocket PC can be installed for iPAQ 3800/3900. What about the newer series of iPAQs (eg 2200 and 5...

Goals and Symptoms

With Power Suite V1.5, I understand that the PS for Pocket PC can be installed for iPAQ 3800/3900. What about the newer series of iPAQs (eg 2200 and 5500)? Does the PS support this product series? Does it also work with Pocket PC 2003? Thank you.

Causes and Fixes

Powersuite v1.5 doesn't work under PC2003, for that you need to wait the V2 of Powersuite ( forecast end 2003 ) with Ipaq22xx in qualification.


Legacy KB System (APS) Data: RESL157567 V1.0, Originally authored by on , Last Edited by on
Related ranges: Other VVD PRODUCTS

What is the part number for a mounting block for the 2030 , 1 gang architrave switch?

The part number for a mounting block for the 2030 , 1 gang architrave switch is - 70/1

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=70/1
User-added image

What is part number for C2000 series Double GPO Double pole shuttered?

The part number for C2000 series Double GPO Double pole shuttered is a C2025DS-WE.
For more information please refer to the following link:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2025DS

What is the 2000 series blank plate

 The part code 2031VX-WE

Old clipsal product 6600A needed

 Obsolete and deleted. End of life 2000

Plate for 2031

Clipsal 2000-we

What is a 2000 Series power point?

The 2000 Series power point is a 2025.
  • 10A Double Power Point
  • 240V AC
  • 2000 Series
For further information please visit: https://www.clipsal.com/Trade/Products/ProductDetail?catno=2025

User-added image

The “Generic Modbus” application does not provide status bits values in binary

Issue:
The “Generic Modbus” application does not provide status bits values in binary

Product line:
Generic Modbus Application or Similar application


Environment:
Generic Modbus Application or Similar application


Cause:
The “Generic Modbus” application does not provide status bits values in binary


Resolution:
Take the value provided by the application and convert it to binary by using a calculate like the one provided by Windows.  If using the Windows calculator, you may have to change the calculator to scientific or Programmer mode to accomplish this conversion.

Below is a couple of examples from a Galaxy VX:

Example 1:  Register 400002 (16385)

16385 in BIN 100 000 0000 0001

This example has 14 bits and to get to 16 bits two zeros were added to the left (red text)

10 0000 0000 0001 is 0010 0000 0000 0001

 

Example 2:  Register 400010 (512)

512 in BIN 10 0000 0000

This example has 10 bits so six bits needs to be added to the left (red text)

10 0000 0000 is 000 0010 0000 0000



The “Generic Modbus” application does not provide status bits values in binary

Issue:
The “Generic Modbus” application does not provide status bits values in binary


Product line:
Generic Modbus Application or Similar application


Environment:
Generic Modbus Application or Similar application


Cause:
The “Generic Modbus” application does not provide status bits values in binary


Resolution:
Take the value provided by the application and convert it to binary by using a calculate like the one provided by Windows.  If using the Windows calculator, you may have to change the calculator to scientific or Programmer mode to accomplish this conversion.
Below is a couple of examples from a Galaxy VX:
Example 1:  Register 400002 (16385)
16385 in BIN 100 000 0000 0001
This example has 14 bits and to get to 16 bits two zeros were added to the left (red text)
10 0000 0000 0001 is 0010 0000 0000 0001
 
Example 2:  Register 400010 (512)
512 in BIN 10 0000 0000
This example has 10 bits so six bits needs to be added to the left (red text)
10 0000 0000 is 000 0010 0000 0000

 

Do you have a LED floodlight biger than 100W?

Yes, we do have a 200W LED floodlight. The part number is FLH200LED.

What is the life cycle of the 30MBP?

The 30MBP has been tested to 12000 cycles.

How to identify the SQL Server Version and Edition?

This article applies to SQL 2000 and SQL 2005 only.

To check you SQL server version and edition, run the following query on the SQL instance:

SELECT SERVERPROPERTY('productversion'), SERVERPROPERTY('productlevel'), SERVERPROPERTY('edition')



The results are:
- The product version (for example, 8.00.534).
- The product level (for example, "RTM" or "SP2").
- The edition (for example, "Standard Edition"). For example, the result looks similar to: "8.00.534 RTM Standard Edition"

Use the following table to identify your version:

  • Release Sqlservr.exe
    SQL Server 2000 RTM 2000.80.194.0
    SQL Server 2000 SP1 2000.80.384.0
    SQL Server 2000 SP2 2000.80.534.0
    SQL Server 2000 SP3 2000.80.760.0
    SQL Server 2000 SP3a 2000.80.760.0
    SQL Server 2000 SP4 2000.8.00.2039
    SQL Server 2005 RTM 2005.90.1399
    SQL Server 2005 Service Pack 1 2005.90.2047
    SQL Server 2005 Service Pack 2 2005.90.3042

"RTM" means that no Service Pack has been applied.

More Information
https://support.microsoft.com/kb/321185




Last Revised: November 26, 2007
Applies To: SQL Server
Public
All content © 1992-2007 Schneider Electric

Legacy KB System (APS) Data: RESL189707 V1.0, Originally authored by KBAdPM on 11/26/2007, Last Edited by KBAdPM on 11/26/2007
Related ranges: ION Enterprise V5.0, ION Enterprise V5.5, ION Enterprise V5.6

Configuring Native USB Power Options in Windows 2000, XP, or 2003

Issue:
How to configure native USB power option.

Product Line/s:
Back-UPS
Smart-UPS

Environment:
Microsoft Windows 2000, XP or 2003

Cause:
Installation / Set-up

Solution:

Please see attached PDF.

What is the maximum operation altitude for an ATV61/71 drive without derating?

Issue:
What is the maximum operation altitude for an ATV61/71 drive without derating?

Product Line:
Altivar 61, Altivar 71, ATV61, ATV71

Environment:
All

Cause:
High altitude operation for ATV61 and ATV71 drives.

Resolution:
The drive can be installed up to 1000 Meter without derating.  1000 meters to 3000 meters derating the drives current by 1 % per additional 100 meters.  Limited to 2000 meters for the Corner Grounded distribution network.

Conversion
1000 meters = approximately  3280 feet

Do you have a 3 pole 200A panel mount main switch?

Yes we do have a 3 pole 200A panel mount main switch. The part number is T200-BK.

Some of the key features are:
  • Back wiring
  • Triple pole
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=T200



 

What is the part number for a 200A fuse carrier with back connection

Part number is 772, if busbar connection is required it's a 773

What is the part number for a 300amp fuse carrier

We don't have a 300amp fuse carrier, the highest is 200A

Does part code 31288 - INS630B TO 2500 FRONT STD ROTARY HANDLE include a handle?

No, the 31288 - INS630B TO 2500 FRONT STD ROTARY HANDLE does not come with a handle.

Spare handle is part code 31296 (indent)

Configuring relative setpoints for alarms on a Circuit Monitor 2000, 3000 or 4000

Certain alarms on the circuit monitor allow the user to configure the pickup and dropout setpoints in either absolute or relative mode. In absolute mode, the user enters the absolute values on which to alarm. In relative mode, the setpoints reflect a percentage of the running average of a particular value. The purpose of this knowledge base article is to describe the proper configuration of relative setpoints for the different models of circuit monitor.
Circuit Monitor 2000 Series (CM2000 or CM2):
On the CM2000, relative setpoints should be configured as the percentage of the offset from normal operation on which the user wants to alarm. In other words, the setpoints are configured from a reference of 0%. Most simply put, if the user wants to alarm when a value is 5% over the recent running average, he should enter a setpoint of 5%.

Circuit Monitor 3000 Series (CM3000 or CM3) & Circuit Monitor 4000 Series (CM4000 or CM4):
For the CM3000 and CM4000, relative setpoints are configured from a reference of 100%. Most simply put, if the user wants to alarm when a value is 5% over the recent running average, he should enter a setpoint of 105%.

*Note: Whenever possible, absolute alarm setpoints are recommended to ensure the most predictable and reliable alarming performance from the circuit monitor.


Legacy KB System (APS) Data: RESL201645 V1.0, Originally authored by MaTh on 03/15/2010, Last Edited by MaTh on 03/15/2010
Related ranges: CM4000 series, CM3000 series, CM2000 series

What is the Maximum number of BMXNOR0200 module which can be installed with a Modicon M580 CPU local rack.

The maximum number of BMXNOR0200 which can be installed within a local rack containing M580 CPU is 6.
It also depends on the model of M580 CPU is being used.

1. BMEP58 6040 can accomodate 6 BMXNOR0200 modules.
2. BMEP58 5040 can accomodate 4 BMXNOR0200 modules.
3. BMEP58 4040 can accomodate 4 BMXNOR0200 modules.
4. BMEP58 4020 can accomodate 4 BMXNOR0200 modules.
5. BMEP58 3040 can accomodate 3 BMXNOR0200 modules.
6. BMEP58 3020 can accomodate 3 BMXNOR0200 modules.
7. BMEP58 2040 can accomodate 2 BMXNOR0200 modules.
8. BMEP58 2020 can accomodate 2 BMXNOR0200 modules. 
9. BMEP58 1020 can accomodate 2 BMXNOR0200 modules. 

Can you get a double power point with 2 USB outlets?

Unfortunately no, however you can buy a single power point with 2 USB outlets, from the 2000 series and C2000 series.
These products are called: 2015USB2C for 2000 series and C2015USB2C for C2000 series.

For further information on the 2015USB2C please visit https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=2015USB2C
User-added image
For further information on the C2015USB2C please visit https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=C2015USB2C

User-added image
 
Show More