Grid Plates and Surrounds - 2000 Series, 3 Gang

White Electric | Grid Plates and Surrounds - 2000 Series, 3 Gang

Grid Plates and Surrounds - 2000 Series, 3 Gang

Item Number: 2000H3-WE

Datasheet

Specifications

Design

Range of product

  • Gangbusters
  • Series 2000
    • Product brand

      Clipsal

      Sustainable offer status

      Green Premium product

      Physical

      Mounting position

      horizontal

      Device mounting

      flush

      Type of installation

      indoor

      Depth

      13 mm

      Length

      348 mm

      Width

      75 mm

      REACh Regulation

      Reference contains Substances of Very High Concern above the threshold

      EU RoHS Directive

      Pro-active compliance (Product out of EU RoHS legal scope)

      Mercury free

      Yes

      RoHS exemption information

      Yes

      China RoHS Regulation

      Product out of China RoHS scope. Substance declaration for your information

      Environmental Disclosure

      ENVPEP120506EN

      Others

      Package 1 Weight

      115.5 g

      Package 1 Height

      15 mm

      Package 1 width

      90 mm

      Package 1 Length

      349 mm
      Show all specifications

      Documents & downloads

      hide show
      Filter items
      • All

      • CAD Files and Packs

      • Installation Instruction

      • Product Environmental

      Frequently Asked Questions

      hide show

      What is the mounting frame for the 4025H2

       Part code is 4000H2

      Is there a wall box for a 2025H2?

      The wall box for the 2025H2 is the 2157H2.

      Some of the key features are:
      • 2 gang
      • 84 mm (2 sets)
      • With sliding nuts for accurate alignment of accessory
      • Precision stamped from 0.9 mm strip bright electrogalvanised, for 2000H2 series

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2157H2

       

      What is the effect of altitude on ATV312?

      Issue:
      Wondering what is the effect of altitude on ATV312 drives?

      Product Line:
      All ATV312 and ATV31

      Environment:
      High altitude, more than 1000m

      Cause:
      Installing the drive in high altitude above sea level.

      Resolution:
      For all ATV312, less than 1000m, no derating.
      For single-phase supplie and corner grounded distribution networks, up to 2000m, derateing 1% per 100m.
      For three-phase supplies, up to 3000m, derating 1% per 100m.




       

      Video: Enabling Sell Mode on the Xantrex XW Hybrid Solar Inverter/Charger

      1) Enable Grid support in XW basic setup menu
      2) Set Grid Support Voltage to 64V (32V for XW4024) and enable SELL in XW Advanced - Grid Support menu (only if firmware on the XW inverter/charger is 1.07)
      3) Verify XW CHARGE CYCLE is '2Stg/NoFloat' in XW Advanced - Charger Settings - Charge Cycle (factory default setting)
      4) On MPPT set CHARGE CYCLE to '3 stage' in MPPT Advanced - Charger Settings - Charge Cycle 
      5) It is also recommended that the system has a minimum battery capacity of 200Ah. An additional 100Ah for every 1kW of solar power is preferable.

      Is the 32E400M leading edge or trailing edge?

      This dimmer pre-dates were there was a distinct difference between leading and trailing edge dimming. It was based on a similar structure to a leading edge dimmer however wasn't classed as either method. If you are considering changing your lights over to LED's it is recommended to replace the dimmer as well.
      The recommended part number is a 32ELEDM.
      • Optimised dimming range for smooth control of dimmable LED loads, no configuration required
      • Short circuit and thermal overload protection
      • Suitable for 1-way or 2-way switching applications
      • 400W
      • 22-240V AC
      • 30 Series Mechanism to suit Standard, 2000, C2000 SC2000 series switch plates
      For further information please visit https://www.clipsal.com/products/detail?CatNo=32ELEDM&tab-document-1=0

      How can I find a lost code on Sepam 2000?

      To find the lost code on a Sepam 2000 prior to 96/49:

      go to the control logic in which the code (password) is given
       
      To find the lost code of a Sepam 2000 later than or equal to 96/49, there are 2 options:

      If the code has not been modified using the Pocket PC:
      • go to the control logic in which the code (password) is given.
      If the code has been modified using the Pocket PC: 
      • re-load the control logic using LOGIPAM making a note of the code (password) used.

      Note: The standard code (password) for the control logics is 6543210.
      Show More