label - 2031VRC10-WE

SWITCH 1 GANG VERTICAL RCD 10MA

Catalogue Number: 2031VRC10
label - 2031VRC10-WE
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE 1

Specifications

hide show
Range of product
  • Lifesaver
  • Series 2000
    • Product brand
      Clipsal
      Device presentation
      basic element with full cover plate
      Switch function
      2-pole
      Actuator
      switch
      Number of poles
      2
      Device mounting
      flush
      Local signalling
      LED
      [Ue] rated operational voltage
      250 V AC
      Rated current
      20 A
      Standards
      AS/NZS 3190
      EU RoHS Directive
      Compliant
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • CAD Files and Packs

      • Installation Instruction

      • Product Environmental

      • Operating Manuals

      • Specifications

      • Certificates (MSDS)

      Frequently Asked Questions

      hide show

      Where should the twin brown wires be connected on 2031RC series?

      The 2031RC series consists of 2031RC30, 2031VRC30, 2031RC10, 2031VRC10, ML2031RC10 and ML2031VRC10.

      The twin brown wires power the Line Power Available LED. These wires must be connected into the Line Active and Neutral terminals with the incoming supply wires.
      For further information please refer to the attached installation instruction

      Is the 2031VRC10 an MCB/RCD or is it only an RCD?

      The 2031VRC10 is an RCD only
      For further information , visitl link below:-
      https://www.clipsal.com/Trade/search-results?q=2031VRC10
      User-added image
       

      What is the difference between the ML2031VRC10 and ML2031VRCD10?

      ML2031VRCD10 can be mounted vertically and horizontally whereas the ML2031VRC10 is vertical only.

      What is the difference between the ML2031VRC10 and ML2031VRCD10?

      ML2031VRCD10 can be mounted vertically and horizontally whereas the ML2031VRC10 is vertical only.

      What is the new code for ML2031VRC10

      new code is ML2031VRCD10

      What is the alternative for the PDL 691RCD10 in red

      If it is not in a hospital you could use a PDL 691RCD10 in white and order a red cover as a special.  For a hospital use a Clipsal ML2031VRC10 and Clipsal 2025RD together in a double surround.

      Is the ML2031VRC10 double pole ?

      Yes, the ML2031VRC10 is 2 pole RCD

      Some of the key features are:
      • 1 gang
      • Amber indicator marked supply power available
      • Red indicator marked line power available
      • In-built test facility
      • < 40 ms trip time
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=ML2031VRC10.

      What is the part number for a replacement for 15/15/EL30?

      There is no direct replacement for this unit. Customer would be able to use 3 items to make this up - 2015/15 , 2031RC30 & 2000H2

      For further information , visit links below:-
      https://www.clipsal.com/Trade/search-results?q=2015/15
      https://www.clipsal.com/Trade/search-results?q=2031RC30
      https://www.clipsal.com/Trade/search-results?q=2000H2
      User-added image

      User-added image
      User-added image

      Does the 2025RC10 have safety shutters?

      No, the 2025RC10 does not have safety shutters.

      Some of the key features are:
      • Earth leakage switch with IFN 30 mA
      • Frequency rating: 50 Hz
      • typical trip time: 30ms

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2025RC10

      Is there a part similar to the grid plate 2031VX that has a terminal block on the back?

      Yes, The grid plate has a terminal block on the back and is rated at 30A. The part number is 2031VXCB.

      What is the difference between the ML2031RC10 and the ML2031RCD10?

      They have the exact same operating characteristics however the ML2031RCD10 was based on the PDL design where as the ML2031RC10 is based on the Clipsal 2000 Series.
      Some of the key features are:
      • 1 gang
      • Amber indicator marked supply power available
      • Red indicator marked line power available
      • In-built test facility
      • Uses the flexible Clipsal 2000 Series system
      • < 40 ms trip time
      • Horizontal Mount
      For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=ML2031RC10


       

      What is the white cover plate for a 2031VCS

      The part code is 2000-WE surround cover plate

      How many 2025RCD10 come in a pack?

      These are supplied in a pack of 5.

      Is the Clipsal RCD 2025RC10 available in Red, Blue and Beige

      Red is available as an indent, the other two colours are not set up for sale in NZ.  Need to use ML2025RC10-DB and ML2025RC10C-BG (engraved Cleaning Purposes
      Only)

      What is the part number for a vertical Medilec RCD protected 15amp outlet?

      The part numbers for a vertical Medilec RCD protected 15amp outlet are - ML2015/15VI , ML2031VRCD10 & 2000/2

      For further information , visit links below:-
      https://www.clipsal.com/Trade/search-results?q=ML2015/15VI
      https://www.clipsal.com/Trade/search-results?q=ML2031VRCD10
      https://www.clipsal.com/Trade/search-results?q=2000/2
      User-added image


      User-added image

      What is the 2000 series blank plate

       The part code 2031VX-WE

      Do you do a 2031VH in red?

      Yes the part number is 2031VH-RD

      How do I wire my neon indicator in the ML2031VRC?

      The brown wires will be the active and neutral for the neon, these are non-polarity sensitive and go in between the line terminals.

      Is the 2031vetr available in the C2000 series?

      It is only available in either the standard series ( 31VETR) or 2000 series ( 2031VETR)

      Is the Clipsil 2000 range available in brushed aluminium?

      No, there are no metal finish surrounds available for this range.

       

      What is the minimum load for a 2031VETR?

      The minimum load for a 2031VETR is 20mA.

      For more information, please refer to the link:
      https://updates.clipsal.com/ClipsalOnline/Files/Brochures/W0001508.pdf 

      What is the Clipsal (C2000) range equivalent for PDL650VH?

      There is no C2000 equivelant. The closest option in clipsal would be the blank 2000 series grid and surround - 2031VX-WE

      What colours are the PDL 680M32 available in?

      The PDL 680M32 (switch module, 1 way, 2 terminal, 32A, 240V) is only available in white or black.
      https://www.pdl.co.nz/product-details.aspx?rcat=products&catid=0&id=825

      Can the 2031VETR and 2031VETR3 operate without a neutral?

      The 2031VETR3 will not operate without a neutral however the 2031VETR WILL operate without a neutral as it was designed purely as a 2 wire device I.e. Active & Switched Active.

      Can part number 2031VETR3 be used in conjunction with air conditioner?

      2031VETR3 can be used with air ocnditioner up to 10amps.

       

      Is mech only available for part number 2031VETR?

      No the mech comes only complete in plate.

      Can I change the output state of the 2031VETR?

      No, the output of the 2031VETR is N/O and can not be changed.

      However the 2031VETR3 has the option to choose between N/O and N/C.

      For further information please visit https://www.clipsal.com/Trade



       

      2031VETR3 - is it an intermediate switch? Can it be used in a stairwell to control a load from three floors?

      2031VETR3 is three wire switch. 
      Additional switches, 30mbp or the 30pbbp, can be installed in parallel to activate the timer from more than one location.

      Please go to the website via the following link www.clipsal.com/Trade/Products/ProductDetail and check under the Documentation Tab for more information.
       

      Is the 2031VETR3 available in a 15 amp version?

      No , The 31VETR series are available in 10a versions only
      For more information regarding this product range please visit the Clipsal web site on the link provided.
      https://www.clipsal.com/Trade/search-results?q=31vetr
      User-added image

      What is the time delay available on the 31VETF or 2031VETF?

      The 31VETF Series is adjustable to allow fans to continue to run from 3 minutes to 10 minutes (approximately) after the lighting is turned off. The delay adjustment is accessible on the
      rear of the device.

      Does 2031VETR3 have a remote input?

      Yes you can remotely switch the timer using a bell press mechanism.
      Please follow link below for more information.
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR3

      What is the part number for a replacement 3 speed fan controller for the 30 series unit - 2031VF3CSF?

      The part number for a replacement 3 speed fan controller for the 30 series unit - 2031VF3CSF is - 30CSFM

      For further information , visit link below:-
      www.clipsal.com/Trade/search-results?q=30CSFM
       

      What size is the conduit entry in the 9001BR enclosures?

      Issue:
      What size is the conduit entry in the 9001BR enclosures?

      Product Line:
      Harmony Control Stations

      Environment:
      All Products

      Cause:
      Product Features

      Resolution:
      1/2-14 NPT Pipe tap in bottom only.


      CTA-ID : 2018569

      How can 31VETR3/ 2031VETR3 push button timers be remotely switched?


      For 31VETR3/ 2031VETR3 push button timers to be remotely switched, additional switches have to be installed in parallel, allowing the timer to be activated from one or more remote locations as shown in the wiring diagram below:


      NOTE:
      • The remote switch wiring must be rated for 240V a.c.
      • The sum of cable lengths used to connect the remote switches must not exceed 100m.
      • Remote switches MUST be Normally Open momentary operation type switches.
       

      Will the 2031VETR3 handle an Air Conditioner?

      The unit has a powerful 10AX switching capability. However, regarding the Air Conditioner, it comes under a "Motor Load" which then de-rates it to 2 Amp's.
      Generally speaking, a small AC is 11 Amp's and up! Therefore it is inadequate and the use of a contactor in conjunction with the 2031VETR3 is needed.

      For further specifications on this product please visit https://updates.clipsal.com/clipsalonline/files/brochures/w0001156.pdf
       
       

      What type of switch mechanisms can be used to remotely switch 31VETR3 / 2031VETR3 push button timer?

      Momentary switch mechanisms (Bell press mechanisms) can be used to remotely switch 31VETR3 / 2031VETR3. Example of 30 series momentary switch mechanisms are 30PBBP or 30PBBPL.
      For further information, please visit 
      https://updates.clipsal.com/ClipsalOnline/Files/Brochures/W0001273.pdf
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=30PBBP
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=30PBBPL

      What is the part number of the three speed fan controller mechanism in 2031VF3CSF?

      The part number of the three speed fan controller mechanism in 2031VF3CSF is 30CSFM. The Clipsal 30CSFM Series Three Speed Fan Controller is designed to
      provide discreet, linear speed control over small motor loads, including Clipsal’s extensive range of Airflow Ceiling Sweep Fans.

      For further information please refer to the below link:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=30CSFM


       

      Is there a Saturn push button timer plate?

      No there is not, however using a 2031VETR3 with a 60PBBP to remotely switch it from a saturn plate will achieve the same result.

      Do you do a 2031VETR3 in Classic Series?

      No unfortunately we don't do a 2031VETR3 in Classic Series. However, this unit can be remotely operated. Therefore you can place the 2031VETR3 In the wall cavity and can be triggered by a C2031VH plate with a 30PBBP switch mechanism. This insures the correct look while obtaining correct functionality.


       

      What would be the part number for a timer delay switch timer delay switch.

       The part number would be 2031VTER3-WE.
      All Clipsal electronic timers feature a remote connection facility which allows any number of remote push-button switches to be connected between this terminal and the neutral, to remotely trigger the timer. Timer switches are a convenient way of saving energy and money in areas where lights are usually needed for a limited or known time, such as pantries, stairways, bathrooms and storerooms.
      The time can be set up to 254 minutes and comes in a range of colours.
      Please see following link under the documents tab for more details and installation instructions.
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR

      How does the three wire push button timer 31VETR3 or 2031VETR3 work?

      The built in push button on the 31VETR3 or 2031VETR3 has the following functions:
      • Pressing the button when the timer is passive will initiate timing and set the load, and indicator, to the active state according to the configuration switch settings.
      • Pressing the button during timing will cancel timing and set the load, and indicator, to the passive state according to the configuration switch settings.
      • To restart the timer when the load is already on, simply perform consecutive turn-on and turn-off functions.
      For further information, please refer to the below link:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=31VETR3
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR3
       

      Can the timer 2031VETR3 run a 1500W timer?

      The 2031VETR3 timer can run 1500W heater as it is rated to 10A and 1500W is = 6.52A. There fore it is well with in its rating

                                             Watts (P)                                                 1500

      Current (A) =          ----------------------                     =        ----------------------        = 6.52A
                                          Voltage  (V)                                                230

      Can i wire multiple 30PBBP momentary press mechanisms in parallel with the 2031VETR3 time delay switch?

      It is a momentary press so there isn't any restriction in how many mechanisms are wired in parallel providing your cable length doesn't exceed 100M.


      Some of the key features are:
      • 0 - 15 Hours timer range
      • Surface mounted
      • 84 mm mounting centre
      • N.O/N.C contact type
      • -10 to 50 deg C
      • Improved terminal design-Ease of wiring termination and simplified installation
      • Connection for remote push-button switch-Permits remote control of timer from any number of locations using a standard push-button switch.
      • Variable timer settings-Allows the timer to be used for maximum energy savings in a wide range of applications
      • New enclosure design-Provides more room for wiring and easier fitting into standard wall box
      • State of the art microprocessor design-Highly reliable and accurate timing
      • Near zero crossing turn on switching-Prolongs the life of the relay contacts - in excess of 100,000 operations
      • Simple set up procedures-Fast installation
      For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR3