wall box vertical 2000 series

WALL BOX VERTICAL 2000 SERIES

Catalogue Number: 2157/4
wall box vertical 2000 series
Colour:
Colour: Per UOM Std.
  • 1 PCE 1

Specifications

hide show
Range of product
Series 2000
Product brand
Clipsal
Shape
rectangular
Number of gangs
4 gangs
Cable entry number
37
Material
steel
Surface treatment
electro-galvanized
Length
279 mm
Width
98 mm
Depth
58 mm
Location of connection
rear
REACh Regulation
Free of Substances of Very High Concern above the threshold
REACh free of SVHC
Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Installation Instruction

  • Product Environmental

  • Operating Manuals

  • Specifications

  • Certificates (MSDS)

Frequently Asked Questions

hide show

What are the dimensions for wall boxes , 2157/2 and 2157/3?

Dimensions are :
2157/2 -  L136mm x W98mm x  D58mm
2157/3 -  L207mm x W98mm x  D58mm
For further information , visit links below:
https://www.clipsal.com/Trade/search-results?q=2157/2
https://www.clipsal.com/Trade/search-results?q=2157/3
User-added image
 

What is the dimensions Clipsal 2157/4

Dimensions  -  279 x 98 x 58d

What mounting accessories are available for 2025V3/30PF?

Metal Plaster mounted bracket - 2155PRM4
Metal Wall Board Mounting Clip - 2154/4
Metal Wall Box - 2157/4

Is there any bracket available for a 2000/4?

There is no stud bracket, you could use the 2154/4 mounting clip.

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2154/4

What is the wallbox to suit the 4025H2?

The part name is as follows: 2157H2

What is the flush box to suit the Clipsal 4025H2-OM ?

Use a Clipsal 2157H2

What is the flush box to suit the Clipsal 4025H2-OM ?

Use a Clipsal 2157H2

What is the wall box for a P2033/2VA-WE

 Part code 157/2

What are the dimensions of a 157/2F fire rated wallbox?

The dimensions of a 157/2F fire rated wall box is 94mm(H) X 97mm(W) X 47mm(D).
 

What are dimensions of 157/1?

Dimensions for part number 157/1 is a 94mm x 54mm x 39mm.

Are there instructions for 15724 Timer?

Told Yes

What are the part names for the mounting equipment for the Saturn 4025H2?

Wall clip - 2154H2
Wall Bracket - 2155PHRM2
Wall Box - 2157H2

What is wall box to suit Saturn Zen part no Z4025H2

The 2157H2 is used on both standard Saturn & Saturn Zen

What mounting options can be used with 4025H2 or Z4025H2 ?

Use a 2154H2 ( wall clip) , 2155PHRM2 ( plaster mount bracket ) or 2157H2 ( Wall box) recessed 8mm
for more information on this product range please visit the Clipsal web site on the link provided
https://www.clipsal.com/Trade/search-results?q=4025h2

Are there any instructions for a 15724 timer?

 Yes, there is an instruction sheet for the 15724 timer.

For further information please view the attached document.

 

Can you use two flush boxes behind a Saturn quad socket?

Yes you can it has 2x84mm mounting centers. Or you can use the 2154H2 mounting bracket or the 2157H2 Metal wall box.

L1JCN - What is the code for the flush box to suit 31/2VX-WE

157/2 wall box 2gang

Can the 157/1F be used in brick?

Yes, the157/1F replaces the F157/1 it can be used in both gyprock and masonary.

Some of the key features are:
  • 1 gang
  • Sliding nut
  • Adjustable 84 mm centres. Robust construction
  • High quality corrosion resistant finish
  • Ample knockouts
  • 1 and 2 hour fire rating - back to back
  • Acoustic rated up to STC50
  • Suitable for virtually any fire rated application
  • Sound transmission rating for virtually any application
  • For masonry walls

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=157/1F
 

What is the part number for a lid to suit the 265/4 ?

The part number is 265/4LID-GY
For more information on this product range please visit the Clipsal web site on the link provided
https://www.clipsal.com/Trade/search-results?q=265/4

Will ML2025RC10, Medilec RCD protected outlet fit into 157/1 wall box?

Yes, 157/1 can be used as a wallbox to install ML2025RC10.

For further information, please visit

157/1
https://www.clipsal.com/Trade/Products/ProductDetail?catno=157/1


ML2025RC10
https://www.clipsal.com/Trade/Products/ProductDetail?catno=ML2025RC10

What is the galvanised flush box to suit BSL range for prison application

The part code is 157/1

What is the flush box to suit the P2025/2?

Standard 2 gang flush box will suit -  part number 157/2

What is the code for a flush box to suit the 408/3?

408/3 has 84mm mounting centres so can be mounted on standard clipsal flush box like the 157/1 for example.

Do you have a disposable cover for a 157/1 PRM wall box?

Yes, we do have a wall box spacer for the 157/1PRM wall box. The part number is SL2000WBS.

What bracket is used to suit the larger Prestige range.

The bracket would be the 156/2.
This is also available in a wall box version as a157/2.
Please see below documentation for more information.
https://www.clipsal.com/Trade/Products/ProductDetail?catno=156/2

What is the part no for the lid only as a spare of a 265/4?

The part no is 265/4LID

Please see the following link for further details: https://www.clipsal.com/Trade/Products/ProductDetail?catno=265/4LID

User-added image

What wall box is required for the Metal plate range BSL25A-WE and BSL31VA-WE?

The 157/1 can be used, but ensure that the wall box is mounted 25mm from outer wall surface.

What is the part number for the lid to suit the adaptable box 265/4?

The part number for the lid to suit the 265/4 adaptable box is - 265/4LID.

Some of the key features are:

  • For adaptable box 265/4
  • Grey colour
  • IP56

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=265/4LID


 

 

Is there a junction box with minimum internal dimensions of 110mm(L) X 80mm(W) X 50mm(H) that also has a certain degree of weather protection available?

Yes the 265/4 would be suitable for the application. It is slightly larger however, it will meet the desired requirements.
Some of its key features are:
  • Surface mount
  • Dimension: 108 mm Length x 108 mm Width x 76 mm Height
  • 143.7 mm screw centres C, 89 mm screw centres D
  • Weatherproof, full cover plate
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=265/4


PowerSCADA Expert 8.2 Update 5 - Release Notes

Issue
What is new in PSE8.2 and a detailed listing of resolved problems and minor enhancements.

Product Line
PowerSCADA Expert 8.2 (PSE8.2)

Environment
Installer
 
Cause
A new PSE8.2 cumulative update release.

Resolution
PowerSCADA Expert 8.2 Update 5 - Release Notes
Release Notification (Updated 25 April 2018)

This is a detailed listing of resolved issues and minor enhancements in this release.

 


 

Prerequisite

You must have PowerSCADA 8.2 installed prior to installing this update. No previous updates are required.

Cybersecurity Announcement

Floating License Manager v2.1 addresses vulnerabilities in the Flexera FlexNet Publisher component detailed in CVE-2016-10395, CVE-2017-5571 and CVE-2016-2177. Uninstall the current version of the Floating License Manager, and then install version 2.1.
NOTE: The Floating License Manager v2.1 installer is included with this hotfix release but is not a part of the hotfix installer. Unzip "Floating License Manager v2.1.zip" and run "setup.exe".

Important Notice: There is a known issue with the Floating License Manager v2.1.0.0 installer. When installing with a logged-in Windows User name containing a space, the install will not succeed. The workaround is to install the Floating License Manager with a user that does not include a space character in their name.

Bug Fixes and Enhancements

TFS 21482 - AlarmEvents with a state of normal returned in GetAlarmEvents response for EWS

GetAlarmEvents was changed to not return alarms in the normal state.

TFS 21483 - Incorrect timestamp information provided for AlarmEvents not in the Active state

Alarm timestamps are now updated to reflect the true timestamp of occurrence for all state changes (active, drop out, acknowledge).

TFS 21484 - Unable to filter AlarmEvents by Type using EWS

Alarms are now filtered based on type. 

TFS 21485 - Unable to successfully acknowledge alarms using EWS

In some situations, EWS would not acknowledge alarms correctly.  This behavior has been fixed.

TFS 21486 - Unable to filter alarms using the PriorityTo and PriorityFrom fields

EWS did not observe the priority field correctly. This has been addressed and the minimum allowable priority has been set to 1 (to exclude non-alarm objects in the PowerSCADA alarm database).

TFS 21557 - PowerSCADA projects - including the starter project, PLS_Include, and PLS_Example - need to be upgraded to support the new DBF schemas

PowerSCADA projects have been upgraded to the latest DBF schemas.  If there are existing projects created from the starter project, set [CtEdit] Upgrade = 1 in the Citect.ini file using the Setup Editor, and then restart PowerSCADA Studio.

TFS 21564 - Alarm Proxy does not show the analog alarm states

Alarm Proxy now reports the analog alarm states (HIGH HIGH, HIGH, LOW, LOW LOW) instead of ON / OFF.

TFS 21566 - If a CSV file that does not exist is selected in the I/O Device Manager, the application throws a runtime exception

 

A message is displayed indicating that the file does not exist.

 

TFS 21569 - On large systems with 200k configured alarms, the GetAlarmDefinitions call in Alarm Proxy is slow and causes ENM to timeout

Performance issue in alarm proxy has been resolved.

TFS 21649 - When CoreServiceHost adds and removes devices, it may lose the original IDs

CoreServiceHost now keeps a device chronicle.  When the device is removed and then later added, the ID will remain the same.

TFS 21913 - If the equipment name is changed in the system, but the I/O Device name is unchanged, CoreServiceHost will not refresh the equipment name

CoreServiceHost now properly updates the equipment on name change.

TFS 21935 - Logs that are too large for the Windows Event Log do not get logged properly

Large logs are now broken down into smaller log entries.

TFS 21970 - Profile Wizard and Automation does not support IPv6

Profile Wizard and Automation now supports IPv6 for TCP/IP Board level drivers.  This requires the TCP/IP Driver version 4.0.0.0 or later.

TFS 21975 - Open and Close buttons are disabled at runtime on equipment popup when separate digital tags are used for commands

The form now enables the command buttons if the Pos_On or Pos_Off tags are defined.

TFS 21979 - Alarm Proxy cannot return alarms that transition to inactive

This setting is now configurable in the Application Configuration Utility.

TFS 22043 - Single sign-on calls from a remote thick client do not work

Single sign-on now detects remote clients.

TFS 22060 - The I/O Device Manager cannot bulk import devices with device names greater than 16 characters

The I/O Device Manager now reads the device name length from the equipment.profiles file for proper validation.

TFS 22066 - Wonderware ArchestrA Logger Security Patch

Wonderware ArchestrA Logger Patch 2017.517.2328.1 is applied.

TFS 22150 - Alarm filters do not work on some resolutions

Alarm filter AN numbers are fixed for all alarm page resolutions.

TFS 22155 - Alarm filters perform exact matching

The alarm filter screen allows the user to select the filtering mode. The default setting is read from the INI file [Alarm] FilterMode.  0 (default) = Exact Match, 1 = Starts With, 2 = Ends With, 3 = Contains.

TFS 22306 - The equipment tree used on alarm pages is slow to render over the web client

Any page using the equipment tree should set the default library and symbol on the equipment tree genie, or set 'Hide Symbol Icons' to 'TRUE' if a default icon is not available.

TFS 22401 - Alarm filter and equipment tree filter operate independently

The alarm filter and equipment tree filter operate together to filter the alarm tables.

TFS 22896 - Core service host logs two warnings during shutdown - exception thrown during disposal.

 

Cleanup methods were reworked to prevent the exception.

 

TFS 22898 - EWS cannot obtain tag updates at a 5 second rate

EWS and core services were updated to obtain data at a 5 second poll rate.

TFS 23262 - Equipment popup alarm table does not acknowledge or disable alarms

Alarms can now be acknowledged or disabled in the equipment page.

TFS 23274 - Equipment.profiles cannot be imported into the Profile Editor in cases where the original Device Types and Device Profiles were lost

The Profile Editor can import the equipment.profiles file to generate device types, device profiles, and tags.

TFS 23437 - Citect 2016 Updates

 

Citect 2016 Update (April 10, 2018) is included with this update.

Project ID management was removed from Citect 2016.  Project IDs are now located in the ProjectInfo.xml file. 

MinUnitNumber and MaxUnitNumber (previously stored in UnitNumberRange.xml) have also been migrated to ProjectInfo.xml.

 

TFS 23637 - The Alarm Summary page does not display state information

The Alarm Summary page now displays the state that caused the alarm.

TFS 23650 - 8.2 install does not enable ASP feature within IIS

The installer now enables the ASP feature under IIS. This server role feature is required to run the Citect web control client. (Previously the View-Only web client was the only option for web deployment.)

TFS 24205 - When Core Services receives a timeout from the Client, alarm processing may halt until the service is restarted

Core Services properly recovers from a ctApi deadlock condition.

Files Modified

Applications\AppServices\bin\Framework.dll
Applications\AppServices\bin\Framework.ServiceHost.exe
Applications\AppServices\bin\Modules.CoreServices.dll
Applications\AppServices\bin\PowerLogic.Cipher.dll
Applications\AppServices\bin\Modules.ProviderBase.dll
Applications\AppServices\bin\Modules.ProviderEngine.TestHarness.exe
Applications\AppServices\bin\ObjectFactoryTools.exe
Applications\AppServices\bin\ProviderGatewayProviders.dll
Applications\AppServices\bin\PowerSCADA.Common.dll
Applications\AppServices\bin\Modules.Platform.Citect.dll
Applications\EWS\bin\Framework.dll
Applications\EWS\bin\EWS.dll
Applications\EWS\Web.config
Applications\EWS\DataExchange.svc
bin\de\ProfileEngine.resources.dll
bin\de\ProfileWizard.resources.dll
bin\de\WizardLibrary.resources.dll
bin\es\ProfileEngine.resources.dll
bin\es\ProfileWizard.resources.dll
bin\es\WizardLibrary.resources.dll
bin\fr\ProfileEngine.resources.dll
bin\fr\ProfileWizard.resources.dll
bin\fr\WizardLibrary.resources.dll
bin\it\ProfileEngine.resources.dll
bin\it\ProfileWizard.resources.dll
bin\it\WizardLibrary.resources.dll
bin\ja\ProfileEngine.resources.dll
bin\ja\ProfileWizard.resources.dll
bin\ja\WizardLibrary.resources.dll
bin\ko\ProfileEngine.resources.dll
bin\ko\ProfileWizard.resources.dll
bin\ko\WizardLibrary.resources.dll
bin\ru\ProfileEngine.resources.dll
bin\ru\ProfileWizard.resources.dll
bin\ru\WizardLibrary.resources.dll
bin\zh-chs\ProfileEngine.resources.dll
bin\zh-chs\ProfileWizard.resources.dll
bin\zh-chs\WizardLibrary.resources.dll
bin\zh-cht\ProfileEngine.resources.dll
bin\zh-cht\ProfileWizard.resources.dll
bin\zh-cht\WizardLibrary.resources.dll
bin\ProfileAutomation.dll
bin\ProfileEngine.dll
bin\ProfileWizard.exe
bin\WizardLibrary.dll
bin\ProfileAutomationUtility.exe
bin\CommsMethodProperties.xml
bin\DeviceManagementUserControlLibrary.dll
Applications\Profile Editor\Tags.xml
Applications\Profile Editor\ProfileEditor.Business.dll
Applications\Profile Editor\ProfileEditor.exe
Applications\Profile Editor\ProfileEditor.UserControls.dll
Applications\Profile Editor\Resources\ProfileEditor.UserControls.resources
User\PLS_Include\*
User\PLS_Example\*
Starter\Default_Starter.ctz

Installation

Unzip "PowerSCADA Expert 8.2 Update 5.zip" and run "PowerSCADA Expert 8.2 Update 5.exe".