Surface Enclosures, Mounting box with 20 mm end entries

White Electric | Surface Enclosures, Mounting box with 20 mm end entries

Surface Enclosures, Mounting box with 20 mm end entries

Item Number: 238-WE

Datasheet

Specifications

Design

Sustainable offer status

Green Premium product

Product brand

Clipsal

Physical

Number of gangs

1 gang

Device mounting

surface

Length

115 mm

Depth

38 mm

REACh Regulation

Free of Substances of Very High Concern above the threshold

REACh free of SVHC

Yes

EU RoHS Directive

Compliant

Toxic heavy metal free

Yes

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Environmental Disclosure

ENVPEP110719EN

Material

Material

plastic

Others

Shape

rectangular

Cable entry number

2

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

125.0 g

Package 1 Height

3.9 cm

Package 1 width

7.5 cm

Package 1 Length

11.6 cm
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

Frequently Asked Questions

hide show

What does NST mean on Altivar drives?

Issue: 
NST on Altivar drives.

Product Line:
All Altivar drives

Environment:
All

Cause:
NST is not a fault but rather a status indicating the drive is in a freewheel stop condition.

Resolution:
NST is a very general status on drives.  It is not a fault condition.

See below for a number of reasons why NST is present depending on application/setup.
Causes and fixes :
 
The drive is in 2 wire control (TCC = 2C) and was powered up with an active run command.
Cycle the run command or set TCT to LEL. (IO menu, 2 wire type = level)
https://www.se.com/ww/en/faqs/FA238669/

The drive has an input assigned to Freewheel stop, NST.
The input needs to be active.
https://www.se.com/ww/en/faqs/FA170907/

The drive is in 3 wire control (TCC =3C).
LI1 must be active before the NST will clear.
https://www.se.com/us/en/faqs/FA274804/

The drive is being controlled by serial communication, and drive is not receiving the proper command signal.
The drive will display NST until the correct value has been written to the command word.
https://www.se.com/ww/en/faqs/FA314997/

A loss of a 4-20mA signal is programmed to freewheel stop.
When the input is lost, status goes to NST. Verify the 4-20 mA signal.

The drive is in terminal control, and the STOP button on the integral or remote keypad was pressed.
While in terminal control, the STOP button functions as an E-STOP.  If the keypad STOP button is pressed, the drive will go to NST (excluding the ATV212, which will display a flashing "E"). Power cycle the drive to clear the NST.
https://www.se.com/us/en/faqs/FA164112/

For the ATV61/71 VFD only: If the drive is running, and the voltage applied to the PWR input terminal drops below +19Vdc, the drive will stop and display NST.
You will need to make sure you close the +24 VDC to PWR input and cycle off and on the run command again. Make sure the factory-installed jumper between +24 and PWR is connected firmly. Or if a safety circuit is connected to these terminals, be sure the circuit is closed.  

What are the main differences between Masterpact MTZ and Masterpact NT/NW?

MaterPact MTZ follows the same footprint as of NT/NW.
However, it uses Micrologic X which is only compatible with MTZ.
MTZ is an advanced/modern ACB which is future ready as well as EcoStruxure ready. It also has the same power connections and thermal properties.
It also has class 1 energy metering.
Existing AS/NZS 61439-1 switchboard certificates with NT/NW are valid for MTZ.
MTZ doesn’t require a test kit it uses EPC - EcoStruxure Power Commission software for testing, commissioning and reports.
https://www.se.com/au/en/work/products/product-launch/ecostruxure-power-commission/

For all the differences between the two ranges please refer to MTZ Substitution guide - https://www.se.com/ww/en/download/document/LVPED516027EN/

For all the information on the Masterpact MTZ range, please refer to MTZ Catalogue: https://www.se.com/ww/en/download/document/LVPED216026EN_WEB/


Sample_3.gif

What are the differences between Acti9 PowerTag Link C (A9XELC10) and Acti9 PowerTag Link (A9XMWD20) / Link HD (A9XMWD100)?

image.png
Acti9 PowerTag Link C (A9XELC10)
This is a cloud connected communication module which can ONLY be used with Facility Expert Small Business (FESB) app.


There is no webpage access to connect to Acti9 PowerTag Link C. All the commissioning steps are performed through the eSetup for Electricians app which is connected to PowerTag Link C using Bluetooth connectivity.
Please see more details in the PowerTagLink C Instruction Sheet and Facility Expert Small Business (FESB) brochure.

Please note that Facility Expert Small Business (FESB) app is not designed to use in residential applications and not supported for solar applications to see energy export values.***

Also, there is no option to log the kWh consumption data in the app or export them as reports.

Please download the Facility Expert SB app from Google Play or App Store and go to ‘Demo Mode’ to explore more.

*** If you are interested in solution for residential applications with solar, please check out our Wiser Energy Management solution.




image.png
Acti9 PowerTag Link (A9XMWD20) / Link HD (A9XMWD100)
These are used to monitor small/medium business electrical equipment via your supervision system through PowerTags Energy sensors.


These can be accessed via a webpage or EcoStruxure™ Power Commission software to configure and set notifications. These gateways itself do not log data.

Alternatively, PowerTag Link/Link HD can be connected to a COM’X 210/510 to connect to a cloud based platform, Facility Expert where you are able to see your energy data as well as your asset status. This platform has a yearly subscription fees and the fee depends on the inclusions in your license.

Please refer the below FAQ video and the PowerTag Link Gateway User Guide.
Set a Panel with PowerTag Energy Using PowerTag Link Webpages
https://www.youtube.com/watch?v=olAqAX8H3U8
 
 

Video: How to import an EDS file into SoMachine?

Issue:
How to import an EDS file into SoMachine?

Product Line:
Somachine, EDS, M238, M258, M251

 

What's the difference between a regular Home member, an Administrator and the Homeowner?

The Homeowner has access to all functions. Administrator has access to all functions except the ability to transfer the homeowner rights, delete the home and granting administrator rights to other members. A common member only has access to operate devices, receive notifications (alarm, moment/automation trigger, device added/removed and invite) from a home, configure device settings and schedules.

I’m building a new home and have been thinking about installing smart home controls, but my budget is already stretched, and I really don’t think I can afford it…

Having a smart home doesn’t need to be expensive or extensive. With a range of scalable options, Clipsal makes smart living accessible to everyone.

Simply choose the smart home solution that works for you, your lifestyle and budget – whether that be two switches and a few smart sockets, or the whole nine yards. 

Clipsal offers in-home Bluetooth control and full out-of-home control via C-Bus, so you can opt for as little – or as much – connectedness as you like.

Clipsal also offers some clever electrical accessories; start building your smart home with Infrascan Motion Sensors to save energy by never accidentally leaving the lights on. You may also enjoy using timers, time-clocks and dimmers.

On the higher end of smart home solutions, C-Bus gives you the ability to control lighting, irrigation, air conditioning, multiroom audio, windows and blinds, home theatre, home security, keyless entry and more.

See what smart home solutions are available