box junct round 2way 20mm

BOX JUNCT ROUND 2WAY 20MM

Catalogue Number: 240/20/2
box junct round 2way 20mm
Colour: Electric Orange
Colour: Per UOM Std.
  • Electric Orange 1 PCE 1
  • Grey 1 PCE 1

Specifications

hide show
Range of product
Series 240
Product brand
Clipsal
Material
PVC (polyvinyl chloride)
Shape
round
REACh Regulation
Free of Substances of Very High Concern above the threshold
REACh free of SVHC
Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile
N/A

Frequently Asked Questions

hide show

What is the part number for a plug to suit the 240/25?

The part number for a plug to suit the 240/25/3 is a 220/25.
 

What is the part number of a Junction box with 25mm entry but entries in U shape?

Unfortunately we dont make U entry junction box any more, closest will be 240/25/2A and similar.

What are the dimensions for the wall box for the E01/20/2?

The dimensions for the wall box for the E01/20/2 are - H198mm x W150mm x D70mm
For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=E01/20/2
User-added image

What is the part number for a 20mm 2 way conduit J-Box?

The part number for a 20mm 2 way conduit J-Box is - 240/20/2

For further information , visit link below;-
https://www.clipsal.com/Trade/search-results?q=240/20/2
User-added image

What is the wall box to suit the B4/30/2 ?

 The part number for the wall box is 164/2

Is there a deep version of the 253/25/2 junction box?

Yes, there is a deep version of the 253/25/2 junction box. The part number is 253/25/2D.

Some of the key features are:
  • Deep oblong, draw in box
  • 2 way through entry
  • Dimension: 150 mm Length x 30 mm Width x 42 mm Depth
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=253/25/2



 

What is the part number for din mounted transformer 240/24V AC 60VA?

The part number for din mounted transformer 240/24V AC 60VA is ABL6TS06B + ABL6AM02
+ Related image

  ABL6TS06B                                                                             ABL6AM02
voltage transformer - 230..400 V - 1 x 24 V - 63 VA                     plate for mounting on symmetrical DIN rail - for voltage transformer

For more information see:

https://www.schneider-electric.com/en/product-range-selector/1537-phaseo-abt7--abl6/?p_url=http%3A%2F%2Fwww.ops-ecat.schneider-electric.com%2Fecatalogue%2Fbrowse.do%3Fel_typ%3Dproduct%26cat_id%3DBU_AUT_1537_L3%26prd_id%3DABL6TS06B%26scp_id%3DZ000                                                      
                                                                                                                                         

What is the form number to get a 9012 type G preset from the factory?

Issue:
Ordering

Product Line:
Industrial Pressure Switches

Environment:
9012G

Cause:
Preset range and differential settings

Resolution:
Add for Y1 to the catalog number and  include the pressure settings  on the markings section in Quote to Cash in order to process the order. ( ie. 9012GBW2Y1 ( 400 FALL- 435 RISE) )

CTA-ID : 2042032

 

 

What is the analog inputs range in voltage mode for the IMC card ?

In the IMC hardware guide, 04/2012 (s1a10252.06.pdf) and in IMC Instruction Sheet (bbv60941_02.pdf), a schematic shows that analog inputs AI51 and AI52 range in voltage mode is 0-10 V.
These inputs only support 0-5 V.
Correction will be applied in the next release of these documents.

Where can I get a copy of the ATV61 Programming Manual?

Issue:
Customer needs to download the Altivar 61 Programming Manual.
 
Product Line:
ATV61
Altivar 61
 
Environment:
All models, all part numbers
 
Cause:
Manuals are not shipped with the product. 
They are available online for download.

Resolution:
The ATV61 programming manual is available online in our Tech library.  Please follow the following link to be taken to location of the file:
https://www.schneider-electric.us/en/download/document/1760649/

 

How do I hardwire 10kva and 20kva transformers in a 208/120 or 240/120 environment

Issue:
Implementing a hardwire stepdown transformer in a 208v or 240v environment


Product Line:

Smart-UPS / Symmetra

Environment:

APTF10KT01, APTF10KW01, and APTF20KW01, All Serial Numbers

Cause:

Unbalanced UPS outputs require a stepdown transformer to power 120v loads


Resolution:

This document refers to installing  the APTF10KT01, APTF10KW01, and APTF20KW01 transformers in a North American 120/240 or 120/208 environment. For installations in other regions please consult the users manual.

The wiring block outputs are as follows:


For domestic use, make sure that the Terminal Block Jumper is installed between the Ground Terminal and Terminal 8 on the output wiring block, as illustrated on page 8 of the user manual. Please also make sure that the input voltage switch is in the correct position.

The step-down transformer provides 240/120 output as 2 120v hots, a neutral, and a ground. It provides 208v output as a 120v hot, an 88v hot, and a ground. The 120v hot (terminal  7) and the 88v hot (terminal 9) are 180 degrees out of phase. You will measure 208v from terminals 7 to 9. The step-down transformer is not able to provide 2 120v hots that are 120 degrees out of phase as you would see with utility power.



 Note: If your installation requires both 208v and 120v output power you will need 2 separate subpanels: a 240v/120v panel and a dedicated 208v subpanel.

Is there an alternative for 1239/20/1, Round, 20mm, 1 Way Entry, Light Duty Junction Box?

 Yes, however the alternatives may vary in style, material or number of entries.

The closest alternative in galvanised cast iron is a Junction Box, Round- 20mm I.D, 1 Way Entry, Heavy Duty. The Part number is 1239H20/1.
The closest alternative in PVC is a Junction and Adaptable Boxes PVC- 20mm Entries, 1 Way. The partn number is 240/20/1.

For further information please visit https://www.clipsal.com/Trade/searchround/jbox20MMENTRY1



             1239/20/1                          1239H20/1                           240/20/1                           



 

Which operators can be mounted in a XACA pendant station?

Issue:
Which operators can be mounted in a XACA pendant station?

Product Line:
Harmony Control Stations

Environment:
All Products

Resolution:
All ZA2 non-illuminated operators can be mounted in the cover or the bottom except for 60mm mushroom buttons. Also 3 position selector switches can not be used in the bottom. There are no contact blocks that will work with the 3 position selector switch in the bottom. Pilot lights and the XACA booted operators can be mounted in the cover only.
 

What is the part number for a Contactor with Low consumption?

The part number for a low consumption contactor is LC1D09.
General Product information:
Range of product TeSys D
Product or component type Contactor
Device short name LC1D
Contactor application Motor control Resistive load
Utilisation category AC-1, AC-3
Poles description 3P
Power pole contact composition 3 NO
[Ue] rated operational voltage <= 300 V DC for power circuit
<= 690 V AC 25...400 Hz for power circuit
[Ie] rated operational current 9 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit
25 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
Motor power kW 5.5 kW at 660...690 V AC 50/60 Hz
5.5 kW at 500 V AC 50/60 Hz
4 kW at 415...440 V AC 50/60 Hz
4 kW at 380...400 V AC 50/60 Hz
2.2 kW at 220...230 V AC 50/60 Hz
Motor power HP (UL / CSA) 7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors
5 hp at 460/480 V AC 50/60 Hz for 3 phases motors
2 hp at 230/240 V AC 50/60 Hz for 3 phases motors
2 hp at 200/208 V AC 50/60 Hz for 3 phases motors
1 hp at 230/240 V AC 50/60 Hz for 1 phase motors
0.5 hp at 115 V AC 50/60 Hz for 1 phase motors
Control circuit type AC 50/60 Hz
Control circuit voltage 415 V AC 50/60 Hz
Auxiliary contact composition 1 NO + 1 NC
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Overvoltage category III
[Ith] conventional free air thermal current 10 A at <= 60 °C for signalling circuit
25 A at <= 60 °C for power circuit



For more information please visit https://www.schneider-electric.com.au/en/productcontaLC1D