tee conduit pvc insp 20mm

TEE CONDUIT PVC INSPECTION 20MM. 246/20,EO REPLACES GET246/20,EO.

Catalogue Number: 246/20
tee conduit pvc insp 20mm
Colour: Electric Orange
Colour: Per UOM Std.
  • Electric Orange 1 PCE 1
  • Grey 1 PCE 1

Specifications

hide show
Product brand
Clipsal
Range of product
Series 246
Material
PVC (polyvinyl chloride)
Diameter
inner: 20 mm
Length
  • 55 mm
  • 92 mm
    • REACh Regulation
      Free of Substances of Very High Concern above the threshold
      REACh free of SVHC
      Yes
      EU RoHS Directive
      Pro-active compliance (Product out of EU RoHS legal scope)
      Toxic heavy metal free
      Yes
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
       Pro-active China RoHS declaration (out of China RoHS legal scope)

      Frequently Asked Questions

      hide show

      Is there a 246/50 in orange?

      Yes we do but it is manfactured to order.

      What would be a longer screw to suit Clipsals round j-boxes (Junction Boxes)?

      The part number would be 248/20 which is a combination screw head 20MM 3/16 BSW.

      Is part number 242/50 suitable for underground?

      Yes. Part number 242/50 is suitable for underground.

      Can I order the 220/20 in white?

      Yes, you can order the 220/20 in white but it needs to be done as a special.
      For more information, please refer to the link:https://www.clipsal.com/Trade/Products/ProductDetail?catno=220/20

      Do you have a cap/ flange to for 20mm conduit?

      Yes the part number is 221/20

      Are the Clipsal Conduit Clips available in Electric Orange?

      No, they are only available in grey.

      This applies to the 280/16 (16mm), 280/20 (20mm), 280/25 (25mm), 280/32 (32mm), 280/40 (40mm) and 280/50 (50mm).

      Do you have a 32mm inspection Tee conduit fitting with out the inspection hole?

      No, unfortunately we only do the 246/32, 32mm, Inspection Tee with the inspection hole.

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=246/32

      What is a side Auxiliary for MCB 24626

       You can select from a range of Auxiliary on Page C20 of the 2013 Schneider A4 book

      What would be the part number for an Earth Clip, 16/20 mm.

      203M.
      Pressed Metal Conduit Fittings, Earth Clips, Water pipe adjustable earth clip 15 - 20mm or 1/2 - 3/4 inch.
      Please see following link under the documentation tab for full catalogue.
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=203M

      Comment fonctionne les compteurs d'energie de l'ATS48.

      Goals and Symptoms

      Comment fonctionne les compteurs d'énergie de l'ATS48.

      Causes and Fixes

      Il existe 2 compteurs:

      - le compteur en kW ( puissance active ) de 0 à 999 kW;
      - le compteur en kW/h qui nécessite le fonctionnement du démarreur pendant au moins une heure ( pour la première ). Son échelle est de 0 à 65535, soit 7,4 années ( 7j/7 et 24h/24 ).

      What are the part numbers of slip type expansion couplings?

      Slip Type Expansion Couplings are available from 16mm through to 50mm.The part numbers of slip type expansion coupling are as follows:
      16mm = 251/16
      20mm = 251/20 *
      25mm = 251/25 *
      32mm = 251/32
      40mm = 251/40 *
      * = only available in Grey
      Where long conduit runs are likely to be exposed to wide variations in temperature, it is recommended that expansion couplings be used at each join. It is not recommended that Slip Type Expansion Couplings be used where the conduit run is exposed to the weather. Standard colour is Grey (GY).
      Dimension details are attached.
       

      How do I hardwire 10kva and 20kva transformers in a 208/120 or 240/120 environment

      Issue:
      Implementing a hardwire stepdown transformer in a 208v or 240v environment


      Product Line:

      Smart-UPS / Symmetra

      Environment:

      APTF10KT01, APTF10KW01, and APTF20KW01, All Serial Numbers

      Cause:

      Unbalanced UPS outputs require a stepdown transformer to power 120v loads


      Resolution:

      This document refers to installing  the APTF10KT01, APTF10KW01, and APTF20KW01 transformers in a North American 120/240 or 120/208 environment. For installations in other regions please consult the users manual.

      The wiring block outputs are as follows:


      For domestic use, make sure that the Terminal Block Jumper is installed between the Ground Terminal and Terminal 8 on the output wiring block, as illustrated on page 8 of the user manual. Please also make sure that the input voltage switch is in the correct position.

      The step-down transformer provides 240/120 output as 2 120v hots, a neutral, and a ground. It provides 208v output as a 120v hot, an 88v hot, and a ground. The 120v hot (terminal  7) and the 88v hot (terminal 9) are 180 degrees out of phase. You will measure 208v from terminals 7 to 9. The step-down transformer is not able to provide 2 120v hots that are 120 degrees out of phase as you would see with utility power.



       Note: If your installation requires both 208v and 120v output power you will need 2 separate subpanels: a 240v/120v panel and a dedicated 208v subpanel.

      What are the pinouts for current inputs on the AMI0810 when using the FTW308 cable with pigtail leads ?

       

       

       
        : Here are the pin assignments for current inputs I0 - I7 when using the FTW308 cable and the BMXAMI0810 .
       
            
          Current input 0  +                   pins 1/3 blue/white & white/blue are jumped together
          Current input 0  common        pin 2 white/orange
       
          Current input 1  +                   pins 4/6  green/ white & white/green are jumped together
          Current input 1  common        pin 5 orange/white
       
          Current input 2  +                   pins 7/9 white/brown  & brown/white are jumped together
          Current input 2  common        pin 8   white/gray 
       
          Current input 3  +                   pins 10/12 blue/red & red/blue are jumped together
          Current input 3  common        pin 11 gray/white
       
          Current input 4  +                   pins 15 /17 red/ orange & orange/ red are jumped together
          Current input 4  common        pin 16 red/green
       
          Current input 5  +                   pins 18/20 brown/red & red/brown are jumped together
          Current input 5  common        pin 19 green/red  
       
         Current input 6  +                 pins 21/23 red/gray & gray/ red are jumped together
         Current input 6  common        pin 22 black/blue
       
         Current input 7  +                   pins 24/26 black/orange & orange/ black are jumped together
         Current input 7  common        pin 25 blue/black 


      R-6-30-17

      Legacy KB System (APS) Data: RESL211859 V1.0, Originally authored by DaSo on 06/21/2013, Last Edited by DaSo on 06/21/2013
      Related ranges: Modicon M340

      There is an application with Altivar 38 with pump switching card where the auxiliary pump is driven by an Altistart 48.There is also Modbus connection...

      Goals and Symptoms

      There is an application with Altivar 38 with pump switching card where the auxiliary pump is driven by an Altistart 48.There is also Modbus connection where the master is a Twido PLC and the slaves are the ATV38 and the ATS 48. The problem is that en error ERR 7 (erreur LS) is appeared at the ATV38 display.What kind of error is that and what can we do about it?

      Facts and Changes

      ATV38 with Modbus connection

      Causes and Fixes

      Product trips transiently to "Err3" or "Err7" fault. Both faults type are generated by the display module.
      This one communicates with the microprocessor of control card .
      When incorrect messages occur during the communication and after some repetition of exchanges , the display module shows to "ErrX".
      This is a very difficult fault to reproduce because depending of environment ( lenght of wire between display module and control board , motor running, disrupted site ) and the combination between display module and control board.

      Origin of problem :

      Insufficient immunity of communication facing the various disturbances.
      The communication frames managing is made by integrated components called "drivers". One is located on control board, the same is inside display module. This fault is the result of wrong interpretation of display module of logic level between two communication frames.
      This technical conceived problem is appeared from August 2000.

      Corrective action:

      This failure has been resolved by a modification of two values of resistors inside the display module.
      The revision levels become:
      · A20, B20 for the ATV58 display modules.
      · A02 for the ATV58Fdisplay modules.

      This evolution is applied from the week 47/2000 on all manufactured PRODUCTS and all VW3A58101 spare parts.


      Information for internal use:

      We have noticed that anyway neither control board nor display module have never been directly to the fault origin . Fault "Err X" is always due to the association of two items.

      On no account this failure cannot to disrupted the motor running but she can to disturb only the programming of product.

      If during the programming, a customer encounters to " Err3 " or " Err7 " with a product manufactured from the week 31/00 to 46/00 , it is advised to exchange only the VW3A58101 display module.

      This problem can also appear if the baudrate of internal communication was modified ( subD 9 pins ) and there is a difference between the keypad and internal modbus.

      A solution is to reset the inverter with the 50/60 Hz switch to return the baudrate in factory setting, don't forget to accord the Twido PLC.


      Legacy KB System (APS) Data: RESL156317 V3.0, Originally authored by on , Last Edited by on
      Related ranges: Altivar 38