bend conduit pvc solid 40mm

BEND CONDUIT PVC SOLID 40MM

Catalogue Number: 247/40
bend conduit pvc solid 40mm
Colour: Electric Orange
Colour: Per UOM Std.
  • Electric Orange 1 PCE 1
  • Grey 1 PCE 1

Specifications

hide show
Product brand
Clipsal
Range of product
Series 247
Material
PVC (polyvinyl chloride)
Diameter
40 mm
Operating angle
90 °
Length
155 mm
Inner radius
100 mm
Standards
AS/NZS 2053
REACh Regulation
Free of Substances of Very High Concern above the threshold
REACh free of SVHC
Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)

Frequently Asked Questions

hide show

Is part number 242/50 suitable for underground?

Yes. Part number 242/50 is suitable for underground.

Is there a 246/50 in orange?

Yes we do but it is manfactured to order.

What would be a longer screw to suit Clipsals round j-boxes (Junction Boxes)?

The part number would be 248/20 which is a combination screw head 20MM 3/16 BSW.

What is the current rating for an 847 mains entry box?

 80A

Are the Clipsal Conduit Clips available in Electric Orange?

No, they are only available in grey.

This applies to the 280/16 (16mm), 280/20 (20mm), 280/25 (25mm), 280/32 (32mm), 280/40 (40mm) and 280/50 (50mm).

What is the replacement for 16066 Timer?

The replacement for 16066 Timer is A9E16066.

A9E16066
iRTB relay-delays de-energizing a load upon closing-1C/O - Uc 24-240 VAC/24VDC

For more information see:
https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9E16066

What is the part number for the bitsa box?

The part number for the bitsa box is 357TB.
Some of the key features are:
  • Tool boxes
  • 12 compartment transparent box with assorted screws, screws and quantities included
  • Includes: 357WF30 (100), 357/20 (150), 357WH12 (350), 357P30 (200), 357P20 (300), 357WH25 (100), 357PH50 (50), 357/63 (50), 357WHP32 (100), 357PH45 (100), 357/35 (100), 357/40 (100)
For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=357TB


 

Typical 3-line drawings for Sepam Series 20, 40 and 80 current and voltage input connections

Goals and Symptoms

Typical 3-line drawings of Sepam 20/40 Feeder, Sepam 20/40 Main and Sepam 80 Main/Feeder.

Causes and Fixes

See attachment
Sepam.zip



AEDL3
Legacy KB System (APS) Data: RESL203669 V1.0, Originally authored by MiZe on 10/09/2010, Last Edited by MiZe on 10/09/2010
Related ranges: Sepam series 80, Sepam series 40, Sepam series 20

What are the part numbers of slip type expansion couplings?

Slip Type Expansion Couplings are available from 16mm through to 50mm.The part numbers of slip type expansion coupling are as follows:
16mm = 251/16
20mm = 251/20 *
25mm = 251/25 *
32mm = 251/32
40mm = 251/40 *
* = only available in Grey
Where long conduit runs are likely to be exposed to wide variations in temperature, it is recommended that expansion couplings be used at each join. It is not recommended that Slip Type Expansion Couplings be used where the conduit run is exposed to the weather. Standard colour is Grey (GY).
Dimension details are attached.
 

What is the operating principle of a detector for XSAV type rotation control?

Advantage and preferred uses

  • XSAVxx inductive sensors for rotation control have the special feature of combining data acquisition functions and processing by a pulse comparator in a single unit, thus creating an integrated rotation control device.
  • These devices provide a good solution for monitoring slip, belt break, coupling break, overloads, etc. in the following applications: conveyor belts, bucket elevators, lifting screws, grinders, crushers, pumps, centrifugal drying machines, mixing machines, etc.


Principle

The output signal of this type of sensor is processed by a pulse comparator integrated in the device.

The frequency of the pulses Fc emitted by the moving element to be monitored is compared with the frequency Fr preset on the device.

The output switching circuit of the sensor is at closed state when Fc > Fr and open state when Fc < Fr.

XSA-V sensors are particularly suitable for underspeed detection: when the speed of the moving element to be monitored Fc falls below a preset threshold Fr following deceleration, this detection leads to opening of the device's output circuit.

 

Other characteristics

  • Two ratings: 0.1 Hz-2.5 Hz and 2 Hz-50 Hz
  • Cylindrical inductive sensor, diameter 30
  • Range 10 mm

Special features:

  • Detection and comparison of pulses are integrated in the device
  • The frequency is preset in the device using a 15-turn potentiometer
  • Caution: The adjustment of the threshold is not linear according to the number of turns
  • For both ratings there is a 3-wire model with 12-48 VDC power supply and a 2-wire model with 24-240 VAC or 24-210 VDC power supply
  • Rotation monitoring becomes effective 9 s after the sensor MST
  • Connection via 2 m cable

Can the PowerLogic Energy Meter be used to monitor multiple loads?

Issue
A user would like to totalize multiple loads with an Energy meter.

Product Line
Powerlogic Energy Meter

Environment
Energy Meter Installation

Cause
The installation guide for the Energy meter does not contain instructions on wiring the meter to monitor multiple loads.

Resolution
*Warning: Installation and maintenance of this device should only be performed by qualified, competent personnel that have appropriate training and experience with high voltage and current devices. Failure to follow the instructions / warnings in the Meter Installation Guide can result in permanent damage to the meter, severe injury or death. 

The Energy meter is calibrated with the set of CTs that are included with the meter, however the Energy Meter can be installed with up to three sets of parallel CTs to monitor multiple loads. When wiring multiple current transformers in parallel to the Energy Meter, all voltages corresponding to the individual loads must be the same voltage values and must be from the same source. The voltage applied to the inputs of the Energy Meter will be used in the power calculations. Monitoring different voltage values and monitoring the same voltage values from different sources will both cause the power calculations to be inaccurate.

For example, if load A has a system voltage type of 120/208 VAC, and load B has a system voltage type of 277/480 VAC, an Energy Meter cannot be used to measure both loads in a parallel configuration. Likewise, if Load A and Load B both have a system voltage type of 120/208 VAC, but are supplied their respective voltage from different transformers, an Energy Meter cannot be used to measure both loads in a parallel configuration.

Note: When multiple sets of CTs are connected in parallel to the Energy Meter, the accuracy drops from less than 1% to between 1%-3%.


Please follow the guidelines in the attached addendum for selecting and installing the parallel CTs on an Energy meter.

Are EasyPact MVS circuit breakers for sale in the USA or Canada?

Issue:
Where can I buy a EasyPact MVS breaker?

Product Line:
EasyPact MVS circuit breakers

Resolution:
There are no plans for a general release of the EasyPact MVS circuit breaker line in the US.