socket swt twin remov e/sw

SWITCHED SOCKET TWIN REMOVABLE EXTRA SWITCH

Catalogue Number: 25XA
socket swt twin remov e/sw
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE 1

Specifications

hide show
Product brand
Clipsal
Range of product
Standard Series
Control type
ON/OFF button
Number of gangs
2 gangs
Pin number
3
Number of power socket outlets
2
Actuator
  • rocker
  • switch
    • Mounting position
      horizontal
      Fixing mode
      by screws
      Local signalling
      without light indicator
      Material
      PC (polycarbonate)
      Surface finish
      glossy
      [Ue] rated operational voltage
      250 V AC
      [In] rated current
      10 A
      Depth
      16 mm
      Length
      115 mm
      Width
      73 mm
      Fixing center
      84 mm
      Standards
    • AS/NZS 3100
    • AS/NZS 3112
    • AS/NZS 3133
    • AS/NZS 3000:approval number S/1
      • REACh Regulation
        Reference contains Substances of Very High Concern above the threshold
        EU RoHS Directive
        Compliant
        Mercury free
        Yes
        RoHS exemption information
        Yes
        China RoHS Regulation
        Product out of China RoHS scope. Substance declaration for your information
        Circularity Profile
        N/A

        Documents & downloads

        hide show
        Filter items
        • All

        • CAD Files and Packs

        • Installation Instruction

        • Product Environmental

        • Specifications

        • Certificates (MSDS)

        Frequently Asked Questions

        hide show

        Will 30USBCM fit on 25XA, twin outlet with extra switch?

        Unfortunately not. 30USBCM will not fit on 25XA. We have 2025USBC, C2025USBC, 4025USBC and Z4025USBC twin outlets with 30USBCM assembled on the plate.
        For further information, please visit https://updates.clipsal.com/ClipsalOnline/Files/Brochures/A0000294.pdf

        What components do I need for a 100A, 25kA MCCB

         You will need LV429003 + LV429030

        What is the part number for a 3 pole, 63A, 25kA circuit breaker?

        Unfortunately the closest we have to this is a 3 pole, 63A, 25kA circuit breaker. The part number is A9N18467.

         

        What is the part number for a 160A 25kA thermal-magnetic trip?

        The part number for a 160A 25kA thermal-magnetic trip is a - LV430310.
         

        What is the part number for the 3 Pole 250 Amps 25kA MCCB?

        The part number for the 3 Pole 250 Amps 25kA MCCB is "LV431110"

        https://www.schneider-electric.com.au/en/search/LV431110

        Will 30USBCM fit into 25XD socket outlet

        Yes the 30USBCM will fit into 25XD.

        For more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=25XD
         

        What is the kA rating of the MB boards?

        The kA rating of the MB boards is 25kA

         
        Chassis Cold formed,Continious type - 250A with a short circuit withstanding rating - 25kA for 0.1s

        For more information please visit https://www.clipsal.com/Trade

        What are the ratings for the 250A DC disconnect in the XW PDP?

        XW 250A DC Disconnect Information 



        @ 80Vdc -> Ics= 10000A / Icu 25000A
        @ 160Vdc -> Ics=  5000A / Icu 10000A
        In : 250A
        Vimp 4KV
        Trip Current: 313A
        Max V: 160V
        AIC: 10000A

        What is the part number of the 60 pole distribution board with MSC chassis, 250A main switch and IP56 rating?

        The part number of the 60 pole distribution board with MSC chassis, 250A main switch and rated to IP56 is MD260E32.
         

        Do you have a double pole outlet with USB mechanism?

        No. However, you can assemble one yourself using a 25XD and a 30USBCM.

         

        What is the part number for a 48 pole switchboard with 250A main switch?

        The part number for a 48 pole switchboard with 250A main switch is - MB248D32

        For further information, visit the link below:-
        https://www.schneider-electric.com.au/en/search/MB248D32
         

        What is the part number for a 250A manual changeover switch?

        The part number for a 250A manual changeover switch is - 31146

        For further information, visit the link below:-
        https://www.schneider-electric.com.au/en/search/31146
        User-added image

        What is the part code for a 96way pan assembly (Chassis) ?

        C325963TFW. Fits C60 MCB's x 96 Poles. Total Rating = 250A

        Does the MB248DM2 come with a main switch?

        Yes it comes with a 250A main switch.

        What is the part number for a 250A 48 pole chassis for iC60 C/B for the MB switchboards?

        The part number for a 250A 48 pole chassis for iC60 C/B for the MB switchboards is - C325483

        For further information, visit the link below:-
        https://www.schneider-electric.com.au/en/search/C325483
         

        What is the part number for a 3 phase 250A 24 pole busbar for the iC60 C/B's?

        The part number for a 3 phase 250A 24 pole busbar for the iC60 C/B's is - C325243

        For further information, visit the link below:-
        https://www.schneider-electric.com.au/en/search/C325243
        User-added image

        What is the replacement for a 4T24 Transformer?

        The replacement part number is a A9A15219.

        Some of the key features are:
        Minimum Operating Frequency 50Hz
          Minimum Temperature -20°C
          Number of Outputs 1
          Primary Voltage Rating 230V ac
          Secondary Voltage Rating 12 V ac, 24 V ac
          CAD Drawing 3D CAD Model
          Depth 60mm
          Dimensions 89 x 90 x 60mm
          Length 89mm
          Maximum Operating Frequency 60Hz
          Maximum Temperature +50°C
          Mounting Type DIN Rail
          Power Rating 25VA
          Width 90mm
        For further information please visit https://www.schneider-electric.com/ww/en/download/document/S1B8489901?showAsIframe=true

        Schneider Electric 25VA Safety Transformer, 230V ac Primary 1 x, 12 V ac, 24 V ac Secondary

        - Does the 30USBCM fit into 2025XA and C2025XA

        Yes it will fit into 2025XA / C2025XA, with the following mounting hardware only: 154, 154RM, 154/1, 155NAR, 155VNAR, 155PRM, 156/2, 157, 164, 449A. Will not fit SC2025XA / 25XA. ( Also please note that it will need to be placed into plate in vertical configuration)
        For more information on the 30USBCM please visit the Clipsal web site or click  link provided .https://www.clipsal.com/Trade/search-results?q=30usbcm

        What is the part number for a 25A 3 phase D curve breaker?

        The part name is A9F55325

        What is a 2pole 25A 56 Series isolator for a dock

        Part number is PDL 56SW332

        What is the DC22A rating for the PDL 56SW432KG

        25A @ 115V

        Is there a 40A version SPN N Vigi RCBO

         No - 25A is the largest

        What is the part code for a slim RCBO 25A

         The part code is 19586

        What is the part number for 4 pole ,C Curve, 10KA, 25A breaker?

        The part number for 4 pole , C curve, 10KA, 25A breaker is A9F54425

        A9F54425
        Acti9 iC60H 4P 25A C Miniature Circuit breaker
        For more information see:
        https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9F54425
         

        What are the characteristics of a 31CAP capacitor?

        The characteristics of a 31CAP capacitor are:
        Values Description
        Amp 0.025A (Ampere)  =  25mA (Milliampere).
        Watts 6W
        Voltage 240V
        Microfarad 0.33μF
        Maximum amount stacked in parallel 3

        For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=31CAP

        What is the pitch of the feed terminals on the Isobar chassis?

        The pitch is 20.5mm so if you want to fit a switch or circuit breaker to feed it directly you will also need to purchase an adaptor.
        The A9TNA250CK will give the correct pitch to fit a 250A NSX or INS feeder.

        On a LC1D25 contactor , are the aux contacts rated at 25A

        The aux contacts on all our contactors are rated at 10A Ith

        Is there a 32A version of an SPN N Vigi

         No - the highest current rating is 25A

        What is the complete part number for a 25A 11Kw 3P Contactor with 24VDC coil?

        LC1D25BD is the correct part number

        What would be the replacement part for the 4BB5/26.

         21501 for a 12 module and a 21503 for the 24 module. these are a Schneider part which is equivalent to the 4bb5/26
        Clipsal’s range of busbars are available in 63A - 250A versions and have been specifically designed to make installations quicker and easier.
        Please see following link for further information and complete range.
        https://www.clipsal.com/Trade/Products/ProductDetail?catno=4BB5/26

        Whats the part number for a Din rail mount 25A change over switch?

        The part number for a Din rail mount 25A change over switch is a 4PS25CO

        • Maximum 4 - Isolators - DIN rail mount
        • Night, off, day switching of luminaries where daylight supplements internal lighting
        • Incoming and outgoing terminals are screw down type and accommodate copper conductors up to 16 sq mm
        • Auto, off, manual switching of machines
        • Auxiliary, off, mains switching of small stand-by generators
        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=4PS25CO

        what is the KA rating 4rcbm232/30.

        For this 4RCBM series  range the KA rating is above 25a is limited to 6KA and below 25amps is 10ka.

        what is new code for Merlin Gerin 15960 CT Contactor ?

        new code = A9C20736  iCT Contactor 25A 2NC AC7a rated 
         

        What are the codes for the Fault Arc Detection Devices?

        6A - A9FDB606
        10A - A9FDB610
        16A - A9FDB616
        20A - A9FDB620
        25A - A9FDB625

        What is the size of the inter conductor for the N-series recloser cables (38kV)?

        This size will vary depending upon the rating of the conductors:


        • 1. 250A 80mm2
          2. 340A 120mm2
          3. 400A 180mm2
          4. 630A 240mm2
          5. 800A 400mm2

          These are shown in more detail in the attached guide.

          Olex cables.pdfOlex cables.pdf


        Legacy KB System (APS) Data: RESL212274 V1.0, Originally authored by DaFr on 08/09/2013, Last Edited by DaFr on 08/09/2013
        Related ranges: Others protection relays

        Type Test Certificate for Evolis 17.5kV 25kA 1250A

        We do not provide our test reports but instead provide a declaration of conformity in accordance with MVS policy.

        You will find attached the official note from MVS manager's which explains the different steps.

        It is only allowed if some technical discussion is started with the customer, involving skilled individuals, and a non-disclosure agreement is signed;

        For a declaration of conformity, we mention all the tests performed in accordance with IEC standards.

        We can also provide only the third first pages of each test reports.

        If a customer is adamant about needing the reports the documents will only be provided if they sign a Non Disclosure Agreement (NDA) as mentioned in the note.

        So you will find attached the declaration of conformity for Evolis fixed version 17.5 kV - 1250 A -  25 kA
         

        Can I replace a broken toggle on an NS / NSX circuit-breaker or switch.?

        No, the toggle on the breaker frame cannot be replaced as the toggle is integral to the breaker frame.

        The breaker frame needs to be replaced.

        However, the toggle extension (4 to 5 cm long piece screwed to the toggle) can be replaced, but only if the toggle thread is not damaged.
         
        If the thread is damaged the breaker frame needs to be replaced.

        For the NSX up to  250A - Part number is LV432553
        For the NSX 400A to 630A - Part number is LV429313
         

        What is the replacement for GC2504M5 Contactor?

        Video: How do I set a PowerPact or Masterpact circuit breaker with a Micrologic trip unit to a different specified amperage?

        Issue:
        What Long Time settings will adjust PowerPact P or R or Masterpact circuit breakers with Micrologic trip units to a different Amp rating?

        Product Line:
        PowerPact P, PowerPact R, Masterpact NW, Masterpact NT

        Resolution:
        The attached table gives you the ampere rating of a circuit breaker with the indicated sensor plug and Long Time (rating plug) setting.
        Note that many amp settings can be attained with more than one rating plug and sensor combination.

        Sensor plugs can be changed to a lower amperage in some cases; they cannot be increased from the original size, but they can be reduced as much as 50%.
        It is not possible to put a 100A or 250A sensor in a 400A or larger breaker.  400A and larger breakers cannot accept 100A or 250A sensors.
        See circuit breaker section of the digest for a chart showing possible sensor plugs for breakers 3200A and under.
        Sensor Plug Replacement Guide attached includes references for amperages above 3200A.

         

        What is the part number for 7gn cam switch series handle

        This will need to be raised as special - "GCR_7 series handle R014" this will suit 7 series up to 25A but not 7gf10 ( these have no spare handles available or we would need to sacrifice a switch for the handle ) 32a and above have different handle again.

        What is the part number for Contactor, 25A, 2NC?

        The part number for Contactor, 25A, 2NC is A9C20736

        A9C20736
        iCT 25A 2NC 230...240V 50Hz contactor

        For more information see:
        https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9C20736


         

        What is the replacement for a C32L-MA Multi9, Circuit breaker, 40kA, 25A?

        The closest replacement for a C32L-MA Multi9, Circuit breaker, 40kA, 25A magnetic only is a 25A, 50kA, a magnetic only unit with the dimensions of 81mm(W) X 103mm(H) X 81mm(D).
        The part number for this unit is 18884.
         
        This can be found on page 2.1.14 of the 2016 Schneider Product Guide.

        What is the alternate to part number 4EL25/2/30, 25A , 30mA, 2 module RCD?

        4RC225/30 is an alternate for 4EL25/2/30, 25A , 30mA, 2 module RCD.

        Key Features

        • Unique new white finish for a fresh modern look
        • Base module = 18 mm wide, compact standardised and consistent module dimensions
        • Lift-up terminals. Safer ‘no hot spot’ terminations and all cable strands are locked in
        • Cable automatically guided to the correct position: terminals with guard
        • Fast closure
        • The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed on the downstream circuit in complete safety
        • Same housing as AC type MCBs. Uniformity in space requirements and installation
        • Superior, safe and reliable DC breaking per pole
        • Used with marine, telecommunications, solar power, emergency power, battery power
        • Excellent breaking capability for its compact size
        • Standard type
        • 75 mm modular spacing
        • Surge current protected to 250 A at 8/20 uS
        • Operating temperature: -5 to 40 deg C
        • Degree of pollution is 2
        • Rated Impulse withstand voltage is 6 kV

        https://www.clipsal.com/Trade/Products/ProductDetail?catno=4RC225/30

        What is the part number for residential 40A combo RCD & CB?

        The part number for residential 40A combo RCD & CB is a 4RCBM240/30.
        Some of the key features are:
        • Seperate RCD trip flag for easy fault finding
        • new insulated openings for easy busbar installation
        • No need to cut the busbar providing safe and quick fit off
        • Same base module as the 10ka mcb, uniformity in space requirements and installation
        • Same housing and installation features as the mcbs. Safe, easy and fast installation
        • Top and bottom line and load compatible for ease of installation
        • Labelled terminals. Safe, easy and fast installation
        • Top and bottom clip allowing dismounting with comb busbar in place
        • Busbar compatible through an insulated slot
        • Surge current protected to 250a 8/20μs/li>
        • Operating temperature: -5 to 40 deg C
        • Standard type
        • 1-phase
        • 4 kV Rated impulse withstand voltage
        For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=4RCBM240/30






         

        What is the part number for a 16A RCD combo?

        The part number for a 16A, 30mA, 16kA RCD/ MCB is a 4RCBM216/30.
        Some of the key features are:
        • Seperate RCD trip flag for easy fault finding
        • new insulated openings for easy busbar installation
        • No need to cut the busbar providing safe and quick fit off
        • Same base module as the 10ka mcb, uniformity in space requirements and installation
        • Same housing and installation features as the mcbs. Safe, easy and fast installation
        • Top and bottom line and load compatible for ease of installation
        • Labelled terminals. Safe, easy and fast installation
        • Top and bottom clip allowing dismounting with comb busbar in place
        • Busbar compatible through an insulated slot
        • Surge current protected to 250a 8/20μs/li>
        • Operating temperature: -5 to 40 deg C
        • Standard type
        • 1-phase
        • 4 kV Rated impulse withstand voltage
        For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=4RCBM216/30

        Is the 4CNT2 rated at 25A?

         
        Yes the 4CNT2 is rated at 25A at AC1.

        Some of the key features are:
        • DIN rail mount
        • 1/2 pole
        • 1 module
        • 25 A at AC1
        • Frequency rating: 50 Hz
        • 220-250 V AC Coil
        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=4CNT2

        What is the replacement/ alternative for the 4EL25/4/30 25A RCD?

        The alternative part is 4RC425/30.

        Key Features

        • Unique new white finish for a fresh modern look
        • Base module = 18 mm wide, compact standardised and consistent module dimensions
        • Lift-up terminals. Safer ‘no hot spot’ terminations and all cable strands are locked in
        • Cable automatically guided to the correct position: terminals with guard
        • Fast closure
        • The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed on the downstream circuit in complete safety
        • Same housing as AC type MCBs. Uniformity in space requirements and installation
        • Superior, safe and reliable DC breaking per pole
        • Used with marine, telecommunications, solar power, emergency power, battery power
        • Excellent breaking capability for its compact size
        • Standard type
        • 75 mm modular spacing
        • Surge current protected to 250 A at 8/20 uS
        • Operating temperature: -5 to 40 deg C
        • Degree of pollution is 2
        • Rated Impulse withstand voltage is 6 kV

        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=4RC225/30

        Can the SCP be installed on the same location where the XW inverters have the display?

        SCP Installation Guide 

        The SCP can be installed either in the wall or it can be installed as a replacement for the XW inverter display. This can be done by the following steps.


        1.) You will have to power down the inverter completely. We have to turn the AC power coming into the unit first, then the DC power coming into the unit. The AC power usually would be a dual pole 60A breaker that is located on the PDP's (Power Distribution Panel) top left corner. The DC disconnect will be the large 250A breaker on the bottom right corner. 

        2.) Once the inverter has being turned off for no less than 5 minutes, the next step would be to uncover the inverter. This should only be performed by a qualified person. The following screws would have to be removed.



        3.) Once the is done, remove the Display connection to the Main Board and also remove the cat5 cable that connects the Display to the Main Board. This Cat5 cable will be used to connect the SCP to the main board. 

        4.) On the Main Board locate the SCP Port. 



        5.) This is what the system should look like when all is done. 



         

        Can the LH4N125RT7 be used with a motor that has a continuous current rating of 25 amps? If so, why does the catalog say the starter has a current ra...

        Goals and Symptoms

        Can the LH4N125RT7 be used with a motor that has a continuous current rating of 25 amps? If so, why does the catalog say the starter has a current rating of 22 amps? If not, why is the number 25 in the catalog number? Can you send a copy of VVD Info 93?

        Facts and Changes

        LH4N*25**7 22 or 25 amps?

        Causes and Fixes

        In fact, 25A is the thermal current ( Ith ) and 22A is the nominal current.


        Legacy KB System (APS) Data: RESL157640 V1.0, Originally authored by on , Last Edited by on
        Related ranges: LH7, LH4

        ProtectNet surge performance ratings

        Issue:

        ProtectNet surge performance ratings

        Product Line:

        ProtectNet - P10B2, P10BT, PTR, PNet1, PNet1GB, PNet4, PTel2, PTel1-4, PS9-DTE, and PS9-DCE, PSP25, PDigiTel, PS25-DTE, and PS25-DCE

        Environment:

        N/A

        Cause / Resolution:
         
        ProtectNet Model Mode Standoff voltage Breakover voltage Let-through voltage Peak surge current
        P10B2 Line-line
        Line-ground
        6 Vdc
        500 Vrms
        8 Vdc
        700 Vrms
        < 50 Vpk
        < 400 Vpk
        6,900 A
        250 A
        P10BT Line-line
        Line-ground
        6 Vdc
        1,500 Vrms
        8 Vdc
        1,800 Vrms
        < 50 Vpk
        < 1,700 Vpk
        6,900 A
        250 A
        PTR Line-line
        Line-ground
        6 Vdc
        500 Vrms
        8 Vdc
        700 Vrms
        < 50 Vpk
        < 400 Vpk
        6,900 A
        250 A
        PNet1 Line-line
        Line-ground
        6 Vdc
        1,500 Vrms
        8 Vdc
        1,800 Vrms
        < 50 Vpk
        < 1,700 Vpk
        6,900 A
        250 A
        PNet1GB Line-line
        Line-ground
        6 Vdc
        1,500 Vrms
        60 Vdc
        1,800 Vrms
        < 50 Vpk
        < 4,000 Vpk
        6,500 A
        250 A
        PNet4 Line-line
        Line-ground
        6 Vdc
        1,500 Vrms
        8 Vdc
        1,800 Vrms
        < 50 Vpk
        < 1,700 Vpk
        6,900 A
        250 A
        PTel2 metallic
        longitudinal
        220 Vdc
        200 Vdc
        260 Vdc
        260 Vdc
        < 325 Vpk
        < 325 Vpk
        150 A
        150 A
        PTel1-4 metallic
        longitudinal
        220 Vdc
        200 Vdc
        260 Vdc
        260 Vdc
        < 325 Vpk
        < 325 Vpk
        150 A
        150 A
        PS9-DTE, and PS9-DCE Line-line
        Line-ground
        28 Vdc
        28 Vdc
        36 Vdc
        36 Vdc
        < 60 Vpk
        < 60 Vpk
        200 A
        200 A
        PS25-DTE, and PS25-DCE Line-line
        Line-ground
        28 Vdc
        28 Vdc
        36 Vdc
        36 Vdc
        < 60 Vpk
        < 60 Vpk
        200 A
        200 A
        PSP25 Line-line
        Line-ground
        15 Vdc
        15 Vdc
        16 Vdc
        16 Vdc
        < 90 Vpk
        < 90 Vpk
        200 A
        200 A
        PDigiTel Metallic
        Longitudinal
        65 Vdc
        65 Vdc
        80 Vdc
        80 Vdc
        <60Vpk
        <60Vpk
        250A (8/20uS)
        250A (8/20uS)

         
        Show More