Switch Mechanisms, 30 Series, Neon Indicator Mechanisms, 250V

Amber | Switch Mechanisms, 30 Series, Neon Indicator Mechanisms, 250V

Switch Mechanisms, 30 Series, Neon Indicator Mechanisms, 250V

Item Number: 30N-AM

Datasheet

Specifications

Design

Sustainable offer status

Green Premium product

Range of product

  • Standard
  • Sundry Series 30

Product brand

Clipsal

Product or component type

indicator module

Physical

REACh Regulation

Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental Disclosure

ENVPEP120506EN

Material

Material

PVC (polyvinyl chloride)

Others

Shape

square

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

9.421 g

Package 1 Height

2.36 cm

Package 1 width

2.36 cm

Package 1 Length

2.8 cm

Unit Type of Package 2

BB1

Number of Units in Package 2

10

Package 2 Weight

0.112 kg

Package 2 Height

3.9 cm

Package 2 width

5.5 cm

Package 2 Length

11.5 cm

Unit Type of Package 3

CAR

Number of Units in Package 3

100

Package 3 Weight

1.2 kg

Package 3 Height

13 cm

Package 3 width

15 cm

Package 3 Length

19 cm
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

Frequently Asked Questions

hide show

What is the maximum output current of the ATV61HD30N4?

Issue:
Maximum continuous output current rating of the ATV61HD30N4.

Product Line:
ATV61

Environment:
ATV61HD30N4 only

Cause:
Customer unable to find information in current literature.

Resolution:
The maximum continuous output current rating of the ATV61HD30N4 is 66 amps.


 

What is the part number of the Main Control board for ATV71HD22N4?

Issue:
ATV71HD22N4:  Need to replace the Main Control board ?

Product Line:
ATV71

Environment:
ATV71HO75N4, ATV71HU15N4, ATV71HU22N4, ATV71HU30N4, ATV71HU40N4, ATV71HU55N4, ATV71HU75N4, ATV71HD11N4, ATV71HD15N4, ATV71HD18N4, ATV71HD22N4, ATV71HD30N4, ATV71HD37N4, ATV71HD45N4, ATV71HD55N4, ATV71HD75N4

Cause:
Need the Main Control board part number.

Resolution:
The Main Control board part number for these drive is VX4A71100Y

Will a 30NPA fit into a BSL25XA?

Yes it will fit.

30NPA

image.png

BSL25XA

image.png

Please go to the following links below and check under the Documentation Tab for more information.

Australia
https://www.clipsal.com/products/detail?CatNo=30NPA&itemno=30NPA-AM&backto=/search?q=30NPA&tab-document-1=0
https://www.clipsal.com/products/detail?CatNo=BSL25XA&itemno=BSL25XA-WE&backto=/search?q=BSL25XA&tab-document-1=0

New Zealand 
https://www.pdl.co.nz/products/detail?CatNo=30NPA&itemno=30NPA-AM&backto=/search?q=30NPA
https://www.pdl.co.nz/products/detail?CatNo=BSL25XA&itemno=BSL25XA-WE&backto=/search?q=BSL25XA&tab-document-1=0

What Is the voltage rating Clipsal 30N24?

The 30N24 is suitable for AC and DC loads

image.png

Please go to the website via the following links below and check under the Documentation Tab for more information.

Australia - https://www.clipsal.com/products/detail?CatNo=30N24&itemno=30N24-RD&tab-document-1=0
New Zealand - https://www.pdl.co.nz/products/detail?CatNo=30N24&itemno=30N24-AM

What are the Rated short-circuit making capacity (Icm) and Rated short-time withstand current (Icw) values of Compact NSX Switch-disconnectors (NSX xxx NA)?

Rated short-circuit making capacity (Icm) and Rated short-time withstand current (Icw) values for Compact NSX Switch-disconnectors can be found in Compact NSX Catalogue.

Icw and Icm values are defined by IEC60947 standard as following:
STA1.png
STA2.png

Icw is the value of RMS current that can flow through the disconnector for a given time without causing damage to the device.

Icm is the peak value of short circuit current that the disconnector can close to, if closing on a fault without being damaged.


Please see the following characteristic from the NSX Catalogue:
Icw NSX NA.png

For example, Icw value of NSX400 NA is 5000A/1s, that means NSX400NA can withstand 5kA/1s.
Please note that NSX switch disconnectors can’t withstand any other higher values which are not mentioned under Icw for 1 second.

The greater Icm value (330 kA) is related to the case when the disconnector is combined with upstream current limiting circuit breakers while the lower value is for switch-disconnector alone.

It is mandatory to use a circuit breaker upstream of them for protection against overloads and short circuits.

However, the Compact NSX NA switch-disconnectors are self-protected (i.e. they have a certain magnetic tripping threshold.), as noted on the catalog page. NSX NA is self-protected as soon as the switch is closed.

This function is ensured by a magnetic protection inside the switch.
The THRESHOLD self-protection by their high-set magnetic release are:
    - 10kA for the NSX100NA till NSX250NA
    - 15kA for the NSX400NA till NSX630NA

It is only an integrated partial protection to avoid contact repulsion and it could not be used for network protection. 
We have no characteristic graphs for the self-protection by high-set magnetic release, because it is not a performance value for customer application.

 

What is the part number for the thermal sensor on a ATV61 or 71HD30N4?

Issue:   
ATV61 or ATV71HD30N4 thermal sensor part number
 
Product Line:   
ATV61 ATV71
 
Environment:  
ATV61HD30N4 ATV71HD30N4
 
Cause:  
Replacement thermal sensor
 
Resolution:   
 The ATV61 / 71HD30N3 thermal sensor is a VZ3G1101
Show More