Foot Switches, Foot Switch 250V 10A - double pole

White Electric | Foot Switches, Foot Switch 250V 10A - double pole

Foot Switches, Foot Switch 250V 10A - double pole

Item Number: 360-WE

Datasheet

Specifications

Design

Product brand

Clipsal

Sustainable offer status

Green Premium product

Physical

Width

55 mm

Depth

29 mm

Length

93 mm

REACh Regulation

Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental Disclosure

ENVPEP120506EN

Others

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

75.0 g

Package 1 Height

4.0 cm

Package 1 width

8.0 cm

Package 1 Length

10.0 cm

Unit Type of Package 2

BB1

Number of Units in Package 2

5

Package 2 Weight

0.426 kg

Package 2 Height

8.4 cm

Package 2 width

10.4 cm

Package 2 Length

19.0 cm

Unit Type of Package 3

CAR

Number of Units in Package 3

50

Package 3 Weight

4.4 kg

Package 3 Height

23.7 cm

Package 3 width

20.3 cm

Package 3 Length

30.0 cm
Show all specifications

Frequently Asked Questions

hide show

How do I set up PID for sleep wakeup on an ATV21 or ATV212 drive?

Issue:
Sleep Wake Up function

Product Line:
ATV212, ATV21

Environment:
All model and serial numbers

Cause:
None

Resolution:
For PID setup see FAQ FA230136.

PID SLEEP WAKEUP can be activated by setting F256 [Time limit low spd]
Setting this function to 0 disables this function.
The range of this function is between 0 and 600 seconds.  0 deactivate this function. 

If parameter F256 is activated and if the drive operates continuously at [Low limit frequency] (LL) for a time period equal to the setting of F256, the drive will ramp the motor to a stop. While the motor is stopped, “LStP” will flash on the drive
embedded display terminal.

When the speed reference to the drive exceeds the low speed level LL+F391, the drive will accelerate the motor to the new speed
reference.

ATV212 or S-flex drive is running full speed with PID enabled drive does not appear to be responding to the PID feedback.

Issue:
ATV212 or S-flex drive is PID does not appear to be responding to the PID feedback.

Product Line:
Altivar ATV212 S-flex

Environment:
All

Cause:
Drive is running full speed and is not responding to the PID feedback

Resolution:
Troubleshooting Tips:  Check the PID feedback signal 1st to see if the drive is getting good feedback.
Check the programming F360 make sure its set to the PID feedbacks input.  VIA-1 or VIB-= 2
 

What are the catalog numbers and available voltages for shunt trip and shunt close accessories for the Masterpact NW?

Product Line:
Circuit Breakers

Resolution:
Shunt Trip, Second Shunt Trip, and Shunt Close
Voltage 50/60 HzT-, W-, & Y-Frame
Fixed
T-Frame
Drawout
W- & Y-Frame
Drawout
12 dcS47359S33809S48490
24–30 ac/dcS47360S33810S48491
48–60 ac/dcS47361S33811S48492
100–130 ac/dcS47362S33812S48493
200–240 ac/dcS47363S33813S48494
277 acS47364S33814S48495
380–480 acS47365S33815S48496

See instruction bulletin, 48049-237-03

For VA consumption

What is the operating voltage tolerance, catalog numbers, and clearing times for the Masterpact NT and NW shunt trip and shunt close coils?

Issue:  
What is the operating voltage tolerance, catalog numbers, and clearing times for the Masterpact NT and NW shunt trip and shunt close coils?

Product Line:
Masterpact NT NW

Resolution:
Shunt trip: operating threshold is 0.7x to 1.1x Vn (nominal voltage)
Shunt close: operating threshold is 0.85x to 1.1x Vn
Catalog numbers are the same for MX and MN (shunt trip and shunt close) devices; function is determined by placement in the breaker.
 
Voltage (V) at 50/60 HzT-, W-, & Y-Frame FixedT-Frame DrawoutW- & Y-Frame Drawout
12 DCS47359S33809S48490
24-30 AC/DCS47360S33810S48491
48-60 AC/DCS47361S33811S48492
100-130 AC/DCS47362S33812S48493
200-240 AC/DCS47363S33813S48494
277 ACS47364S33814S48495
380-480 ACS47365S33815S48496

MX operating time at Vn:  50 ms ±10 (NW and NT)
XF operating time at Vn:  
70 ms ±10 (NW ≤ 4000 A)
80 ms ±10 (NW > 4000 A)
55 ms (NT)

NOTE:  Shunt trip (MX) and shunt close (XF) circuits must be energized for a minimum of 200 ms. In other words, don't use an impulse signal. Use a signal of at least 200 ms.

Why is there a QR code on the MAX9 devices?

Scanning QR codes with a mobile device helps to easily access all the product specifications, Instruction Sheet, product picture, 360° views, features & benefits, certificates and compliance, brochure and related products.

QR code

What is the max duty cycle for the ATS01 soft starters?

Issue:
ATS01 duty cycle. 
 
Product Line:
Altistart 01
ATS01
 
Environment:
Frequent start/stop cycles
 
Cause:
Overheating
 
Resolution:

There are several different versions of ATS01.  Each has it's own characteristics.
See below:

ATS01N1...FT
1 second start time, 100 maximum number of starts per hour
5 second start time, 20 maximum number of starts per hour

ATS01N2206 to N222, LU, QN, RT
1 second start time, 100 maximum number of starts per hour
5 second start time, 20 maximum number of starts per hour
10 second start time, 10 maximum number of starts per hour

ATS01N232, LU, QN, RT
1 second start time, 50 maximum number of starts per hour
5 second start time, 10 maximum number of starts per hour
10 second start time, 5 maximum number of starts per hour

ATS01N2... LY, Q  THIS VERSION IS NO LONGER AVAILABLE  see the ATS22 product family instead
1 second start time, 360 maximum number of starts per hour
12 second start time, 30 maximum number of starts per hour
 

Show More