Surface Switches, 250V 10A - 2 way, 4 terminal

White Electric | Surface Switches, 250V 10A - 2 way, 4 terminal

Surface Switches, 250V 10A - 2 way, 4 terminal

Item Number: 363-WE

Datasheet

Specifications

Design

Product brand

Clipsal

Sustainable offer status

Green Premium product

Physical

Device presentation

basic element

Switch function

2-way

Control type

toggle

Device mounting

surface

Fixing mode

by screws

Local signalling

without

[Ue] rated operational voltage

250 V AC

Rated current

10 A

Marking

without marking

REACh Regulation

Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental Disclosure

ENVPEP120506EN

Others

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

42 g

Package 1 Height

33 mm

Package 1 width

51 mm

Package 1 Length

52 mm

Unit Type of Package 2

BB1

Number of Units in Package 2

5

Package 2 Weight

0.236 kg

Package 2 Height

80 mm

Package 2 width

60 mm

Package 2 Length

122 mm

Unit Type of Package 3

CAR

Number of Units in Package 3

100

Package 3 Weight

4900 g

Package 3 Height

237 mm

Package 3 width

203 mm

Package 3 Length

300 mm
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • Certificates (MSDS)

Frequently Asked Questions

hide show

What are the catalog numbers and available voltages for shunt trip and shunt close accessories for the Masterpact NW?

Product Line:
Circuit Breakers:

Environment:
Applies to Masterpact breakers NW drawout and fixed type.

Resolution:
Shunt Trip, Second Shunt Trip, and Shunt Close
Voltage 50/60 HzT-, W-, & Y-Frame
Fixed
T-Frame
Drawout
W- & Y-Frame
Drawout
12 dcS47359S33809S48490
24–30 ac/dcS47360S33810S48491
48–60 ac/dcS47361S33811S48492
100–130 ac/dcS47362S33812S48493
200–240 ac/dcS47363S33813S48494
277 acS47364S33814S48495
380–480 acS47365S33815S48496

See instruction bulletin, 48049-237-03

What are the repair parts for the HU363SS, series F6? (may be shown as F06)

Issue:
Repair parts

Product Line:
Heavy Duty Safety Switch

Environment:
Repair parts

Cause:
Maintenance

Resolution:
The repair parts for the HU363SS, series F6 (F06) are as follows. No other parts are available.

Line Base Assembly - 4056775250 (arc suppressor not included)
-Line Base mounting screw - 4020515101 (3 required)
-Arc Suppressor Assembly - 4056635550
-Arc Suppressor mounting screw - 4020514501 (1 required)
-Lug assembly - 4025101851 (per lug)
-Lug Mounting Screw - 4020514202 (per lug)
-Mechanism Assembly - 4056646950 (NOTE: Handle Coupling, Cover Interlock Defeat Coupling, and Lockplate Gaskets may also need replacing)
-Handle Coupling - 4056699850
-Cover Interlock Defeat Coupling - 4056699750
-Handle Assembly - 4056894150 (also recommend replacing Lockplate Gaskets)
-Lockplate - 4056894201 (also recommend replacing Lockplate Gaskets)
-Lockplate Gasket - 4050322802 (2 required)
-Lockplate mounting screw - 2194900001 (2 required)
-Ground Lug - 4025101851 - (2 total required)
-Ground Lug Mounting Screw - 4020514801



 

What is the field installable padlock attachment for the Masterpact NW W/Y frame breaker, or NT?

Issue:
What is the field installable padlock attachment for the Masterpact NW W/Y frame breaker, or NT?

Product Line:
Masterpact

Environment:
Products sold in North America

Cause:
Need to padlock open an existing Masterpact NW or NT

Resolution:
S48539 for Masterpact NW,  W and Y frame. S47514 for the Masterpact NT

Padlock attachment S48539

See instruction bulletin, 48049-197-02


See instruction bulletin, 48049-233-01

Video: How do you set up PID control on the ATV21 and ATV212 drives?

Issue:
PID control setup on ATV21 and ATV212 drives?

Product Line:
Altivar ATV21 and ATV212, S-Flex enclosed.

Environment:
All

Cause:
Setting up PID control on the ATV21 and ATV212 drives.

Resolution:

  1. Press the mode button until you see AUF
  2. Arrow down to F------ and press enter
  3. Find F360 and press enter choose your PID feedback assignment and to enable your PID function
  • 1 for VIA
  • 2 for VIB
        4. Set FNOD as your PID set point
  • Set to 3 if you want to use the up and down arrows as your set point.
  • Set to 1 for VIA or 2 for VIB if you want your analog input to be your set point.

Please note: it is not a good idea to set up to set your PID feedback F360 to 1 VIA and your set point  FNOD to 1 VIA. 

Basic setup for a 4-20mA signal input for PID feedback would be:
F201=20%  (4mA)
F202=0
F203=100%  (20mA)
F204= 60hz
F360= 1 (enable PID and feedback is VIA 4 to 20mA)
FNOD= 3  (up and down arrows are your set point.

Optional settings:
F362=PID proportional gain
F363= PID integral gain
F380 = 1 for Reverse acting (0 = disabled)


Ref manual 30072-451-63

What is the operating voltage tolerance, catalog numbers, and clearing times for the Masterpact NT and NW shunt trip and shunt close coils?

Issue:  
What is the operating voltage tolerance, catalog numbers, and clearing times for the Masterpact NT and NW shunt trip and shunt close coils?

Product Line:
Masterpact NT NW

Resolution:
Shunt trip:  operating threshold is 0.7x to 1.1x Vn (nominal voltage)
Shunt close:  operating threshold is 0.85x to 1.1x Vn
Catalog numbers are the same for MX and MN (shunt trip and shunt close) devices; function is determined by placement in the breaker.
 
Voltage (V) at 50/60 HzT-, W-, & Y-Frame FixedT-Frame DrawoutW- & Y-Frame Drawout
12 DCS47359S33809S48490
24-30 AC/DCS47360S33810S48491
48-60 AC/DCS47361S33811S48492
100-130 AC/DCS47362S33812S48493
200-240 AC/DCS47363S33813S48494
277 ACS47364S33814S48495
380-480 ACS47365S33815S48496

MX operating time at Vn:  50 ms ±10 (NW and NT)
XF operating time at Vn:  
70 ms ±10 (NW ≤ 4000 A)
80 ms ±10 (NW > 4000 A)
55 ms (NT)

NOTE:  Shunt trip (MX) and shunt close (XF) circuits must be energized for a minimum of 200 ms. In other words, don't use an impulse signal. Use a signal of at least 200ms.

Acti 9 iC60 3 Phase 30mA Type A RCBO available in Australia ?

Acti 9 3phase RCBOs available in Australia, are made by combining the breaker and add-on RCD module (Vigi block).

For example: 3 pole 10A 30mA RCBO is a 3 pole 10A breaker + 30mA Add-on Vigi block.
A9F44310 (3P 10A C curve iC60 breaker, 6kA) + A9V02763 (63A 30mA earth leakage add-on block 3P+N with neutral wire)

3P 10A 30mA RCBO for balanced load will be,
A9F44310 (3P 10A C curve iC60 breaker, 6kA) + A9V51363 (63A 30mA earth leakage add-on block 3P without neutral)

Vigi.png

The datasheets are in available in the link below.
A9V02763https://www.se.com/au/en/product/A9V02763/vigi-ic60---earth-leakage-add-on-block---3p-%2B-n---63a---30ma---a-type/
A9V51363 – https://www.se.com/au/en/product/A9V51363/vigi-ic60---earth-leakage-add-on-block---3p---63a---30ma---a-type/
Acti 9 Technical Catalogue – https://www.se.com/au/en/download/document/SAUM9XED1130718/
 