Socket Outlets - Surface Mount, single 500V 10A - 4 pin

White Electric | Socket Outlets - Surface Mount, single 500V 10A - 4 pin

Socket Outlets - Surface Mount, single 500V 10A - 4 pin

Item Number: 410-WE

Datasheet

Specifications

Design

Product or component type

socket-outlet

Product brand

Clipsal

Sustainable offer status

Green Premium product

Physical

Quantity per set

set of 1

Marking

without marking

Local signalling

without light indicator

Device mounting

surface

Fixing mode

by screws

[In] rated current

10 A

[Ue] rated operational voltage

500 V AC

Depth

38 mm

Fixing center

50 mm

Number of poles

1

Standards

  • AS/NZS 3112
  • AS 3100
  • AS 3109
    • REACh Regulation

      Free of Substances of Very High Concern above the threshold

      EU RoHS Directive

      Compliant

      Mercury free

      Yes

      RoHS exemption information

      Yes

      China RoHS Regulation

      Product out of China RoHS scope. Substance declaration for your information

      Environmental Disclosure

      ENVPEP120506EN

      Material

      Material

      plastic

      Others

      Cover type

      complete housing

      Diameter

      65 mm

      Unit Type of Package 1

      PCE

      Number of Units in Package 1

      1

      Package 1 Weight

      68 g

      Package 1 Height

      50 mm

      Package 1 width

      66 mm

      Package 1 Length

      91 mm
      Show all specifications

      Frequently Asked Questions

      hide show

      Video: How does the PK4MB2HA retaining kit install into the proper QO Single phase 225amp Max. convertible mains, load centers?

      Issue:
      Product Design Features 
       
      Product Line:
      QO Load Centers
       
      Environment:
      Retaining Kits
       
      Cause:
      Application 
       
      Resolution:
      The PK4MB2HA retaining kit secures one QO 2-pole branch circuit breaker with or without electrical accessories to the Right side of the interior when used as a Back-Fed Main Breaker.
      This retaining kit can ONLY be used for QO, 1phase, 150-225amp, Convertible main load centers, Series S01 and S02 and Plug-On Neutral Series S06 Load Centers.
      The retaining bracket will mount over the face of the back-fed branch breaker and get secured using the single interior mounting screw that comes with the kit.
      NOTE: QO-GFI and QO-AFI branch circuit breakers are NOT suitable for use as back-fed main circuit breakers.

      The attached video is ONLY to supplement the INSTRUCTIONS that come with the kit. PLEASE make sure to read the instructions and all the below Safety Information that is located in the instructions BEFORE working on any electrical equipment.
      A pdf copy of the complete instructions is attached below the video.


      Make sure to turn OFF ALL Power supplying the equipment and verify the power is OFF using a properly rated voltage sensing device, BEFORE working on or with electrical equipment. 
      1) Once all Safety steps are followed, begin the kit installation by following the instructions.
      2) Make sure to obtain the correct 2-pole, QO branch breaker to be used as the back-fed Main and DO NOT exceed the maximum rating marked on each load center.
      3) As shown in step 2, on page 2 of the intructions, remove and discard the interior mounting screw(Fig. 1) 
      4) Install the appropriate  QO back-fed branch breaker ONLY in positions 2-4 (The first two positions in the upper right side of the interior)
      5) Center the retaining bracket over the breaker to be used as the back-fed breaker and press down against the face of the retaining bracket to seal it against the breaker.
      6) Secure the retaining bracket to the base with the new interior mounting screw provided in the kit and torque to 35 lb-in (4 N-m)
      7) Remove the backing of the wiring diagram label that comes in the kit, to expose the adhesive and attach the label to the inside of the load center enclosure or to the back of the cover.

      NOTE: PLEASE READ ALL INSTRUCTIONS AND SAFETY INFORMATION THAT COME WITH THE KIT AND NEVER WORK ON ENERGIZED EQUIPMENT.

      What is the replacement AC coil for CAD32 and CAD50 relay?

      Issue:
      AC coil replacement for CAD32 and CAD50

      Product Line:
      Relays

      Environment:
      Tesys CAD Control Relays

      Cause:
      Product selection

      Resolution:
      Volt = coil part number
      12 = LXD1J7
      21 = LXD1Z7
      24 = LXD1B7
      32 = LXD1C7
      36 = LXD1CC7
      42 = LXD1D7
      48 = LXD1E7
      60 = LXD1EE7
      100 = LXD1K7
      110 = LXD1F7
      115 = LXD1FE7
      120 = LXD1G7
      127 = LXD1FC7
      200 = LXD1L7
      208 = LXD1LL7
      220/230 = LXD1M7
      230 595 21 LXD1P7
      230/240 = LXD1U7
      277 781 30 LXD1W7
      380/400 = LXD1Q7
      400 = LXD1V7
      415 = LXD1N7
      440 = LXD1R7
      480 = LXD1T7
      600 = LXD1X7
      690 = LXD1Y7

       

      What is the part number for a 413 surface socket with 4 flat pins?

      The part number is 410 (Single Socket Outlet, 500VAC, 10A, 4 Pin).

      image.png

      Please go to the website via the following links below and check under the Documentation Tab for more information.

      Australia - https://www.clipsal.com/products/detail?CatNo=410&itemno=410-WE&backto=/search?q=410&tab-document-1=0
      New Zealand - https://www.pdl.co.nz/products/detail?CatNo=410&itemno=410-WE&backto=/search?q=410

      What is the plug to fit a 410-WE?

      The Plug to suit is part 439/4

      How to locate Schneider North America Dual Technology (Passive Infrared and Ultrasonic) Line Voltage Ceiling Mount Occupancy Sensor documentation?

      Issue:
      When searching for Schneider Electric North America Dual Technology Ceiling Mounted Line Voltage Occupancy Sensor products documentation for a new or existing installation, assistance is available using online tools and local authorized distributors.

      Product Line:
      Schneider Electric North America  Dual Technology Ceiling Mounted  Line Voltage  Occupancy Sensor (SLSCLD2000) products

      Environment:
      Schneider Electric North America Ceiling Mounted Line Voltage Occupancy Sensor (SLSCLD2000) products sold in the United States

      Cause:
      Selecting the correct Dual Technology Ceiling Mounted Line Voltage Occupancy Sensor (SLSCLD2000) product documentation for a new and existing installation involves many factors. Both online and phone assistance are available to help you.

      Resolution:
      For help when searching for Dual Technology Ceiling Mounted Line Voltage Occupancy Sensor (SLSCLD2000) products documentation, use the following links:

      Also Note: As of March 1, 2015 all US Lighting Control products (EXCEPT Powerlink and MVP panels) will enter their obsolescence phase and will no longer be purchasable for new orders. Management of the Prosumer Business has made a strategic decision to stop the Lighting Control initiative and concentrate our effort in new businesses with higher growth potential – Connected Home, Building Control in small buildings, and Electric Vehicle solutions. See FA241002 for details.

      (1) Our Product web site, at this link.
      https://m.lightingcontrol.schneider-electric.com/product.cfm?pid=51

      (2) Our Online Digest, at this link, shows specific catalog numbers of many of our products.
      www.schneider-electric.us/sites/us/en/support/product-support-resources/online-catalog.page

      (2a) Our Lighting Control section of the Online Digest, at this link, shows specific catalog number of our Lighting Control products.
      https://editiondigital.net/publication/?i=150046

      (3) Further assistance is available from a local authorized Schneider Electric Distributor, using our Distributor Locator at the below link:
      www.schneider-electric.us/sites/us/en/support/distributor-locator/power-industry-locator.page

      All the above tools may be found by visiting our US Home Page.
      www.schneider-electric.com/site/home/index.cfm/us/

      My lights won't dim correctly on a C-Bus Leading Edge Dimmer?

      Does this installation have 3 Phase power??

      If so, check that the 'Control' side and the 'Switching' Side of the Leading Edge Dimmer are connected on the same voltage phase! You are not able to have a separate voltage phase on either of these connections as this unit is not internally connected...

      See, Notes: on page 5 of the linked document

      image.png

      If this installation is a single phase configuration, check the Lighting Driver to make sure this is dimmable and is a Leading Edge driver.

      Some poor quality Lighting Drivers will result in a staggered or erratic dimming experience, we'd suggest trying other brands of drivers in this case, if the driver is built into the light fitting itself then we'd suggest trying a whole new fitting.

      Click HERE for the installation Instructions
      Show More