sock c/extn 0.75x1sq flex 250v
sock c/extn 0.75x1sq flex 250v
sock c/extn 0.75x1sq flex 250v
sock c/extn 0.75x1sq flex 250v

SOCKET CORD EXTENSION 0.75X1SQ FLEXIBLE 250V

Catalogue Number: 438
sock c/extn 0.75x1sq flex 250v
sock c/extn 0.75x1sq flex 250v
sock c/extn 0.75x1sq flex 250v
sock c/extn 0.75x1sq flex 250v
Colour: White Electric
Colour: Per UOM Std.
  • Grey 1 PCE 1
  • Transparent 1 PCE 1
  • White Electric 1 PCE 1

Specifications

hide show
Range of product
Standard Series
Product brand
Clipsal
Quantity per set
set of 1
Cover type
complete housing
Marking
without marking
Local signalling
without light indicator
Material
PVC (polyvinyl chloride)
[In] rated current
10 A
[Ue] rated operational voltage
250 V AC
Depth
71 mm
Diameter
43 mm
Standards
  • AS/NZS 3112
  • AS 3100
  • AS 3109
  • AS/NZS 3122:approval number S/1
    • REACh Regulation
      Free of Substances of Very High Concern above the threshold
      EU RoHS Directive
      Compliant
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information

      Documents & downloads

      hide show
      Filter items
      • All

      • CAD Files and Packs

      • Installation Instruction

      • Product Environmental

      • Specifications

      • Certificates (MSDS)

      Frequently Asked Questions

      hide show

      Do you have a 32A version of a 438 extension socket?

      No, the largest rated version of a 438 extension socket is the 438/20 which is 20A.

      Does Clipsal have a 1438 in 20 amp?

      No, but we have a 438 in 20 amp or there is the 56 series which could do the job.

      For more information, please refer to the link:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=438/20 

      Is the 488 tester still available

      No it has been replaced by the spark-e-mate 493BTL and 493BTL I

      What is the socket for 418SL or 439SL

      438L - Socket PVD 10A suit 1mm ord.duty flex, rnd Earth socket.

      What is the 600 series adaptor to convert a 149 to 1 gang

       It is a PDL 538

      Who is stocking Elliwell products ?

      Smith Elements & Controls  - 0800 437 638

       

      What is the code for a 2-gang conversion plate for PDL 500/600 series?

      Part code is PDL 538

      What are the dimensions of chassis PAN16 ?

      Dimensions =  PAN16   - showing total width as 232 - Height = 432

      what is the part no for a plug like 439 which is 20A rated?

      the part no is 1439/20

      please use this link for further information https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=1439/20

      User-added image

      Can I purchase a lockable version of the Clipsal 435

      No, but you can use the PDL 56 Series 56AI310 and 56CSC310

      Do you do a 238 mounting block with a 50mm entry?

      No, unfortunately the 238/25 has the largest conduit entry with a 25mm entry at each end.

      For further information please visit https://www.clipsal.com/Trade/search-results?q=238/25

      Does Clipsal do a 238 with 25mm entries, top and bottom?

      No we don't. The closest we get is the 238A/25 with one 25 entry on the top.

      PME 7.2.2 web application HTTP Error 500.21 - Internal Server Error Handler "PageHandlerFactory-Integrated" has a bad module "ManagedPipelineHandler" in its module list

      Issue
      Attempting to access the PME 7.2.2 Web application in a browser yields the following error:
      [Error Summary]
      HTTP Error 500.21 - Internal Server Error
      Handler "PageHandlerFactory-Integrated" has a bad module "ManagedPipelineHandler" in its module list

      Environment
      PME 7.2.2 Web Applications

      Cause
      .NET was not registered with IIS during the upgrade or re-install.

      Resolution
      Run the following command in the Windows command line or powershell as administrator to re-install .NET.
      %windir%\Microsoft.NET\Framework\v4.0.30319\aspnet_regiis.exe -i

      Where to find settings manual for MiCOM x3x Series?

      Issue 
      Need more information on settings on the MiCOM x3x.

      Product Line  
      MiCOM P13x
      MiCOM P23x
      MiCOM P43x
      MiCOM P53x
      MiCOM P63x

      Environment  
      Setting or Troubling settings

      Resolution    
      All the settings, measurements, recordings with option and configuration tables plus IEC - 103 telegram documentation/menu database can all be found in the Data Model Explorer.
      To get the Data Model Explorer needed just type in the MiCOM model need.  For example in Google type in MiCOM P438 for Data Model Explorer.  Click on the Schneider Electric result for the MiCOM P438 Data Model Explorer.
      It will bring up the following Data Model Explorer page https://www.schneider-electric.com/en/download/document/P438_DataModelExplorer_EN/
      On the site download the P438 that is needed. 
       

      Does the Telemecanique Nautilus pressure switch with a range of 435 - 7250psi have a replacement diaphragm?

      The pressure switch with 435 - 7250 psi is actually piston actuated, therefore we do not have a replacement diaphragm for it.

      What is the part number for a 238 in black?

      The part number for a 238 in black is 238-BK.

      Some of the key features are:
      • 1 gang
      • 84 mm mounting center
      • Horizontal and vertical mounting direction
      • 2 way
      • Suitable for 1 outlet
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=238




       

      Do you have a single phase output Altivar ATV18 drive?

      Issue: Do you have a single phase output Altivar ATV18 drive?
       
      Product Line: ATV18
       
      Environment: All
       
      Cause: N/A
       
      Resolution: No.


       

      Is the Altivar ATV18 a constant and variable torque unit.

      Issue: Is the Altivar ATV18 a constant and variable torque unit.
       
      Product Line: ATV18
       
      Environment: All
       
      Cause: N/A
       
      Resolution: It is both a constant and variable torque unit.


       

      Can the Altivar ATV18 freewheel stop?

      Issue: Can the Altivar ATV18 freewheel stop?
       
      Product Line: ATV18
       
      Environment: All
       
      Cause: N/A
       
      Resolution: Yes, in level 2 paramters disable the bra function which stands for brake ramp adaptation.


       

      Does the Altivar ATV18 unit have tachometer feedback?

      Issue: Does the Altivar ATV18 unit have tachometer feedback?
       
      Product Line: ATV18
       
      Environment: All
       
      Cause: N/A
       
      Resolution: No, it does not have tachometer feedback.


       

      Do the 448 and 449A, both suit the Prestige range?

      Yes, they do suit the Prestige Range.

      For more information, please refer to the link:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=448 
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=449A 



       

      Is there a 435VFS15 in 10 A?

      Either a 435 which isnt water proof or a 56AI310

      What are the maximum IO counts for the M251 using the TM3 Expansion modules?

      For discrete IO modules, you can have up to 488 digital IO counts.
      For Analog IO modules, you can have up to 114 analog IO counts.

      What is the air flow of the 6500ADS?

      The air flow of the 6500ADS is 338 cubic meters per hour or 290 cubic meters per hour if you have a backdraught shutter fittered.

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=6500ADS

      How can the Altivar ATV18 be wired for 3 wire control?

      Issue: How can the Altivar ATV18 be wired for 3 wire control?
       
      Product Line: ATV18
       
      Environment: All
       
      Cause: N/A
       
      Resolution: It is a 2 wire control only device. Will need to wire 3 wire externally using relay logic.


       

      Are the Altivar ATV18 fault contacts dry?

      Issue:
      Are the Altivar ATV18 fault contacts dry?
       
      Product Line:
      ATV18
       
      Environment:
      All
       
      Cause:
      N/A
       
      Resolution: 
      Yes, you can supply up to 250 volts AC at .5 amp.


       

      How do you factory reset the Altivar ATV18 unit?

      Issue: How do you factory reset the Altivar ATV18 unit?
       
      Product Line: ATV18
       
      Environment: All
       
      Cause: Factory reset
       
      Resolution: First, set parameter L2A to YES so that you can access level 2. Then set parameter FCS to Yes to program the unit for Total factory settings


       

      What type of fusing is to be used on the Altivar ATV18 unit?

      Issue:What type of fusing is to be used on the Altivar ATV18 unit?
       
      Product Line:ATV18
       
      Environment:All
       
      Cause:N/A
       
      Resolution:Class J or CC Both are fast acting.


       

      Do we have an encoder feedback for the Altivar ATV18 drive.

      Issue: Do we have an encoder feedback for the Altivar ATV18 drive.
       
      Product Line: ATV18
       
      Environment: All
       
      Cause: N/A
       
      Resolution: No, we do not have a Encoder Feedback card for this drive.


       

      Is there a 448 mounting block available in black?

      No, unfortunately this mounting block is unavailable in black. As an alternative we can do the 448SD Mounting block in black however it has a depth of 14mm a pose to 28mm.
      Some of the key features are:

      • Large size format, deep mounting
      • With metal inserts, 16 mounting screw positions
      • Various colours available
      For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=448SD

      What is the code for the 240VAC Coil for the LC1D32 Contactor ?

      Part Code = LXD1U7 
      The LXD1U7 also fits the LC1D09 - D38 Contactors

      What mounting block should be used with a large plate Prestige switch?

      The 448 should be used with a large plate Prestige switch.

      What is the part number for 50 X 150 TALplus / Moduline duct?

      The part number for 50 X 150 duct is PL50150D*

       

      *=Colour code

      For further information see page 433, 434 Of the Trade Product Edition 93

      or page 474 of Edition 92

      or visit https://updates.clipsal.com/ClipsalOnline/Files/Brochures/CMS0005.pdf

      Is there a 435VHS in 10A?

      no unfortunately. however we do offer a 435 but that does not have an IP rating. if you need an IP rating you can use the 56AI310 which is a 56 series apliance inlet rated to 10 A and has an IP rating of IP56.

      Which SCEM card is associated with each series of recloser/sectionalizer?

      Product Line
      Recloser

      Resolution
      Refer to the below table:

      Resloser Series SCEM Card
      N Series (up to 27kV) SCEM 11A
      N Series (38 kV) SCEM 11C
      U Series  SCEM 11B
      W Series SCEM 11D
      RL Series SCEM 12

      How do I set up 3 preset speeds in the Altivar ATV18?

      Issue: How do I set up 3 preset speeds in the Altivar ATV18?
       
      Product Line: ATV18
       
      Environment: All
       
      Cause: N/A
       
      Resolution: Told him to first clear all Logic Input settings. Then program LI3 for PS4, then program LI2 for PS2, the sequencing is very important. Then set SP3 and SP4 for the preset speeds.


       

      Can you use the Altivar ATV18 on single phase motors?

      Issue: Can you use the Altivar ATV18 on single phase motors?
       
      Product Line: ATV18
       
      Environment: All
       
      Cause: N/A
       
      Resolution: No, the biggest reason is that most single phase motors have a capacative start. They can only run in one direction and when you slow motor to 70% or less, the capacitor comes back into the circuit.


       

      Can the torque limitations go up to 200% on the Altivar ATV18?

      Issue:  Can the torque limitations go up to 200% on the Altivar ATV18?
       
      Product Line:  ATV18
       
      Environment:  All
       
      Cause:  N/A
       
      Resolution:  The torque limitation of 150% for CT is just a function of the current draw. If the drive is upsized for a higher current rating then the torque can be increased as well.


       

      Are the LC1D40 thru LC1D150 Available With a Low Consumption DC Coil?

      Issue: 
      Looking for a higher amperage rated contactor with lox consumption dc coil.

      Product Line:
      Contactors and Starters

      Environment:
      D-Line Contactors
       
      Resolution: 
      No. Low consumption coils are available only on LC1D09 thru D38 contactors.

      Do you have a deeper version of the 448SD, large format, mounting block?

      Yes, we do have a deeper version of the 448SD, large format, mounting block. The part number is 448.

      The depth of the 448SD is 14mm where as the 448 has a depth of 28mm.

      EGX300 - iEM335X not showing Real Time Data due to Device Template Error

      Issue:
      All the real time data from iEM3355 are shown N/A on Monitor tab of EGX300 with latest firmware and disk image 4.38 installed.
      Related case in bfo 15520706.
       
      Answer:
      The firmeare wasn't upgraed successfully, the [oldversion].upd file can still be found in root folder of EGX300 FTP site.
      The issue can be addressed by removing the [oldversion].upd file and reuploading the newest disk image .upd file into FTP site again.
       

      Does the 56AI320 have round or flat pins?

      The 56AI320 is not available with flat pins.

      Some of the key features are:
      • 3 round pins
      • 204 mm Height x 101 mm Width x 138 mm Depth
      • 2.5 - 6 mm conductor terminal

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56AI320
       

       

      At which DC bus voltage DBR (Dynamic Braking Resistor) triggers in Lexium 32 drives

      Braking resistor switch on voltage is fixed by hardware and it is not configurable in LXM32.
      For LXM32___M2 range threshold is 430 vdc if parameter DCbus_compat  = 0 (default) and 395 vdc if parameter DCbus_compat = 1
      For LXM32___N4 range threshold is 780 vdc irrespective of parameter DCbus_compat settings.

       

      Changing Power Flow Sign remotely on a Compact NSX

      For remote sites there is a way of connecting remotely to a Micrologic unit to change the Power Flow Sign.
       
      On page 118 of the following user guide is talks about Power Flow Sign and has a command code of 47240. This configures the power flow sign.

      https://www.schneider-electric.com/en/download/document/DOCA0091EN/

      Page 138 of the same guide explains how to do this configuration.

       

      Do you have a round 15A, socket inlet?

      Yes, we do have a round 15A socket inlet. The part number is 435A15.

      Some of the key features are:
      • Terminal bores accommodate 3 x 2.5 mmsq cables
      • Back terminal cover
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=435A15.
       

      Where is the Unit ID located in MBP_MSTR function block?

      Title
      MBP_MSTR Unit ID location
       
      Issue
      MBP_MSTR function required location of the Unit ID value.
       
      Product Line
      Quantum , Momentum PLC
       
      Environment
      Unity
       
      Cause
      N/A
       
      Resolution
      The MBP_MSTR function requires that the Unit ID location be in low byte of 5th word of control block.The Unit ID would refer to the unit's Modbus address.

      I have an LC1D TeSys D-Line contactor. Which are the coil terminals?

      Issue:
      I have an LC1D TeSys D-Line contactor.  Which are the coil terminals?

      Product Line:
      D Line contactors.

      Environment:
      Products sold in the United States.

      Cause:
      Product features.

      Resolution:
      The coil terminals are the ones labelled A1 and A2.


      CTA-ID : 2011973

      Will the 437PR plug coupling ring screw on to the 56 series socket outlets?

      Yes, this part will screw on to the 56 Series oulets as well as the 473P.

      Some of the key features are:
      • Female threads 2 inch B.S.P (11 T.P.I.), suits 439 Series, 437R Coupling Ring, Single Phase 56SO310 Series sockets, 56C310 Series combinations and SS15 Series suspension switch sockets.
      For further information is https://www.clipsal.com/Trade/Products/ProductDetail?catno=437PR


       

      What is difference between 437P & 437PR?

      The part 437P is half coupling.
       
      437PR 437P
      • Suits 437S socket coupling
      • Female threads 2 inch B.S.P (11 T.P.I.), suits 439 Series, 437R Coupling Ring, Single Phase 56SO310 Series sockets, 56C310 Series combinations and SS15 Series suspension switch sockets.

      Configuring SeaLevel 450 Relay I/O Device within Netbotz

      Issue:

      Configuring SeaLevel 450 Relay I/O Device within Netbotz

      Product Line:

      NetBotz
      Sealevel

      Environment:

      NetBotz version 2 and 3
      Sealevel 450

      Cause:

      3rd party device configuration.

      Resolution:

      Once the I/O Device is connected to the Appliance, configuration for the Seal/O device can be done by the following:

      1. Launch the Advanced View on the Appliance.
      2. Double click the 'Serial Devices' Applet
      3. In the drop-down menu, select the Sea-Level Product >> SeaLevel SeaI/O 450.
      4. Then select 'OK'


      Show More