block mounting pvc 98x45mm

BLOCK MOUNTING PVC 98X45MM

Catalogue Number: 47
block mounting pvc 98x45mm
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE 1

Specifications

hide show
Product brand
Clipsal
REACh Regulation
Free of Substances of Very High Concern above the threshold
REACh free of SVHC
Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile
N/A

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Installation Instruction

  • Product Environmental

  • Specifications

  • Certificates (MSDS)

Frequently Asked Questions

hide show

What is alarm 47 on the Series 2000 Circuit Monitor (CM2000)?

Issue:
A CM2000 series circuit monitor is displaying alarm code 47 on the front display.

Product Line:
CM2000 Series Circuit Monitor

Environment:
Onboard Alarms

Cause:
Alarm code 47 is defined as "Suspended Sag/Swell". The alarm is to identify an excessive number of Sag/Swell events being generated on the meter.

An "excessive number" of Sag/Swell events is defined as:
More than 48 events total from all Sag/Swell Alarms in any 500ms period, or more than 6 events from any single Sag/Swell Alarm in any 500ms period.

Alarm code 47 is active when event 47 is true which occurs when register 2038 on the meter is not equal to zero.  If the user disables alarm 47 without clearing Register 2038, the alarm will immediately be re-enabled and asserted as true.

Resolution:
To clear alarm 47, write a 0 to register 2038.

To learn how to read and write registers using the front panel of the CM2000 series meter, please refer to KB article FA211912
To learn about other CM2000 alarm codes, please refer to the KB article FA218966.

 

Is the ABL8RPS24030 okay for 60 hertz?

Yes they are have a Network Frequency range of 47 - 63 Hz
As shown on attached Data sheet

ATO dumps the load as the load increases

Issue:
ATO system dumps the plant load when on generator power, as the load increases

Product Line:
Premium PLC

Cause:
47 pickup is too low at 2%

Resolution:
Increase 47 pickup to 6%

What are the hole sizes and dimensions of the AR8395 copper bus bar?

Issue:
A customer wants to use 2-hole lugs on the ground bar

Product Line:
NetShelter Bus Bar

Environment: 
AR8395

Cause:
Grounding / bonding is required

Resolution: 
The AR8395 has the following holes available: 
47 holes threaded #10-32, spaced 18 cm center to center. 
25 holes at 5.5 cm and 9 holes at 7.9 cm, spaced at 25 cm center to center. 
 

Is There a lens avaliable for XUY40327350?

XUY40327350 is a high temperature fiber specially manufactured for one of our customer (exclusive sales), so to get this product or informations about it, you have to contact directly the company : we are not authorized to provide any information about this product.

For further information please visit https://www.schneider-electric.com.au

Can TeSys T be used downstream of Altivar range Variable Speed Drive.

The Current Transformers (CTs) of TeSys T are deigned to work under the frequency range between 47 to 63 Hz only. 

However, the output frequency range of Altivar Variable Speed Drive varies from 0 Hz to 400 Hz. So when the TeSys T is placed in the downstream of the Variable Speed Drive, the CTs of TeSys T will not be able to sense the current values correctly, as the frequency of the current is not as per design specifications.
 
This will affect the TeSys T working and the outcome will not be the actual.  So, it is not recommended to use the TeSys T in downstream of the Altivar Range Variable Speed Drives.
Show More