Mounting block 1 gang - to suit cat. no. 16 combination

White Electric | Mounting block 1 gang - to suit cat. no. 16 combination

Mounting block 1 gang - to suit cat. no. 16 combination

Item Number: 47-WE

Datasheet

Specifications

Design

Product brand

Clipsal

Sustainable offer status

Green Premium product

Physical

REACh Regulation

Free of Substances of Very High Concern above the threshold

REACh free of SVHC

Yes

EU RoHS Directive

Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free

Yes

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Environmental Disclosure

ENVPEP110719EN

Others

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

36 g

Package 1 Height

25 mm

Package 1 width

103 mm

Package 1 Length

49 mm
Show all specifications

Frequently Asked Questions

hide show

How to Program If-Then-Else Statements in SCADAPack Workbench FBD Language

SCADAPack Workbench supports four standard IEC 61131-3 programming languages for CAM5 and three standard IEC 61131-3 programming languages for CAM3. These languages can be mixed within an application to provide an optimum control strategy.

Typically If-Then-Else Statements are best used with Structured Text Language (ST). In some instances, it may be desired to use these types of statements in a Function Block Diagram (FBD). Although not as elegant as ST, this can be achieved with JUMP's and LABELS in a FBD program.

The below example shows how to create an If-Then_Else statement in both FBD and ST.



























Micrologic P trip unit doesn't display voltage or power measurements.

Issue:
Micrologic P trip unit doesn't display voltage or power measurements.

Product Line:
PowerPact P and R and Masterpact NT and NW circuit breakers

Resolution:
If this P trip unit was upgraded from either a Standard or Ammeter trip unit, then to correct this, add the external voltage sensing (EVS) kit. Use:
S64203 for P frame unit mount or I-Line
S64210 for P frame with motor operator or rotary handle
S64209 for P frame drawout
S64208 for R frame unit mount or I-Line
S47506 for fixed NT or NW breakers
S47507 for drawout NT breakers
S48533 for drawout NW breakers
Refer to Installation Bulletin 48049-339-01 for all of the P and R frame kits.
Refer to Installation Bulletin 48049-296-02 for the fixed NT or NW as well as the drawout NT breakers and 48049-242-02 for the drawout NW breakers.

What are the catalog numbers and available voltages for shunt trip and shunt close accessories for the Masterpact NW?

Product Line:
Circuit Breakers:

Environment:
Applies to Masterpact breakers NW drawout and fixed type.

Resolution:
Shunt Trip, Second Shunt Trip, and Shunt Close
Voltage 50/60 HzT-, W-, & Y-Frame
Fixed
T-Frame
Drawout
W- & Y-Frame
Drawout
12 dcS47359S33809S48490
24–30 ac/dcS47360S33810S48491
48–60 ac/dcS47361S33811S48492
100–130 ac/dcS47362S33812S48493
200–240 ac/dcS47363S33813S48494
277 acS47364S33814S48495
380–480 acS47365S33815S48496

See instruction bulletin, 48049-237-03

What size fuses are used in the ATS48 for the control circuit going to CL1 and CL2?

Issue:
ATS48 fuse size for circuit control going to CL1 and CL2

Product Line:
Altistart 48, ATS48

Environment:
All open style units.  All models, All Serial numbers.

Cause:
Selection of Fuses.

Resolution:

ATS48D17Y and ATS48D22Y we recommend Class CC 600V 0.5 A fuses.

ATS48D32Y, ATS48D38Y, ATS48D47Y, ATS48D62Y, ATS48D75Y, ATS48D88Y, ATS48C11Y, ATS48C14Y, and ATS48C17Y we recommend Class CC 600V 0.6 A fuses.

ATS48C21Y, ATS48C24Y, and ATS48C32Y we recommend Class CC 600V 1.0 A fuses.

ATS48C41Y, ATS48C48Y, ATS48C59Y, ATS48C66Y, ATS48C79Y, ATS48M10Y and ATS48M12Y we recommend Class CC 600V, 1.5 A fuses.

Information provided in Table 31 page 83) of document S1A37491 Altistart 48 Y-range Soft Start Controllers Instruction Bulletin.

Can Multi-9 C60 breakers be continuously loaded to 100% of their rating?

Issue:
Can Multi-9 C60 breakers be continuously loaded to 100% of their rating?

Product Line:
Multi 9 C60 MCB's

Resolution:
UL 489 Listed Multi 9 C60 circuit breakers may be loaded to no more than 80% if used with continuous loads.
UL 1077 recognized supplementary protectors may be operated at 100% of their rating.
IEC 60947-2 C60 breakers may be operated at 100% of their rating.

Is the LAD7B10 a UL and CSA Recognized Component?

Issue:
Is the LAD7B10  UL and CSA recognized?

Product Line:
IEC Overload Mounting Kit

Environment:
IEC Contactors

Cause:
Clarify CSA and UL listing for IEC components

Resolution:
As of 6/30/2016 this device has been UL component recongnized. This device has not been CSA recognized
Show More