Rewireable Plugs, 110V, 10A, 2 Pin, 2 Core, 1mm², Ordinary Duty

White Electric | Rewireable Plugs, 110V, 10A, 2 Pin, 2 Core, 1mm², Ordinary Duty

Rewireable Plugs, 110V, 10A, 2 Pin, 2 Core, 1mm², Ordinary Duty

Item Number: 492-WE

Datasheet

Specifications

Design

Product brand

Clipsal

Colour

body: white electric

Sustainable offer status

Green Premium product

Physical

[In] rated current

10 A

[Ue] rated operational voltage

110 V 50/60 Hz conforming to EN 60309-2

Connections - terminals

screw terminal

REACh Regulation

Free of Substances of Very High Concern above the threshold

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental Disclosure

ENVPEP1605009

Material

Material

plastic

Others

Voltage colour

blue

Plug, socket, control station shape

straight

Duration

6 h

Package 1 Weight

35 g

Package 1 Height

39 mm

Package 1 width

100 mm

Package 1 Length

165 mm
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • Certificates (MSDS)

Frequently Asked Questions

hide show

What are the catalog numbers and available voltages for shunt trip and shunt close accessories for the Masterpact NW?

Product Line:
Circuit Breakers:

Environment:
Applies to Masterpact breakers NW drawout and fixed type.

Resolution:
Shunt Trip, Second Shunt Trip, and Shunt Close
Voltage 50/60 HzT-, W-, & Y-Frame
Fixed
T-Frame
Drawout
W- & Y-Frame
Drawout
12 dcS47359S33809S48490
24–30 ac/dcS47360S33810S48491
48–60 ac/dcS47361S33811S48492
100–130 ac/dcS47362S33812S48493
200–240 ac/dcS47363S33813S48494
277 acS47364S33814S48495
380–480 acS47365S33815S48496

See instruction bulletin, 48049-237-03

What is the operating voltage tolerance, catalog numbers, and clearing times for the Masterpact NT and NW shunt trip and shunt close coils?

Issue:  
What is the operating voltage tolerance, catalog numbers, and clearing times for the Masterpact NT and NW shunt trip and shunt close coils?

Product Line:
Masterpact NT NW

Resolution:
Shunt trip:  operating threshold is 0.7x to 1.1x Vn (nominal voltage)
Shunt close:  operating threshold is 0.85x to 1.1x Vn
Catalog numbers are the same for MX and MN (shunt trip and shunt close) devices; function is determined by placement in the breaker.
 
Voltage (V) at 50/60 HzT-, W-, & Y-Frame FixedT-Frame DrawoutW- & Y-Frame Drawout
12 DCS47359S33809S48490
24-30 AC/DCS47360S33810S48491
48-60 AC/DCS47361S33811S48492
100-130 AC/DCS47362S33812S48493
200-240 AC/DCS47363S33813S48494
277 ACS47364S33814S48495
380-480 ACS47365S33815S48496

MX operating time at Vn:  50 ms ±10 (NW and NT)
XF operating time at Vn:  
70 ms ±10 (NW ≤ 4000 A)
80 ms ±10 (NW > 4000 A)
55 ms (NT)

NOTE:  Shunt trip (MX) and shunt close (XF) circuits must be energized for a minimum of 200 ms. In other words, don't use an impulse signal. Use a signal of at least 200ms.

What is the female version of a 492

The part number part is 438/2
Flexible Cord Extension Socket with two parallel pins, 250V, 10A rating

Does the Clipsal 438/2 suit the 492

The 438/2 does suit the 492. 

Why is my Wiser Air (North America model) account showing unable to reach device? - Wiser Air EOL (North America models) -

Product Line:
Wiser Air (North America model)
Resolution:
End of Life Announcement for Wiser Air Thermostat
 
Schneider Electric announces the end-of-life and end-of-support in North America for the Wiser Air Thermostat and the decommissioning of the Wiser Air Thermostat mobile and web applications.
 
The Schneider Electric Support Team will continue to help customers still using the product until September 30, 2021.
 
 
 
 
Wiser Air models
 
 
Eligible Wiser Air Thermostat models:
 
  • WISERAIR10BLKU
  • WISERAIR10BLKUS
  • WISERAIR10WHTUS
  • WISERAIR10BLKCA
  • WISERAIR10WHTCA

Wiser Air can only be controlled via the thermostat if the application servers are down or unable to access the Wiser Air account.

 

How to backup and restore Dalibuilding database?

Require SQL Server Management Studio backup and Attach Databases in Management Studio

To Backup > Right click on the database and select Task > Backup

Select Location and Ok .BAK file

 

to Restore, Right click > Restore Database

Choose Device > click the three dot

Then Click Add > 

 

Select the backup .BAK then Ok > Ok then OK

Show More