493 SPARKEMATE MULTI TESTER

493 SPARKEMATE MULTI TESTER

493 SPARKEMATE MULTI TESTER

Item Number: 493

Datasheet

Specifications

Design

Range

Clipsal

Product brand

Clipsal

Physical

EU RoHS Directive

Under investigation

Others

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

1.32 kg

Package 1 Height

11.8 cm

Package 1 width

13.8 cm

Package 1 Length

25.2 cm
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • Declaration of Conformity

Frequently Asked Questions

hide show

What are the catalog numbers and available voltages for shunt trip and shunt close accessories for the Masterpact NW?

Product Line:
Circuit Breakers

Resolution:
Shunt Trip, Second Shunt Trip, and Shunt Close
Voltage 50/60 HzT-, W-, & Y-Frame
Fixed
T-Frame
Drawout
W- & Y-Frame
Drawout
12 dcS47359S33809S48490
24–30 ac/dcS47360S33810S48491
48–60 ac/dcS47361S33811S48492
100–130 ac/dcS47362S33812S48493
200–240 ac/dcS47363S33813S48494
277 acS47364S33814S48495
380–480 acS47365S33815S48496

See instruction bulletin, 48049-237-03

For VA consumption

What is the operating voltage tolerance, catalog numbers, and clearing times for the Masterpact NT and NW shunt trip and shunt close coils?

Issue:  
What is the operating voltage tolerance, catalog numbers, and clearing times for the Masterpact NT and NW shunt trip and shunt close coils?

Product Line:
Masterpact NT NW

Resolution:
Shunt trip: operating threshold is 0.7x to 1.1x Vn (nominal voltage)
Shunt close: operating threshold is 0.85x to 1.1x Vn
Catalog numbers are the same for MX and MN (shunt trip and shunt close) devices; function is determined by placement in the breaker.
 
Voltage (V) at 50/60 HzT-, W-, & Y-Frame FixedT-Frame DrawoutW- & Y-Frame Drawout
12 DCS47359S33809S48490
24-30 AC/DCS47360S33810S48491
48-60 AC/DCS47361S33811S48492
100-130 AC/DCS47362S33812S48493
200-240 AC/DCS47363S33813S48494
277 ACS47364S33814S48495
380-480 ACS47365S33815S48496

MX operating time at Vn:  50 ms ±10 (NW and NT)
XF operating time at Vn:  
70 ms ±10 (NW ≤ 4000 A)
80 ms ±10 (NW > 4000 A)
55 ms (NT)

NOTE:  Shunt trip (MX) and shunt close (XF) circuits must be energized for a minimum of 200 ms. In other words, don't use an impulse signal. Use a signal of at least 200 ms.

What is part number for leads to suit 493?

The part number for leads to suit 493 is a 493L.
image.png

Please go to the following links below and check under the Documentation Tab for more information.

Australia - https://www.clipsal.com/products/detail?CatNo=493L&itemno=493L&backto=/search?q=493L&tab-document-1=0
New Zealand - https://www.pdl.co.nz/products/detail?CatNo=493L&itemno=493L&backto=/search?q=493L&tab-document-1=0

What comes in the 493L

Alligator clips, prongs, and lead.

image.png

Please go to the following links below and check under the Documentation Tab for more information.

Australia - https://www.clipsal.com/products/detail?CatNo=493L&itemno=493L&backto=/search?q=493L&tab-document-1=0
New Zealand - https://www.pdl.co.nz/products/detail?CatNo=493L&itemno=493L&backto=/search?q=493L&tab-document-1=0

How do you perform an RCD test using the 493 Spark-e-Mate installation tester?


Please view this video.

How do I conduct a Fault Loop Impedance Test using a 493 Spark-e-Mate installation tester?


Please view the video.
Show More