6 key input glass fascia- pw

6 GANG GLASS FACIA CREAM. 5086F,PW REPLACES 5086F,SF.

Catalogue Number: 5086F

Discontinued

6 key input glass fascia- pw
Colour: Pure White
Colour: Per UOM Std.
  • Pure White 1 PCE 1

Specifications

hide show
Range of product
  • C-Bus
  • Australian Series
  • Saturn Series
    • Product brand
      Clipsal
      Number of gangs
      6 gangs
      Product destination
      switch
      Material
      glass
      Control type
      button
      Marking
      without marking
      Mounting position
      vertical
      Fixing center
      84 mm
      Length
      116 mm
      Width
      76 mm
      Depth
      12 mm
      EU RoHS Directive
      Pro-active compliance (Product out of EU RoHS legal scope)
      Circularity Profile
      ENVEOLI121001EN_V1

      Documents & downloads

      hide show
      Filter items
      • All

      • CAD Files and Packs

      • Product Brochures

      • Installation Instruction

      • Product Environmental

      • End of Life Manual

      • Operating Manuals

      • System User Guide

      • Specifications

      • Software - Released

      Frequently Asked Questions

      hide show

      What is the VA rating of a 9001KM transformer light module?

      Issue:
      What is the VA rating of a 9001KM transformer light module?

      Product Line:
      Harmony Pushbuttons

      Environment:
      All Products

      Cause:
      Product Features

      Resolution:
      9001 KM2 110-120 volt 25-30 hertz      2.2 VA
      9001 KM1 110-120 volt 50-60 hertz      2.4 VA
      9001 KM3 208-220 volt 50-60 hertz      2.5 VA
      9001 KM4 220-240 volt 25-30 hertz      2.2 VA
      9001 KM7 220-240 volt 50-60 hertz      2.0 VA
      9001 KM8 277 volt 50-60 hertz             2.4 VA
      9001 KM5 380-480 volt 50-60 hertz      2.8 VA
      9001 KM6 550-600 volt 50-60 hertz      2.5 VA

      Motor power in kW of a LE1M35U705

      0.25 kW at 415 V AC 50/60 Hz
      0.25 kW at 380...400 V AC 50/60 Hz
      0.12 kW at 240 V AC 50/60 Hz
      0.12 kW at 220...230 V AC 50/60 Hz
       

      What is the part number for the Fascia only on a Cbus Saturn 4 gang plate ?

      The part number will be 5084F- and then colour reference eg 5084F-PW for Pure White Fascia

      Video: How to I replace the modules in my Smart-UPS Modular UPS?

      Issue:
      Replacing modules in Smart-UPS Modular units.

      Product Line:
      Smart-UPS

      Environment:
      All "SUM" models, All Serial Numbers

      Cause:
      Smart-UPS Modular models feature user replaceable Power and Battery modules.

      Resolution:
      The following video details the installation and removal of modules in a Smart-UPS Modular UPS:

      Can the VLT Ref 16060 (analogue voltmeter) be used on DC voltages?

      Goals and Symptoms

      Can the VLT Ref 16060 (analog voltmeter) be used on DC voltages.

      Causes and Fixes

      This VLT ref 16060 is usable for AC voltages only within the range of 50-60 Hz. You cannot use it on DC voltages.


      Legacy KB System (APS) Data: RESL201042 V1.0, Originally authored by KBAdPM on 01/20/2010, Last Edited by KBAdPM on 01/20/2010
      Related ranges: Analog Amp - voltmeters

      Carrier 30RA010-055 AquaSnap® Air-Cooled Chillers with ComfortLink™ Controls 50/60 Hz


      Issue:
      This article contains the manuals for Carrier 30RA010-055 AquaSnap® Air-Cooled Chillers with ComfortLink™ Controls 50/60 Hz

      Product line: 
      Carrier 30RA010-055.

      Environment: 
      All Serial Numbers. 

      Cause: 
      Controls, Start-Up, Operation, Service, and Troubleshooting.

      Resolution:  
      See attached manuals
      Show More