C-Bus Bus Coupler Input Unit, 4 Channel, Support on-Board Scenes

C-Bus Bus Coupler Input Unit, 4 Channel, Support on-Board Scenes

C-Bus Bus Coupler Input Unit, 4 Channel, Support on-Board Scenes

Item Number: 5104BCL

Datasheet

Specifications

Design

Sustainable offer status

Green Premium product

Range of product

C-Bus

Product brand

Clipsal

Physical

REACh Regulation

Free of Substances of Very High Concern above the threshold

REACh free of SVHC

Yes

EU RoHS Directive

Compliant

Toxic heavy metal free

Yes

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Environmental Disclosure

ENVPEP111268EN

Circularity Profile

ENVEOLI111254EN

Others

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

74.0 g

Package 1 Height

4.315 cm

Package 1 width

8.617 cm

Package 1 Length

13.13 cm

Unit Type of Package 2

BB1

Number of Units in Package 2

5

Package 2 Weight

470.0 g

Package 2 Height

9.5 cm

Package 2 width

14 cm

Package 2 Length

23.6 cm

Unit Type of Package 3

CAR

Number of Units in Package 3

50

Package 3 Weight

5.37 kg

Package 3 Height

27.4 cm

Package 3 width

37.1 cm

Package 3 Length

50.1 cm
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Installation Instruction

  • Specifications

  • Application Solutions

  • Declaration of Conformity

  • Software - Archive

  • Software - Release

Frequently Asked Questions

hide show

Is the 5104BCL non isolated?

As stated in section 2.0 of installation instructions:

"Then input channels of the 5104BCL are NOT isolated"

See below for more information:
https://download.schneider-electric.com/files?p_Doc_Ref=5104BCL_Install_Instr_F1874&p_File_Ext=.PDF

Can you send a command to a C-Bus Coupler to switch a contact like an Alarm AUX, or Roller Door motor?

No, the C-Bus Coupler is not able to output to or control a connection to it, the Bus Coupler will only recognize a contact closure and then send a command onto the C-Bus to perform an action.

These are typically used for a status of a contact being either open or closed, or when a C-Bus switch is not suitable in the environment. For example you might need a IP rated switch in a cool room, this mechanical switch will connect to the inputs of the Bus Coupler which in turn when switched will send a command onto C-Bus.

How can you create a C-Bus Mech that is IP Rated?

5104BCL coupling unit will fit into a PDL56PB1GNLEGY + PDL56E1GY.