C-Bus Network Automation Controller

C-Bus Network Automation Controller

C-Bus Network Automation Controller

Item Number: 5500NAC

Product Dimensions

Width icon

Width93 mm

Height icon

Height108 mm

Depth icon

Depth63 mm

Datasheet

Specifications

Design

Market segment

buildings

Sustainable offer status

Green Premium product

Range

C-Bus

Product or component type

logic controller

Physical

Communication port protocol

  • C-Bus RJ45 (2000 devices)
  • BACnet IP RJ45 (500 devices)
  • Modbus RTU terminal block RS485 (31 devices)
  • IP (Internet Protocol) RJ45
  • serial link terminal block RS232
  • Modbus TCP RJ45

Power consumption in W

2 W

Local signalling

  • LED (green/red) for power
  • LED (green/red) for status indication
  • LED (green) for relay output (REL)
  • LED (multi-colour) for input status
  • LED (multi-colour) for RS232 link activity
  • LED (multi-colour) for serial link communication (RS485, RX, TX)
  • LED (green) for C-Bus status
  • LED (green/yellow) for Ethernet link

Control type

  • remote control
  • smartphone or tablet
  • RESET push-button
  • by touch panel
  • by web browser
  • RESET push-button cold restart
  • local control

Function available

  • visualisation
  • updateable software

Connections - terminals

  • power supply: screw terminal 3 cable(s) 1.5-1.5 mm²
  • LED lamp: screw terminal 2 cable(s) 1.5-1.5 mm²
  • relay digital output: screw terminal 3 cable(s) 1.5-1.5 mm²
  • digital input: screw terminal 2 cable(s) 1.5-1.5 mm²
  • RS232 link: screw terminal 3 cable(s) 1.5-1.5 mm²
  • RS485 link: screw terminal 5 cable(s) 1.5-1.5 mm²

Mounting support

DIN rail

Height

108 mm

Width

93 mm

Depth

63 mm

Ambient air temperature for operation

-5...45 °C

Relative humidity

10...90 %

IP degree of protection

IP20

Standards

  • AS/NZS CISPR 22
  • EN 55022 class A

REACh Regulation

Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

X

Environmental Disclosure

ENVPEP1701009EN

Circularity Profile

ENVEOLI1701009EN

Others

[Us] rated supply voltage

24 V DC

Port Ethernet

10BASE-T/100BASE-TX

Number of port

  • 1 USB 2.0 type A
  • 1 USB 1.1 type B
  • 1 RS232 (serial link)
  • 1 RS485 (Modbus)
  • 2 RJ45 (C-Bus)
  • 1 RJ45 (Ethernet)

Web services

web server

Web server

BMS controller compatible

Number of inputs

1 dry contact

Input impedance

  • 2.2 kOhm closed
  • 6.9 kOhm opened

Number of outputs

1 relay changeover

Output voltage

  • 24 V DC 1 A for relay
  • 48 V AC 1 A for relay

Total number of 18 mm modules

6

Operating altitude

<= 2000="">

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

0.34 kg

Package 1 Height

10 cm

Package 1 width

11.5 cm

Package 1 Length

16 cm

Unit Type of Package 2

PAL

Number of Units in Package 2

128

Package 2 Weight

43520.0 g

Package 2 Height

97.4 cm

Package 2 width

80 cm

Package 2 Length

60 cm

Unit Type of Package 3

CAR

Number of Units in Package 3

8

Package 3 Weight

2720.0 g

Package 3 Height

20.6 cm

Package 3 width

22.8 cm

Package 3 Length

33 cm

Product name

C-Bus Automation Controller
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Technical Leaflet

  • End of Life Manual

  • Product Environmental

  • Operating Manuals

  • System User Guide

  • Specifications

  • Application Solutions

  • Declaration of Conformity

  • Software - Archive

  • Software - Release

  • Firmware

Frequently Asked Questions

hide show

What’s new in the C-Bus Toolkit 1.16.0?

What’s new in the C-Bus Toolkit 1.16.0?
eDLT Firmware v1.6.0
The eDLT Firmware Updater has been updated to include firmware version 1.6.0. This incorporates support for eDLT units with the version 3 hardware.
When upgrading firmware on a unit with version 3 hardware, the updater must perform additional steps to complete the upgrade and so the upgrade process may take longer than it does for units with version 1 or 2 hardware.
A new option called Force font data installation has been added to the eDLT Firmware Updater. When selected, it will force the updater to always update the font data on the unit, even if it is already the same version. When unselected, the updater will skip the font data part of the upgrade if it is already known to be the same version as the new firmware being installed. By default, this option is not selected.

C-Bus – DALI-2 Gateway (5502CDGP230)
This release adds support for newer firmware revisions of the C-Bus – DALI-2 Gateway unit (5502CDGP230) when scanning networks.

SpaceLogic C-Bus Controllers
This release adds support for SpaceLogic C-Bus Network Automation Controller (5500NAC2) and SpaceLogic C-Bus Application Controller (5500AC2) units.

C-Gate 2.11.8
 

How do I access the Configurator and the Visualization webpage?

When accessing the embedded web server of the C-Bus Automation Controller (5500NAC/5500SHAC), the start page is displayed. From the start page, access the configurator and the following user modules:
  • PC/Tablet Visualization
  • Smartphone Visualization
  • Scheduler
  • Trends.
As administrator, configure the controller via the configurator and control user access to these four modules.

If the controller is set to directly access the Visualization bypass the start page, then the Configurator can be accessed using this URL.
https://192.168.254.10/scada-main

image.png

How many Administrator User Accounts can the C-Bus Automation Controller have?

The C-Bus Network Automation Controller (5500NAC) and the Wiser for C-Bus Automation Controller (5500SHAC), both Controllers can only have one administrator access.

Username: admin
Password: admin (by default, it can be changed)

Change the default password on the System page.
Path: Configurator → Utility tab → System button → System tab → Admin Access

image.png

How to set a timeout page on 5500NAC/SHAC Using javascript?

In NAC/SHAC > Scripting > edit custom JavaScripting

Copy and paste the code below

Modify adjust the timer value to your need (i.e 20000 = 20 sec)

Set the Current plantID to the page that you want it to time out too. For example high light in yellow showed on image below.

$(function() {

  

 // Back to Start after x seconds (in miliseconds)

 var SE_Timeout = 20000; // adjust this timer value if needed (20 seconds in miliseconds)

 var SE_Startpage = currentPlanId; // First page that is loaded

 var eventlist = 'vclick vmousedown vmouseout touchend';

  

 // Timer function no usage detected

 function No_Usage_Detected(callback, timeout, _this) {

  var timer;

  return function(e) {

    var _that = this;

    if (timer)

      clearTimeout(timer);

    timer = setTimeout(function() { 

      callback.call(_this || _that, e);

    }, timeout);

  }

 }

 

 

 

 // Back to start function when timer elapsed

  var SE_Goto_Startpage = No_Usage_Detected(function(e) {

  if ( currentPlanId != SE_Startpage ) {

  showPlan(SE_Startpage);

  }

 }, SE_Timeout);

  

 // Add event listener to document to detect user input

 $(document)

 .on(eventlist, function() {

  SE_Goto_Startpage();

 });

 

 // Add event listener to all iframes to detect user input inside iframes

 $('iframe').load(function() {

  var iframe = $('iframe').contents().find('html');

  iframe.on(eventlist, function(event) {

   SE_Goto_Startpage();

  });

 });

 

 

 

});


 

Are the backup files tar,gz interchangeable between the 5500NAC and the 5500SHAC?

A backup made on the NAC can be transferred to a SHAC and vise versa.

Considerations will need to be made in the circumstances where a SHAC limitation might be exceeded by a NAC project though (BACnet object limits, Modbus device limits, user account limits etc).

There are also options within the NAC/SHAC as well if the need to import or export sections of a project such as visualisations and scripts.

image.png
 

How to control RS-232 enabled devices with C-Bus Network Automation Controller – 5500NAC (5500SHAC)?

A Configuration Guide exist on the Exchange Community, see the link below or the attachment.

How to control RS-232 enabled devices with C-Bus Network Automation Controller – 5500NAC



 
Show More