c-bus ip66 infrascan learn

C-Bus Passive Infrared Occupancy Detectors, 110 Degree, IP66

Catalogue Number: 5750WPL
Colour Grey (GY)
  • Grey 1 PCE 1

Specifications

hide show
Range of product
  • Australian Series
  • C-Bus
    • Range
      C-Bus
      Product brand
      Clipsal
      Product or component type
      occupancy sensor
      Device application
      lighting
      Sensor type
      PIR
      Product specific application
      staircase monitoring
      [Ue] rated operational voltage
      15...36 V DC
      [In] rated current
      18 mA
      Communication network type
      C-Bus 100
      Number of channels
      1
      Type of setting
      light sensitivity adjustable
      Light intensity adjustment
      1-1 lux user selectable
      Data backed up
      non-volatile memory
      Local signalling
      LED for status
      Resolution
      1 s
      Starting time
      5 s
      Horizontal detection angle
      0-110 °
      Time delay range
      0...1 s (switch-on)
      Duty cycle
      1090 min
      Detection face
    • lateral: 12 m
    • frontal: 18 m
      • Connections - terminals
        2 flying leads
        Material
        plastic
        Device mounting
        surface
        Mounting support
      • wall
      • ceiling
        • Mounting height
          2.4 m
          Fixing center
          84 mm
          Width
          74 mm
          Height
          111 mm
          Depth
          138 mm
          IP degree of protection
          IP66
          Ambient air temperature for operation
          0-45 °C
          Unit Type of Package 1
          PCE
          Number of Units in Package 1
          1
          Package 1 Weight
          340 g
          Package 1 Height
          12.6 cm
          Package 1 width
          17.6 cm
          Package 1 Length
          24.8 cm
          EU RoHS Directive
          Compliant
          Mercury free
          Yes
          RoHS exemption information
          Yes
          China RoHS Regulation
          Product out of China RoHS scope. Substance declaration for your information
          Environmental Disclosure
          ENVPEP121002EN
          Circularity Profile
          ENVEOLI121002EN

          Documents & downloads

          hide show
          Filter items
          • All

          • Product Brochures

          • Technical Leaflet

          • End of Life Manual

          • Product Environmental

          • Software - Archive

          • Software - Release

          Frequently Asked Questions

          hide show

          What is the part code for a CBUS outdoor occupancy sensor

          The part code is 5750WPL

          Is the 750WPR Cbus compatible?

          No however the 5750WPL is the same sensor just cbus compatible

          Video: Program "Presence Detection" on C-Bus outdoor PIR sensor

          Video: Program "Presence Detection" on C-Bus outdoor PIR sensor

          Objective:
          Presence detection sets the sensor to trigger on motion. When motion is detected, the sensor sends a C-Bus command across C-Bus.
          this video will step through Program “Presence Detection”, it will cover those C-Bus sensors, 5751L, 5750WPL and 5753L with the old firmware v1.2.67.
          If having problem of programming Presence Detection please review FAQ “Program Presence Detection”

          Product Line:
          C-Bus Sensors: 5751L, 5750WPL and 5753L with the old firmware v1.2.67

          Environment:
          C-Bus Toolkit 1.15.5

          Resolution:
          • Open C-Bus Toolkit
          • Scan the Network
          • Double click the sensor to open its GUI
          • Select a control group from the “Key 4 Group” dropdown list, Presence Detection uses “Any Motion (AM)” function
          • Define the Expiry Time (5 minutes assigned by default) and click “OK”
          • Click “Apply” or “OK”
          • Save to Database and Physical Unit

          Top level --> Product category --> --> Building Automation and Control --> Building Management --> Building Management Systems --> C-Bus Automation system

          Video: Program "Absence Detection" on C-Bus outdoor PIR sensor

          Video: Program "Absence Detection" on C-Bus outdoor PIR sensor

          Objective:
          Absence detection sets the sensor to detect the absence of motion. If the lighting is on and the sensor detects the absence of motion, a timer is activated. When the timer expires and the sensor element still detects absence, a C-Bus command is sent to control lighting.
          This video will step through Program “Absence Detection”, it will cover those C-Bus sensors, 5751L, 5750WPL and 5753L with the old firmware v1.2.67.
          If having problem of programming Absence Dotation please review FAQ “Program Absence Detection”

          Product Line:
          C-Bus Sensors: 5751L, 5750WPL and 5753L with the old firmware v1.2.67

          Environment:
          C-Bus Toolkit 1.15.5

          Resolution:
          • Open C-Bus Toolkit
          • Scan the Network
          • Double click the sensor to open its GUI
          • Select a control group from the “Key 1 Group” dropdown list
          • Define the Expiry Time (5 minutes assigned by default) and click “OK”
          • Go to Key Functions tab and change the “On Key” on MD column for Short Press to “Idle”
          • A Confirm-21000 message will pop up
          • Click “YES” to accept the non-PIR functions
          • Click “Apply” or “OK”
          • Save to Database and Physical Unit
          Top level --> Product category --> --> Building Automation and Control --> Building Management --> Building Management Systems --> C-Bus Automation system

          Which outdoor sensors have a sensitivity adjustment

          The  part codes are  100SA360, 750WP and 750WPR

          Can 750WP be connected in parallel to control the same load .

          No. Need to use the 750WPR, three wire device when connecting in parallel
          For more information on the 750 series please visit the Clipsal web site on the link provided . https://www.clipsal.com/Trade/search-results?q=750w
          Show More