Smoke Alarm, Photoelectric, Surface Mount, 240V 9V D.C., Backup

Smoke Alarm, Photoelectric, Surface Mount, 240V 9V D.C., Backup

Smoke Alarm, Photoelectric, Surface Mount, 240V 9V D.C., Backup

Item Number: 755PSMA4

Datasheet

Specifications

Design

Sustainable offer status

Green Premium product

Range

Fire Tek

Product brand

Clipsal

Product or component type

smoke detector

Device application

early detection of smouldering fires and open fires

Physical

Supply

mains

Function available

  • local alarm
  • hush function
  • self-test of smoke detection

Control type

button (test/hush function)

Operating distance

  • 50 m indoor use line of sight
  • 140 m in free field

Local signalling

  • visual: 1 LED (red) for warning and low battery
  • visual: 1 LED (green) for ON status
  • sound: signal
  • sound: alarm

Connections - terminals

  • (line) - 2 x 1.5 mm²
  • (neutral) - 2 x 1.5 mm²
  • (earth loop) - 2 x 1.5 mm²
  • (interconnect) - 2 x 1.5 mm²

Type of installation

indoor

Device mounting

surface

Mounting support

  • ceiling
  • wall-mount

Fixing mode

by screws

Height

47 mm

Ambient air temperature for operation

0...45 °C

Relative humidity

5...95 %

Product certifications

  • RCM
  • SAI
  • Activfire

Standards

  • ISO 8201
  • AS 3786:2014
  • AS/NZS 60950.1
  • AS/NZS 60065

REACh Regulation

Free of Substances of Very High Concern above the threshold

REACh free of SVHC

Yes

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

X

Environmental Disclosure

ENVPEP1907002EN

Circularity Profile

ENVEOLI1907002EN

Quantity per set

set of 1

Type of packing

carton

Others

[Us] rated supply voltage

50 Hz

Backup type

battery

Battery life

1 year(s)

Output voltage limits

interconnection: 6.5...20 V

Type of alarms

low battery at 6.9...7.5 V

Detection type

smoke

Number of devices

40 for wired alarm

Response time

< 30="">

Noise level

85 dB at 3 m, minimum

Time delay range

  • 10 min (hush)
  • 10 h (do not disturb)

Diameter

140 mm

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

331.0 g

Package 1 Height

5.3 cm

Package 1 width

14.5 cm

Package 1 Length

14.5 cm

Electronic sensor type

photo-electric sensor
Show all specifications

Frequently Asked Questions

hide show

Can 755PSMA, 755SMA , 755PSMA2 and 755PSMA4 be interlinked together?

Yes they can all be interlinked together.
Interconnecting smoke alarms is a method of joining a series of alarms so that if any one alarm senses smoke, all the connected alarms will operate (alarm). 
A 9 V signal is applied to the interconnect wire (referenced to neutral) to alarm all the other interconnected alarms.
• All interconnected smoke alarms must be supplied from the same circuit.
• A common Neutral must be used for the Interconnect to operate.
• DO NOT connect the Interconnect wire to Active or Neutral.
• A maximum of 40 Clipsal 755 smoke alarms can be installed on one circuit (wired interconnection only).
• Only Clipsal smoke alarms can be interconnected with each other.
Failure to follow these instructions may result in injury and equipment damage / malfunction.

Click on link for further information on smoke alarms:https://www.clipsal.com/search?q=SMOKE%20ALARMS

What is the warranty period for the 755 series smoke alarms?

The 755 series smoke alarms have a 5 year warranty period
 

Why does my smoke alarm randomly keep going off, and how to stop it?

This is mainly due to something setting it off ie. Dust partials, dust mites, bugs, dirt. To avoid this it is recommended to clean your s/a every month, the best way to do this is by getting a long nose vacuum and vacuum the outside of the alarm trying to get in all the gaps. *NOTE DO NOT OPEN ALARM AND DO THIS AS IT MAY DAMAGE THE ALARM. Spray bug repellent on a cloth and wipe the ceiling around the smoke alarm to act as a future bug deterrent. Test the smoke alarm after cleaning.
Refer also to maintenance and Trouble shooting Guide in link below:
https://download.schneider-electric.com/files?p_Doc_Ref=Smoke_Alarm_Maintenance_Guide&p_File_Ext=.PDF
755PSMA4

Are the 755PSMA4 & 755RLPSMA4 compliant with the AS3786:2014+A12015?

Yes they are both compliant with AS3786:2014+A12015
See link below for Certificate of Conformity:
https://download.schneider-electric.com/files?p_Doc_Ref=CA_CSIRO_AFP-3140_ActiFire&p_File_Ext=.PDF

Is there a device that turns my lights on when my smoke alarm goes on?

Yes, if you have a 755PSMA4, you can use the 755RB Base which has a set of built in contacts or you can use a 756 Isolation unit which also carries out the same task.
 
755PSMA4
image.png

Please go to the website via the following links below and check under the Documentation Tab for more information.

Australia - https://www.clipsal.com/products/detail?CatNo=755PSMA4&itemno=755PSMA4&backto=/search?q=psma4&tab-document-1=0
New Zealand - https://www.pdl.co.nz/products/detail?CatNo=755PSMA4&itemno=755PSMA4&backto=/search?q=755PSMA4&tab-document-1=0#
 
755RB
image.png


Please go to the website via the following links below and check under the Documentation Tab for more information.

Australia - https://www.clipsal.com/products/detail?CatNo=755RB&itemno=755RB&backto=/search?q=755RB&tab-document-1=0
New Zealand - https://www.pdl.co.nz/products/detail?CatNo=755RB&itemno=755RB&backto=/search?q=755RB&tab-document-1=0

What causes the smoke alarm to continuously beep ?

The dust inside the smoke alarms can cause a continuous beep.
Please follow the regular maintenance check to avoid this.

Vacuum the smoke alarms using a soft brush attachment-
Keeping your smoke alarm free of dust particles, dirt, kitchen grease or cobwebs will help you reduce false alarms and ensure any smoke can easily reach the internal sensing chamber.

Clean and wipe down around unit-
Clean around the smoke alarm unit and remove any insects or other contamination which may have occurred. Spray bug repellent on a cloth and wipe the ceiling around the smoke alarm to act as a future bug deterrent. Clean every 3-6 months to mitigate insect ingress.

ALWAYS TEST THE SMOKE ALARM AFTER CLEANING.

Attached is the Clipsal smoke alarm troubleshooting guide for more info.

Clipsal Smoke Alarms.png
 
Show More