Smoke Alarm Mount Base Integrated, 2A, Relay and Remote Test

Smoke Alarm Mount Base Integrated, 2A, Relay and Remote Test

Smoke Alarm Mount Base Integrated, 2A, Relay and Remote Test

Item Number: 755RB

Datasheet

Home owner checking their fire alarm
PDL Firetek group shot of products and packaging
dimensions

Specifications

Design

Product brand

Clipsal

Sustainable offer status

Green Premium product

Physical

REACh Regulation

Free of Substances of Very High Concern above the threshold

REACh free of SVHC

Yes

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

X

Environmental Disclosure

ENVPEP1907002EN

Circularity Profile

ENVEOLI1907002EN

Others

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

165.0 g

Package 1 Height

3.5 cm

Package 1 width

15.0 cm

Package 1 Length

14.5 cm
Show all specifications

Frequently Asked Questions

hide show

What size relay is in the 755RB?

The 755RB has a 2A relay.

Some of the key features are:
  • Integral 2A Isolated voltage free changeover relay
  • Control/activate third party devices (i.e. lighting, security, or home automation systems)
  • Dry contact input for remote test/hush functions from a momentary switch
  • Suitable for use with 755PSMA2 and 755RLPSMA2 smoke alarms
image.png
 
Please go to the following links below and check under the Documentation Tab for more information.

Australia - https://www.clipsal.com/products/detail?CatNo=755RB&itemno=755RB&backto=/search?q=755RB&tab-document-1=0
New Zealand - https://www.pdl.co.nz/products/detail?CatNo=755RB&itemno=755RB&backto=/search?q=755RB&tab-document-1=0

What is the warranty period for the 755 series smoke alarms?

The 755 series smoke alarms have a 5 year warranty period
 

What is the function of the local/global switch on 755PSMA2 and 755RLPSMA2?

GLOBAL / LOCAL RELAY SETTING
Both the 755PSMA2 and 755RLPSMA2 smoke alarms have a ‘Global / Local’ switch located on them (see the diagram below). This switch is only used for operation with the 755RB
relay mounting base.
• When the ‘Global / Local’ switch is set to ‘Local’, only activation of the physically connected alarm will cause the relay to operate.
• When the ‘Global / Local’ switch is set to ‘Global’, activation of any smoke alarm that is interconnected with the base causes the relay to operate.
• The default setting is ‘Global’.
For further information, please visit:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=755PSMA2
https://www.clipsal.com/Trade/Products/ProductDetail?catno=755RLPSMA2
https://www.clipsal.com/Trade/Products/ProductDetail?catno=755RB

 

Is there a device that turns my lights on when my smoke alarm goes on?

Yes, if you have a 755PSMA4, you can use the 755RB Base which has a set of built in contacts or you can use a 756 Isolation unit which also carries out the same task.
 
755PSMA4
image.png

Please go to the website via the following links below and check under the Documentation Tab for more information.

Australia - https://www.clipsal.com/products/detail?CatNo=755PSMA4&itemno=755PSMA4&backto=/search?q=psma4&tab-document-1=0
New Zealand - https://www.pdl.co.nz/products/detail?CatNo=755PSMA4&itemno=755PSMA4&backto=/search?q=755PSMA4&tab-document-1=0#
 
755RB
image.png


Please go to the website via the following links below and check under the Documentation Tab for more information.

Australia - https://www.clipsal.com/products/detail?CatNo=755RB&itemno=755RB&backto=/search?q=755RB&tab-document-1=0
New Zealand - https://www.pdl.co.nz/products/detail?CatNo=755RB&itemno=755RB&backto=/search?q=755RB&tab-document-1=0

What is the voltage rating of the 755RB contacts?

The relay contacts have a rating of 2A at 250VAC
Firetek group shot

Range

PDL Fire Tek range helps protect the most valuable assets; family, friends and the home.

They are backed by the SAI Global 5 ticks certification of quality, offering robust designs for reliability, ensuring early detection and warning from hazardous smoke and fire.

The Australian Building Code mandates all new homes must have AS3786:2014 compliant smoke alarms installed, interconnected and hard wired to mains power.

By having Fire Tek's smoke alarms installed, you will have the best chance of escaping the devastating effects of a house fire