Smoke Alarm Mount Base Integrated, 2A, Relay and Remote Test

Smoke Alarm Mount Base Integrated, 2A, Relay and Remote Test

Smoke Alarm Mount Base Integrated, 2A, Relay and Remote Test

Item Number: 755RB

Datasheet

Specifications

Design

Sustainable offer status

Green Premium product

Product brand

Clipsal

Physical

REACh Regulation

Free of Substances of Very High Concern above the threshold

REACh free of SVHC

Yes

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

X

Environmental Disclosure

ENVPEP1907002EN

Circularity Profile

ENVEOLI1907002EN

Others

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

165.0 g

Package 1 Height

3.5 cm

Package 1 width

15 cm

Package 1 Length

14.5 cm
Show all specifications

Frequently Asked Questions

hide show

What size relay is in the 755RB?

The 755RB has a 2A relay.

Some of the key features are:
  • Integral 2A Isolated voltage free changeover relay
  • Control/activate third party devices (i.e. lighting, security, or home automation systems)
  • Dry contact input for remote test/hush functions from a momentary switch
  • Suitable for use with 755PSMA2 and 755RLPSMA2 smoke alarms
image.png
 
Please go to the following links below and check under the Documentation Tab for more information.

Australia - https://www.clipsal.com/products/detail?CatNo=755RB&itemno=755RB&backto=/search?q=755RB&tab-document-1=0
New Zealand - https://www.pdl.co.nz/products/detail?CatNo=755RB&itemno=755RB&backto=/search?q=755RB&tab-document-1=0

What is the warranty period for the 755 series smoke alarms?

The 755 series smoke alarms have a 5 year warranty period
 

What is the function of the local/global switch on 755PSMA2 and 755RLPSMA2?

GLOBAL / LOCAL RELAY SETTING
Both the 755PSMA2 and 755RLPSMA2 smoke alarms have a ‘Global / Local’ switch located on them (see the diagram below). This switch is only used for operation with the 755RB
relay mounting base.
• When the ‘Global / Local’ switch is set to ‘Local’, only activation of the physically connected alarm will cause the relay to operate.
• When the ‘Global / Local’ switch is set to ‘Global’, activation of any smoke alarm that is interconnected with the base causes the relay to operate.
• The default setting is ‘Global’.
For further information, please visit:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=755PSMA2
https://www.clipsal.com/Trade/Products/ProductDetail?catno=755RLPSMA2
https://www.clipsal.com/Trade/Products/ProductDetail?catno=755RB

 

Is there a device that turns my lights on when my smoke alarm goes on?

Yes, if you have a 755PSMA4, you can use the 755RB Base which has a set of built in contacts or you can use a 756 Isolation unit which also carries out the same task.
 
755PSMA4
image.png

Please go to the website via the following links below and check under the Documentation Tab for more information.

Australia - https://www.clipsal.com/products/detail?CatNo=755PSMA4&itemno=755PSMA4&backto=/search?q=psma4&tab-document-1=0
New Zealand - https://www.pdl.co.nz/products/detail?CatNo=755PSMA4&itemno=755PSMA4&backto=/search?q=755PSMA4&tab-document-1=0#
 
755RB
image.png


Please go to the website via the following links below and check under the Documentation Tab for more information.

Australia - https://www.clipsal.com/products/detail?CatNo=755RB&itemno=755RB&backto=/search?q=755RB&tab-document-1=0
New Zealand - https://www.pdl.co.nz/products/detail?CatNo=755RB&itemno=755RB&backto=/search?q=755RB&tab-document-1=0

Can the Clipsal 755PFM4 have a remote switch fitted for test/Hush function?

No, the 755PFM4 is a flush mount smoke alarm that can not be fitted with a remote Test/Hush button.
To achieve the remote Test/Hush function you will need a surface mount alarm such as the 755LPSMA4 or 755RLPSMA4 in conjunction with the 755RB relay base.

What is the voltage rating of the 755RB contacts?

The relay contacts have a rating of 2A at 250VAC