Ceiling Rose - terminal

White Electric | Ceiling Rose - terminal

Ceiling Rose - terminal

Item Number: 93-WE

Datasheet

Specifications

Design

Product brand

Clipsal

Product or component type

ceiling rose

Colour tint

white

Physical

[Ue] rated operational voltage

500 V

Rated current

15 A

Fixing mode

by screws

EU RoHS Directive

Under investigation

Provided equipment

  • cover
  • base
    • Others

      Unit Type of Package 1

      PCE

      Number of Units in Package 1

      1

      Package 1 Weight

      64 g

      Package 1 Height

      3.6 cm

      Package 1 width

      6.4 cm

      Package 1 Length

      6.5 cm
      Show all specifications

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      Frequently Asked Questions

      hide show

      Can a VFD run a wound-rotor motor?

      Issue:
      Wound-rotor motor

      Product Line:
      Altivar drives

      Environment:
      All models and serial numbers

      Cause:
      None

      Resolution:
      Altivar variable frequency drives may be used to operate wound-rotor motors. 
      Most wound-rotor motors are used where high starting torque is required so the Altivar 312, Altivar 32, Altivar 71 (obsolete) or the currently available Altivar 320, Altivar 340, or Atlivar 930 (sized for Heavy Duty) drive would be most suitable for this application. 
      The wound-rotor motors use resistor to connect the rotor windings.  The resistance can be adjusted to control the speed/torque characteristics of the motor. 
      To use a variable frequency drive with a wound-rotor motor the resistors would need to be shorted.  It is not appropriate to switch the resistance when operating on a VFD.
      It is also recommended to use a dv/dt filter on the output of the drive to smooth the PWM.

      Is it possible to reset the Total Energy on iEM3255 ?

      Total Energy cannot be reset on iEM3255.

      iem3255.png

      It is possible to reset all measurements except total active energy and total reactive energy.
      Refer to the attached user manual.

      The short video shows how to reset Partial Active Energy on the Acti 9 iEM3255 kWh Meter.

       

      What is the difference between a removable locking device and a fixed locking device for the Compact NS and NSX 100 to 630 range.

      The removable locking device enables the MCCB to be locked in the OFF position only and is removable from the device.
      29370 Removable Lock device
      The fixed locking device enables the MCCB to be locked in the OFF or ON position but is fixed to the device.
      LV429371 Fixed Locking device 100..250A LV432631 Fixed  Locking device above 630A

      What does the cable marked V90 stand for on a Clipsal 800CL

      The V90 marking means that the cable is rated to an operation temperature of 90°C.

      For further information please visit https://www.clipsal.com/products/detail?CatNo=800CL&tab-document-1=0

      cord set 32a cooker lead

      What is the IP Rating for the motion sensor 753R?

      The IP Rating for the sensor 753R is IP20.
      Some of its key features are:
      • 10A maximum load current
      • Stand-by power consumption is less than 1W
      • 3 Wire
      • Neutral required
      • 30 seconds warmup time
      • 360°, circular detection field 14m diameter rated detection field at maximum sensitivity
      • 5 seconds to 20 minutes timer delay range
      • Cables accommodates 4 terminals, up to 2 x 2.5mm² cable per terminal
      • Length of sensor 141.5mm
      • 72mm Diameter
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=753R
       

       

      What is the alternative to the MG NS400N MCCB, 32693?

      The NS400N equivalent is  LV432403 (NAX400N frame) + LV432081 (trip unit).

      LV432403
      image.png
      Please go to the following links below and check under the Documentation Tab for more information.

      Australia - https://www.se.com/au/en/product/LV432403/circuit-breaker-basic-frame%2C-compact-nsx400n%2C-50-ka-at-415-vac-50-60-hz%2C-400-a%2C-without-trip-unit%2C-3-poles/

      New Zealand - https://www.se.com/nz/en/product/LV432403/circuit-breaker-basic-frame%2C-compact-nsx400n%2C-50-ka-at-415-vac-50-60-hz%2C-400-a%2C-without-trip-unit%2C-3-poles/

      LV432081
      image.png
      Please go to the following links below and check under the Documentation Tab for more information.

      Australia - https://www.se.com/au/en/product/LV432081/trip-unit-micrologic-2.3-for-compact-nsx-400-630-circuit-breakers%2C-electronic%2C-rating-400a%2C-3-poles-3d/

      New Zealand -  https://www.se.com/nz/en/product/LV432081/trip-unit-micrologic-2.3-for-compact-nsx-400-630-circuit-breakers%2C-electronic%2C-rating-400a%2C-3-poles-3d/
      Show More