Arc Fault Detection Circuit Breaker iDPN N Arc, 1P+N 10A C 6000A

Arc Fault Detection Circuit Breaker iDPN N Arc, 1P+N 10A C 6000A

Arc Fault Detection Circuit Breaker iDPN N Arc, 1P+N 10A C 6000A

Item Number: A9FDB610

Product Dimensions

Width icon

Width36 mm

Height icon

Height81 mm

Depth icon

Depth72 mm

Datasheet

Specifications

Design

Range of product

Acti 9

Range

Acti 9

Product or component type

arc fault detection circuit breaker

Sustainable offer status

Green Premium product

Physical

Standards

  • IEC 60898-1
  • EN/IEC 62606
    • [In] rated current

      10 A at 30 °C

      [Ue] rated operational voltage

    • 230 V AC 50 Hz conforming to IEC 62606
    • 230 V AC 50 Hz conforming to EN/IEC 60898-1
      • Control type

        toggle

        Local signalling

        ON, OFF, fault trip

        Mounting mode

        clip-on

        Mounting support

        DIN rail

        Mechanical durability

        20000 cycles

        Electrical durability

        20000 cycles 230 V AC 50 Hz

        Cable entry

        top

        Connections - terminals

      • tunnel type terminal for 1 cable(s) 10-10 mm² flexible
      • tunnel type terminal for 2 cable(s) 2.5-2.5 mm² flexible
      • tunnel type terminal for 1 cable(s) 16-16 mm² rigid
      • tunnel type terminal for 2 cable(s) 2.5-2.5 mm² rigid
        • Wire stripping length

          14 mm

          Height

          81 mm

          Width

          36 mm

          Depth

          72 mm

          Net weight

          190 g

          IP degree of protection

          IP20

          Ambient air temperature for operation

          -25-60 °C

          Ambient air temperature for storage

          -40-85 °C

          Product certifications

          RCM

          REACh Regulation

          Free of Substances of Very High Concern above the threshold

          EU RoHS Directive

          Compliant

          Mercury free

          Yes

          RoHS exemption information

          Yes

          China RoHS Regulation

          Product out of China RoHS scope. Substance declaration for your information

          Environmental Disclosure

          ENVPEP1312033EN

          Circularity Profile

          ENVEOLI1312033EN

          Others

          Circuit breaker application

          distribution

          Product name

          Acti 9 iDPN N Arc

          Product specific application

          fire prevention by arc detection

          Device short name

          iDPN N Arc

          Poles description

          1P + N

          Curve code

          C

          Breaking capacity

          6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 60898-1

          Network type

          AC

          Neutral position

          left

          Trip unit technology

          thermal-magnetic

          Number of protected poles

          1

          Network frequency

          50 Hz

          Device location in system

          outgoer

          Magnetic tripping limit

          5...10 x In

          Limitation class

          3 conforming to IEC 60898-1

          Threshold tripping voltage

          400 V for 200 ms

          [Uimp] rated impulse withstand voltage

          4 kV conforming to IEC 60898-1

          [Ui] rated insulation voltage

          400 V AC

          Contact position indicator

          yes

          Overvoltage category

          III

          Tightening torque

          2-2 N.m

          Comb busbar and distribution block compatibility

        • ProDis
        • Librio
          • Connection pitch

            9 mm pitches

            4

            Heat dissipation

            2.6-2.6 W at 230 V - 10 A

            Pollution degree

            2

            Tropicalisation

            severity B conforming to IEC 60068-2-30 for 28 d

            Operating altitude

            2000 m

            Package 1 Weight

            0.128 kg

            Package 1 Height

            0.86 dm

            Package 1 width

            0.4 dm

            Package 1 Length

            1 dm

            WEEE

            The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
            Show all specifications

            Documents & downloads

            hide show
            Filter items
            • All

            • Installation Instruction

            • Product Environmental

            • Certificates (MSDS)

            Frequently Asked Questions

            hide show

            What are the codes for the Fault Arc Detection Devices?

            The part numbers for the Fault Arc Detection Devices are as follows.
            6A - A9FDB606
            10A - A9FDB610
            16A - A9FDB616
            20A - A9FDB620
            25A - A9FDB625

            What is the difference between A9D32620 and A9D33620 RCBO Acti 9 devices?

             
             

            A9D33620 = SI (Super Immunised)
            A9D32620 = Type A (AC or pulsating DC)

            Type A RCBO = Tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising.
            Type Si RCBO = With all the features of a Type A device, “Si” type Super Immunised earth leakage protection range has been specially developed to be used with loads or in environments causing disturbances. Examples are lightning or switching surges, harmonics generated by increasing number of loads and constant load leakage current from electronic ballasts, speed drives, computers, etc. The Si increases safety and allows improved continuity of supply.
             

            What is the alternative for 19772 ?

            The A9D32610 is the alternative for the 19772.

            Please see this link for more information:
            https://www.schneider-electric.co.nz/en/product/A9D32610/acti-9-idpn-n-vigi---rcbo---1p%2Bn---10a---c-curve---6000a---30ma---type-a/