DPN Vigi Domae B 16A 1PN 4,5kA 30mA A; residual current circuit breaker

DOMAE - earth leakage circuit breaker - 1P+N - C - 10A - 30mA - 6000A - A

Catalogue Number: DOM19802
DPN Vigi Domae B 16A 1PN 4,5kA 30mA A; residual current circuit breaker
Colour:
Colour: Per UOM Std.
  • 1 PCE 1

Specifications

hide show
Device application
distribution
Range
Domae
Range of product
Domae
Product or component type
residual current breaker with overcurrent protection (RCBO)
Poles description
1P + N
Neutral position
left
Earth-leakage protection class
type A
Suitability for isolation
yes
[In] rated current
10 A
Network type
AC
Network frequency
50 Hz
[Ue] rated operational voltage
230 V AC 50 Hz conforming to IEC 61009-1
Trip unit technology
thermal-magnetic
Curve code
C
Magnetic tripping limit
5...10 x In
Earth-leakage sensitivity
30 mA
Earth-leakage protection time delay
instantaneous
Breaking capacity
6000 A Icn at 230 V AC 50 Hz conforming to IEC 61009-1
Electrical insulation class
class II
Rated breaking and making capacity
Idm 4500 A at 230 V AC 50 Hz conforming to IEC 61009-1
Limitation class
3
[Ui] rated insulation voltage
400 V AC 50 Hz
Contact position indicator
yes
Control type
toggle
Local signalling
ON/OFF indication
Mounting support
rail
9 mm pitches
4
Height
81 mm
Width
36 mm
Depth
72 mm
Net weight
0.125 kg
Mechanical durability
20000 cycles
Electrical durability
20000 cycles 230 V AC 50 Hz conforming to IEC 61009-1
Connections - terminals
  • tunnel type terminals1-10 mm² flexible
  • tunnel type terminals1-16 mm² rigid
    • Wire stripping length
      15 mm
      Tightening torque
    • 3.5-3.5 N.m upstream
    • 3.5-3.5 N.m downstream
      • Earth-leakage protection
        with
        Standards
      • IEC 61009-1
      • AS/NZS 61009.1
        • IP degree of protection
          IP20 conforming to IEC 60529
          Ambient air temperature for operation
          -5-60 °C
          Ambient air temperature for storage
          -40-60 °C
          Sustainable offer status
          Green Premium product
          REACh Regulation
          Free of Substances of Very High Concern above the threshold
          EU RoHS Directive
          Compliant
          Mercury free
          Yes
          RoHS exemption information
          Yes
          China RoHS Regulation
          Product out of China RoHS scope. Substance declaration for your information
          Environmental Disclosure
          ENVPEP100503EN
          Circularity Profile
          N/A

          Documents & downloads

          hide show
          Filter items
          • All

          • CAD Files and Packs

          • Technical Data Catalogues

          • Installation Instruction

          Frequently Asked Questions

          hide show

          Is the DOM19805 top or bottom fed

          This product is a top or bottom fed

          What is the maximum number of units that can be assembled on an XVP beacon tower?

          It is possible to stack a combination of up to 5 illuminated and audible units (one audible unit maximum) to create an XVP beacon tower. 

          Example 1: 5 illuminated lens units 
          Example 2: 4 illuminated lens units + 1 audible signaling unit

          BMXP3420302/102 V2.2 PV02 are not operational

          Goals and Symptoms

          CPU BMXP3420302/102 V2.2 PV02 from DOM 1030 to DOM1042 are not operational when they are new : CANopen status green led is flashing, you cannot load an application inside with CANopen master configured nor RUN the CPU.
          Les processeurs BMXP3420302/102 V2.2 PV02, depuis DOM 1030 jusque DOM1042, sont en défaut quand ils sont nouveaux: la led CANopen verte clignote et vous ne pouvez pas télécharger une application configurée avec le maitre CANopen, ni mettre en RUN le processeur

          Causes and Fixes

          To recover a normal behavior, you have to upgrade to firmware version V2.2 using UnityLoader, even if your current CPU is already in firmware version V2.2.
          You'll find this firmware version on Pl@net or on www.schneider-electric.com web site, or even attached to that current resolution as well as a document that explains how to deal with UnityLoader and firwmare upgrade on M340 range.

          We advise to respect the following procedure to avoid any problem during firmware update (otherwise you may have an error message when writing the Flash memory)
          1) Remove SDcard from CPU before power on M340 CPU
          2) Then power on M340 CPU.
          3) Once CPU is running, you can insert SDcard in CPU slot
          4) Finally perform normal firmware upgrade thanks to UnityLoader.

          Pour retrouver un comportement normal, vous devez télécharger de nouveau une version V2.2 en utilisant l'outil UnityLoader, même si votre processeur actuel est déjà dans la version V2.2.
          Vous trouverez cette version sur Pl@net ou sur le site Web www.schneider-electric.com.
          Par commodité, attachés à cette résolution vous trouverez aussi les informations nécessaires au téléchargement:

          • un document qui explique comment réaliser le téléchargement avec UnityLoader
          • les 2 fichiers correspondants aux deux processeurs concernés. Choisissez celui qui est approprié à votre cas.

          Nous conseillons de respecter la procédure suivante pour assurer un téléchargement sans risque (autrement vous pourriez avoir une message d'erreur lors de l'écriture sur le méloire Flash).
          1) Enlever la SDCARD du processeur avant de mettre sous tension ce processeur.
          2) Mettre sous tension le processeur.
          3) Une fois que le processeur est opératoire, ré-insérer la SCCARD dans son emplacement.
          4) Exécutez le téléchargement de la version V2.2 avec l'outil UnityLoader

          M340_upgrade_procedure.pdf BMXP3420102_V220.ldx BMXP3420302_V220.ldx

          Legacy KB System (APS) Data: RESL203659 V3.0, Originally authored by FlLa on 10/07/2010, Last Edited by FlLa on 11/05/2010
          Related ranges: Modicon M340