EcoStruxure EV Charging Expert EV charge controller 250 charging stations, 20 zones, dynamic load management
Item Number: HMIBX1A0NEVB100SCP
Specifications
Design
| Range | EcoStruxure EV Charging Expert |
|---|---|
| Product or component type | EV charge controller |
| Device application | to manage the overall energy allocated to each vehicle |
Physical
| Type of installation | indoor |
|---|---|
| Range compatibility |
|
| Mounting mode | wall mount |
| Mounting support | DIN rail |
| Mounting position | horizontal/vertical |
| Load type | 250 charge points |
| Function available |
|
| Power consumption in w | 24 W |
| Height | 141 mm |
| Width | 99 mm |
| Depth | 48 mm |
| Net weight | 950 g |
| Standards |
|
| Product certifications |
|
| Ip degree of protection | IP20 |
| Ambient air temperature for operation | -20...70 °C |
| Ambient air temperature for storage | -40...80 °C |
| Relative humidity | 10...95 % |
| Mercury free | Yes |
| Rohs exemption information | Yes |
| Environmental disclosure | ENVPEP2405013EN |
| Eu rohs directive | Compliant By Exemption |
Documents & downloads
-
All
-
How to video
-
Product Brochures
-
CAD Files and Packs
-
Environmental Disclosure
-
End of Life Manual
-
Operating Manuals
-
System User Guide
-
Technical illustration
-
Application Notes
-
Declaration of Conformity
-
Declaration of Conformity (Sustainability)
-
Firmware
Frequently Asked Questions
How can the correct communication port be identified for EVlink chargers, and where can the configured port be verified?
Hide ShowProduct Line: EVlink EV Charging Equipment (EVCE)
Environment: EVlink chargers commissioned with OCPP communication profiles
Resolution: The recommended communication profile is Security Profile 2 (port 9982). However, the communication profile is automatically configured by the EVCE during charger commissioning, so no manual action is required from the customer.
Available communication ports:
- WS (not recommended): 9979
- WSS Security Profile 0: 9980
- WSS Security Profile 1: 9981
- WSS Security Profile 2 (recommended): 9982
Verification: If verification is required, the customer can use eSetup or ECCT and review the Supervision Configuration. The configured port indicates which Security Profile is currently in use.
**Important Note: Do not manually modify the configured port. The EVCE stores the selected communication profile and validates it during operation.
EV Charging Expert – Firmware Migration Blocked Due to Faulty or Invalid Connected Charger
Hide Show
Issue: EV Charging Expert (Load Management System) is unable to proceed with firmware migration if any connected charger is in a faulty, charging, or disconnected state.
Product Line: EcoStruxure EV Charging Expert
Environment: HMIBX1A0NEVB100SCP, HMIBSCEA53D1EM30
Resolution:
The firmware migration process in EV Charging Expert requires all connected EV chargers to be in a valid and healthy state.
If even one charger connected to the system is:
- In error state
- Actively charging
- Disconnected or not communicating properly
…the firmware migration will be blocked, and the customer may encounter this error during the upgrade process where the Migrate button will be greyed out.
Corrective Actions:
- Verify that all connected chargers are online and communicating correctly.
- Ensure no charger is actively charging during the migration.
- Resolve any existing faults or error states on all chargers.
- Confirm all chargers are in a ready / idle state before retrying the firmware migration.
Once the issue is resolved, the migration button will become available (enabled) again, allowing you to proceed with the firmware migration.