Datasheet
Specifications
Design
Product brand
Product or component type
Colour tint
Sustainable offer status
Physical
Provided equipment
Device mounting
[ue] rated operational voltage
Rated current
Reach regulation
Eu rohs directive
Toxic heavy metal free
Mercury free
Rohs exemption information
China rohs regulation
Environmental disclosure
Circularity profile
Others
Package 1 bare product quantity
Unit type of package 1
Number of units in package 1
Package 1 height
Package 1 width
Package 1 length
Package 1 weight
Documents & downloads
hide show-
All
-
Declaration of Conformity
-
Certificates (MSDS)
Frequently Asked Questions
hide showCan new accessories be used on older style contactors
Product Line:
IEC contactors and starters
Environment:
Pre-Tesys Contactors
Cause:
Identifying product compatibility
Resolution:
Yes, all front mount D2 and Tesys series auxiliary modules are backward forward compatible.
Auxiliary contact modules for the LC1D and LC2D contactors
Product Line:
Contactor and Starters - IEC
Environment:
North American Products
Resolution:
Select based on application requirements. Please note that the TeSys and Pre-TeSys auxiliary blocks are backward/forward compatible.
Front Mounting; maximum of 1 block per contactor:
N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
--1-----------1---------LADN11-----------LA1DN11
--1-----------1---------LADN11G---------LA1DN11G (See Footnote 1)
--1-----------1---------LADN11P---------LA1DN11P (See Footnote 1)
--2-----------0---------LADN20-----------LA1DN20
--2-----------0---------LA1DX20---------LA1DX20 (See Footnote 2)
--2-----------0---------LA1DY20---------LA1DY20 (See Footnote 3)
--0-----------2---------LADN02-----------LA1DN02
--2-----------2---------LADN22-----------LA1DN22
--2-----------2---------LADN22G---------LA1DN22G (See Footnote 1)
--2-----------2---------LADN22P---------LA1DN22P (See Footnote 1)
--2-----------2---------LADC22------------LA1DC22 (See Footnote 4)
--3-----------1---------LADN31------------LA1DN31
--3-----------1---------LA1DZ31----------LA1DZ31 (See Footnote 5)
--1-----------3---------LADN13------------LA1DN13
--4-----------0---------LADN40------------LA1DN40
--4-----------0---------LA1DZ40-----------LA1DZ40 (See Footnote 6)
--0-----------4---------LADN04------------LA1DN04
Front Mounting; maximum of 1 block per contactor: For use with D2 Series 25 amp through 80 amp contactors and TeSys Series 40 amp through 80 amp only.
N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
--1-----------0--------LADN10----------LA1DN10
--0-----------1--------LADN01----------LA1DN01
Side Mounting; maximum of 1 block on each side for D2 Series and Tesys Series 40 through 80 amp contactors. Tesys 9 through 32, 115, and 150 amps contactors will accept 1 block and is limited to left side only. (*) DC control devices will not accept side mount auxiliaries.
(*) DC control exceptions that will accept one left side mounted auxiliary: LC1D115 & LC1D150.
N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
--1-----------1--------LAD8N11----------LA8DN11
--2-----------0--------LAD8N20----------LA8DN20
--0-----------2--------LAD8N02----------N/A
Footnotes:
{1.EN_US} EN50 012 Machine Tool Terminal Markings
{2.EN_US} (2) NO Sealed Dust Tight Contacts
{3.EN_US} Gold Flash Contacts
{4.EN_US} (1) NO & (1) NC Standard and (1) NO & (1) NC Make Before Break
{5.EN_US} (2) NO Dust Tight Contacts & (1) NO & (1) NC Standard Contacts
{6.EN_US} (2) NO Dust Tight Contacts & (2) NO Standard Contacts
Start an ATV312 using Modbus
Product Line:
Variable Frequency Drives
Environment:
Applies to ATV312
Cause:
Customer is not able to start the drive using Modbus.
Resolution:
Suggested to follow the status chart and send the values to the command word in sequence Hex 6 then 7 then F to Address 8501 (assuming there is no offset)
Are the 8501KPD12V63 devices equipped with form C contacts?
Product Line:
General Purpose Relays, 8501 Type K
Environment:
Relays and Timers
Resolution:
Change over is a European term for a Form C or single pole double throw contact.
Consider Digest 178 page 21-4 table 21.6.
Issue:
ILF fault on the ATV71 with an VW3A3501 CIC card installed.
Product line:
Altivar ATV71
Environment:
All models, all serial numbers
Cause:
If the CIC card is missing the external +24vdc pwr supply the drive will trigger an ILF fault after 1 sec of being powered up.
Resolution:
Per the CIC installation manual document, atv71_controller_inside_EN_V3 page 10, it is recommended to add an external power supply part number ABL7RE2402 to the controller inside cards +24vdc and com terminals to resolve issue.
If you are after a replacement electronic switch for a 5012S164/4L-WE then order the standard item “B5034MNLPCB-WE” which contains a PCB Assy plus the Rear Cover.
If you are after an equivalent to a 5012S164/4L-WE the closest we have can be achieved by ordering 1 x “B12/30/6-WE” + 3 x “5031NMML” + 9 x “5031NMS”
If just for replacement then you could get B503xNL and remove the Metal Plate and just use the gang switch to replace the old unit.
B5031NL, B5032NL, B5034NL