iDPN N Arc 1P-N 6A...25A C 6000A Arc fault detection circuit breaker

Arc Fault Detection Circuit Breaker iDPN N Arc, 1P+N 16A C 6000A

Catalogue Number: A9FDB616

Specifications

hide show
Package 1 Height
0.87 dm
Package 1 Length
1 dm
Package 1 width
0.4 dm
Circuit breaker application
distribution
Range of product
Acti 9
Range
Acti 9
Product name
Acti 9 iDPN N Arc
Product or component type
arc fault detection circuit breaker
Product specific application
fire prevention by arc detection
Standards
  • EN/IEC 62606
  • IEC 60898-1
    • Device short name
      iDPN N Arc
      Poles description
      1P + N
      [In] rated current
      16 A at 30 °C
      Curve code
      C
      Breaking capacity
      6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 60898
      Network type
      AC
      Neutral position
      left
      Trip unit technology
      thermal-magnetic
      Number of protected poles
      1
      Network frequency
      50 Hz
      [Ue] rated operational voltage
    • 230 V AC 50 Hz conforming to IEC 62606
    • 230 V AC 50 Hz conforming to EN/IEC 60898-1
      • Device location in system
        outgoer
        Magnetic tripping limit
        5...10 x In
        Limitation class
        3 conforming to IEC 60898-1
        Threshold tripping voltage
        400 V 200 ms
        [Uimp] rated impulse withstand voltage
        4 kV conforming to IEC 60898-1
        [Ui] rated insulation voltage
        400 V AC
        Contact position indicator
        yes
        Control type
        toggle
        Local signalling
        ON, OFF, fault trip
        Mounting mode
        clip-on
        Mounting support
        DIN rail
        Mechanical durability
        20000 cycles
        Electrical durability
        20000 cycles 230 V AC 50 Hz conforming to EN 60898
        Overvoltage category
        III
        Cable entry
        top
        Connections - terminals
      • tunnel type terminal for 1 cable(s) 10-10 mm² flexible
      • tunnel type terminal for 2 cable(s) 2.5-2.5 mm² flexible
      • tunnel type terminal for 1 cable(s) 16-16 mm² rigid
      • tunnel type terminal for 2 cable(s) 2.5-2.5 mm² rigid
        • Wire stripping length
          14 mm
          Tightening torque
          2-2 N.m
          Comb busbar and distribution block compatibility
        • ProDis
        • Librio
          • Connection pitch
            9 mm pitches
            4
            Height
            81 mm
            Width
            36 mm
            Depth
            72 mm
            Net weight
            190 g
            Heat dissipation
            4.18-4.18 W at 230 V - 16 A
            IP degree of protection
            IP20
            Pollution degree
            2
            Tropicalisation
            severity B conforming to IEC 60068-2-30 for 28 d
            Operating altitude
            2000 m
            Ambient air temperature for operation
            -25-60 °C
            Ambient air temperature for storage
            -40-85 °C
            Product certifications
            RCM
            Package 1 Weight
            0.128 kg
            Sustainable offer status
            Green Premium product
            REACh Regulation
            Free of Substances of Very High Concern above the threshold
            EU RoHS Directive
            Compliant
            Mercury free
            Yes
            RoHS exemption information
            Yes
            China RoHS Regulation
            Product out of China RoHS scope. Substance declaration for your information
            Environmental Disclosure
            ENVPEP1312033EN
            Circularity Profile
            ENVEOLI1312033EN
            WEEE
            The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

            Documents & downloads

            hide show

            Frequently Asked Questions

            hide show

            What are the codes for the Fault Arc Detection Devices?

            The part numbers for the Fault Arc Detection Devices are as follows.
            6A - A9FDB606
            10A - A9FDB610
            16A - A9FDB616
            20A - A9FDB620
            25A - A9FDB625

            What is the code for a 10kA 16A 1p C Curve MCB?

             The code is A9F54116

            What is the alternative Acti 9 part code for the discontinued Multi 9 24674?

            The alternative Acti 9 conversion is the A9F45316   3 Pole 16A 6kA MCB 

            What code is the Acti9 equivalent of the Merlin Gerin 25817?

            The Acti9 A9F44216 is a 2p 16A C curve 6kA MCB.
             

            Is there an alternative for a 1 module RCD-MCB part number 4RCBE116/30D?

            Yes, however it is larger in size as it requires 4 modules. The replacement part numbers are A9F55116 + A9V02663.

            What is the difference between A9D32620 and A9D33620 RCBO Acti 9 devices?

             
             

            A9D33620 = SI (Super Immunised)
            A9D32620 = Type A (AC or pulsating DC)

            Type A RCBO = Tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising.
            Type Si RCBO = With all the features of a Type A device, “Si” type Super Immunised earth leakage protection range has been specially developed to be used with loads or in environments causing disturbances. Examples are lightning or switching surges, harmonics generated by increasing number of loads and constant load leakage current from electronic ballasts, speed drives, computers, etc. The Si increases safety and allows improved continuity of supply.
             