sock swt mech dp 10a p/mnt

SWITCHED SOCKET MECHANISM DOUBLE POLE 10A P/MNT

Catalogue Number: 10MDP
sock swt mech dp 10a p/mnt
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE 1

Specifications

hide show
Range of product
Standard Series
Product brand
Clipsal
Quantity per set
set of 1
Cover type
complete housing
Marking
without marking
Local signalling
without light indicator
Device mounting
flush
Fixing mode
by screws
[In] rated current
10 A
[Ue] rated operational voltage
250 V AC
Depth
33 mm
Length
43 mm
Width
42 mm
Fixing center
84 mm
Number of poles
2
Standards
  • AS/NZS 3100
  • AS/NZS 3112
  • AS/NZS 3133:approval number S/1
    • EU RoHS Directive
      Compliant
      Environmental Disclosure
      ENVPEP130201EN
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • CAD Files and Packs

      • Installation Instruction

      • Product Environmental

      • Specifications

      • Certificates (MSDS)

      Frequently Asked Questions

      hide show

      What is the part number of the replacement sockets for CFFB?

      10MDP is the part number of the replacement socket to suit CFFP.
      For further information on 10MDP, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=10MDP

      What is the part number for the FACIA only for the 10MP?

      The part number for the FACIA only for the 10MP is done as a special - 10MPFACIA

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=10MP%20FACIA

      Can the 10MDP be purchased in black ?

      10MDP are not available as a standard part in black but can be ordered as a special. This will need to be quoted and there is a minimum Quantity buy of 50.

      What is the part code for a RCBO 32amp 10m/a

       The part code is 4RCBE232/10

      What size cable will the T100-BK terminals accomodate?

      10mm2 to 50mm2

      Is there a 2 Pole, 10A, 10mA, RCBE?

      Yes, the part number for a 2 Pole, 10A, 10mA, RCBE is a 4RCBE210/01.

      What are the contact ratings for a XCSDMC5912

      Rated operational characteristics - Ue: 24v DC Ie :100mA rated insulation voltage UI ; 100DC

      What is the part code for an RCBO 10mAmp 20Amp needed for a school

       The part code is a 4RCBE220/10.

      Is 2 pole 40A 10mA RCD available?

      No. Unfortunately, the part number is not available in 10mA.

      Whats the part number for a 10mA, 20A RCD MCB?

      The part name is 4RCBE220/10S

      Is there a RCBO with a 16A, 10mA, 10kA rating?

      The part number is a 4RCBE216/10.

      What is the life cycle of the 30MBP?

      The 30MBP has been tested to 12000 cycles.

      Which Clipsal 30 Series mechs are available in 3S (Chrome Shadow)

      Part codes which are available in 3S -  30M, 30USM, 30MI, 30MD, 30MBPR, 30M35, 32E450UDM, 32E450LM, 32E450TM 

      Can a Clipsal 30MD20 be used as a changeover switch?

       No - It is just a 2 pole switch
      But a 30MD2 is a 2p 2way (6 terminals)

      Is there a Double Pole mech in the Saturn range?

      No, but you can use a 4031VH and a 30MD.

      Is there an alternative to a 30MBP momentary bell press mechanism?

      The closest alternative to a 30MBP momentary bell press mechanism is a 30PBBP.
      The older unit was 15A compared to the new version at 16A. The 30PBBP has a square body but mechanically they are the same operation

      Can you purchase just the round piece from the 10MP?

      No, unfortunately the 10MP comes as a  two part unit and the components are not sold seperatly. 

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=10MP
       

      is the 30MBP available in Green or Red?

      Both Colours are not available for that Part.

      Does the ATV212 drive have 10Vdc internal power supply?

      Issue:
      Does the ATV212 drive have 10Vdc internal power supply?

      Producl Line:
      Altivar ATV212

      Environment:
      All

      Cause:
      Customer wanted to know if drive has 10Vdc so that he can test VIA 0-10V signal on the drive without using his 0-10Vdc analog signal from PLC.

      Resolution:
      The internal power supply on the ATV212 is at terminal PP.

      What is part number for ESP series RCD/MCB 20A 10mA?

      The part number for ESP series is a - E02/20/2

      For more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=E02/20/2


      User-added image

      What is the 15 amp version of the 10DWP?

      The 15 amp version of the 10DWP is the 10DWP15.

      For more information, please refer to the link:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=10DWP15

      What is the noise level in dB from the buzzer in the XUJB06031H60 photoelectric sensor?


      The db level of the buzzer is 100db at 1cm.


       

      What is the max current rating on the ATV61 and ATV71 drives 10vdc power supply?

      Issue:
      What is the max current rating on the ATV61 and ATV71 drives 10vdc power supply?

      Product Line:
      Altivar ATV61 and ATV71

      Environment:
      All

      Cause:
      Needs to connect some small LEDs using the 10vdc supply so they need to know the max current current ratings.

      Resolution:
      The max current rating  is 10mA max @ 10vdc.
       

      What is part number for 10amp round flush inlet socket?

      The part number for 10amp round  flush inlet  socket is 435A

      What is part number for din rail 10amp single switched socket?

      The part number for din rail 10amp single switched socket is 4SSO15.

      What is the part number for a PDL 56 Series switch with a 10amp changeover

      It is not available in 10amp version, you can use PDL 56SW120CO which is a 20 amp version.

      What is the part no for 10amp PDL mech?

      The part no for the mech is 687M10WH

      Is the PDL58 socket with brackets 10amp available?

      No, this is a discontinued item and we have no stock left

      Is there a double pole mech of 10amp for the Saturn series?

      The part number 30MD into 4031VH  to 4036VH plates.

      What is the part code for a 3P B-curve 10Amp MCB

       The part code is 18416

      What is the part code for a Prestige twin socket 10Amp 240V

      Use a P2025/2-WE

      What is the part number for a DIN rail Mounted socket outlet?

      10amp = 4SSO15D

      What is the part number for a 2 pole 10amp iC60 C/B?

      The part number for a 2 pole 10amp iC60 C/B is - A9F44210
      For further information , visit link below:-

      https://www.schneider-electric.com.au/en/search/A9F44210
       

      What is the part number for a 2 pole 10amp Acti9 10kA C-Curve C/B?

      The part number for a 2 pole 10amp Acti9 10kA C-Curve C/B is - A9F54210
      For further information , visit link below:-
      https://www.schneider-electric.com.au/en/search/A9F54210
       

      What is the part number for a 10amp caravan power inlet?

      The part number for a 10amp caravan power inlet is - 435

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=435
      User-added image

      What is the part number for a 3 phase 10amp D-Curve RCBO?

      The part number for a 3 phase 10amp D-Curve RCBO is - A9F55310 & A9V02763

      For further information , visit link below:-
      https://www.schneider-electric.com.au/en/search/A9F55310
      https://www.schneider-electric.com.au/en/search/A9V02763

      What is the part number for a 2 pole 10amp D-Curve C/B?

      The part number for a 2 pole 10amp D-Curve C/B is - A9F55210

      For further information , visit link below:
      https://www.schneider-electric.com.au/en/search/A9F55210
       

      What is the part number for a 10amp RCBO , slim type?

      The part number for a 10amp RCBO , slim type is - RCBE210/30S

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=RCBE210/30S
      User-added image

      What is the part number for a 1 pole 10amp 10kA Square D C/B?

      The part number for a 1 pole 10amp 10kA Square D C/B is - QO110VSC10

      For further information , visit link below:-
      https://www.schneider-electric.com.au/en/search/QO110VSC10
       

      What is part number for 10amp plastic strip connector?

      The part number for 10amp plastic strip connector is a BP539P

      For more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=BP539


      User-added image

      What is the part number for a Square D 3 phase 10amp C/B?

      The part number for a Square D 3 phase 10amp C/B is - QO310VSC10

      For further information, visit the link below:-
      https://www.schneider-electric.com.au/en/search/QO310VSC10

       

      What is part number for 10amp double pole weatherproof with flap?

      The part number for 10amp double pole weatherproof with flap is a - 10DWP.

      What is the part number for a 250VAC 10amp foot switch?

      The part number for a 250VAC 10amp foot switch is - 360-WE

      For further information, visit the link below:-
      https://www.clipsal.com/Trade/search-results?q=360
      User-added image

      How do you program ATV61 / ATV71 drive to follow an external 0 to 10vdc speed reference on AI1 input? 

      Issue: 
      How do you program ATV61 drive to follow an external 0 to 10vdc speed reference on AI1 input? 

      Product Line:
      ATV61  ATV71 

      Environment
      All serial numbers

      Cause:
      Using an external speed reference 

      Resolution
      Enter the Main Menu
      Enter the Drive Menu
      Enter the Command menu, 
      Set "Reference 1 ch"  to AI1 
      Goto the  Application Function Menu, 
      Enter Reference switching
      Set reference 1B switching to "channel 1 active"

      Why does the Analog output AO1 not deliver 10Vdc at 60 hz on ATV12 drive?

      Issue:
      Why does the Analog output AO1 not deliver 10Vdc at 60 hz?

      Product Line:
      ATV12

      Environment:
      All

      Cause:
      Output is configured for Motor frequency and 0-10Vdc.

      Resolution:
      The tFr parameter must be set to 60 hz. The Analog output is scaled between 0 to Max Frequency (tFr).

      What is the difference between Normal Duty versus Heavy Duty for the Altivar Process Drive?

      Issue:
      Altivar Process Drive understanding Normal vs Heavy Duty?

      Product Line:
      Altivar Process Drive (ATV630, ATV930, ATV650, ATV950, ATV660, ATV960, ATV680, ATV980)

      Environment:
      All of the Altivar Process Drives

      Cause:
      None

      Resolution:

      Explanation
      The main difference lies within the overload capability of the drive. This setting adjusts the drives current limitations. 
      The "Current Limitation" limits your current based on the overload capability setting of the drive for a maximum time frame of 60s.
      Typically this is your initial starting current
      The drive overload capability can be changed by adjusting the "Dual Rating" parameter in the drive (under menu 5.2 Motor Parameters). There are 2 different settings: Normal Duty / Normal Rating and Heavy Duty / High rating.

      To access the parameter:
      [Complete settings] [Motor parameters] [Dual Rating] drt

      Overload Capability
      ATV600:
      ND +10% (Current Limitations up to 110% of rated current)
      HD +50% (Current Limitations up to 150% of rated current)

      ATV900:
      ND +20% (Current Limitations up to 120% of rated current)
      HD +50% (Current Limitations up to 150% of rated current)

      Understand that when changing the overload capability from normal duty to heavy duty you are de rating the drive to a lower hp size.
      Example below:
      ATV630D75N4
      ND +10% (110%) = Drive Rating of 100hp @ 480 Vac
      HD +50% (150%) = Drive Rating of 75hp @ 480 Vac


      Tips:
      When doing a drive selection, its always a good idea to choose a heavy duty drive if you are not certain the Normal Duty rating will be sufficient.
      Use the links below to access the ATV630 and ATV930 installation manuals and look in the Technical Data section under Electrical Data to find the details on Normal Duty and Heavy Duty.

      ATV630 Installation Manual:  https://www.schneider-electric.com/en/download/document/EAV64301/
      ATV930 Installation Manual:  https://www.schneider-electric.com/en/download/document/NHA80932/

      Is there a red vertical, 10mA, 20A RCD available.

      Yes, the 2031RCD10-RD is the red RCD and can be mounted either vertical or horizontal.

      Some of the key features are:
      • Frequency rating: 50 Hz
      • 10 mA max tripping current
      • Temperature: -10 to 40 deg C
      • Style 2
      • 84 mm mounting centres
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031RCD10.
       

      2031VETR3 - is it an intermediate switch? Can it be used in a stairwell to control a load from three floors?

      2031VETR3 is three wire switch. 
      Additional switches, 30mbp or the 30pbbp, can be installed in parallel to activate the timer from more than one location.

      Please go to the website via the following link www.clipsal.com/Trade/Products/ProductDetail and check under the Documentation Tab for more information.
       

      What is the amp rating on the 30MBP?

      The amp rating on the bell press switch mechanism 30MBP is 15A.
      Some of the key features are:
      • Offers facility for momentary on or off
      • Alternative lamp voltages available
      • Neon is connected across terminals 1 and 4
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=30MBP


       

      Which type of switch should be used for the RemoteTest/Hush feature on the 755PSMA2 Smoke alarm?

      Any 240V momentary switch, such as a 30MBP Bell Press Switch can be wired to either of the two new mounting bases 755RB or 755RFB up to 20m away. A relay can also be pulsed on momentarily via a security or home automation panel to activate the test/hush function. 

      Show More